When the ignition switch is turned to ON, the battery voltage is applied to the IGSW terminal of the ECM. The output signal from the MREL terminal of the ECM causes a current to flow to the EFI MAIN relay coil, closing the EFI MAIN relay contacts and supplying power to terminal +B and +B2 of the ECM.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
After turning ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
| *a | Front view of wire harness connector
(to No. 1 Integration Relay) |
Remove the No. 1 integration relay connector from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1C-1 - Body ground | Always | 11 to 14 V |
OK
NG
Inspect the No. 1 integration relay (See page Engine / Hybrid System>2NZ-FE ENGINE CONTROL>INTEGRATION RELAY>INSPECTION).
OK
NG
Remove the No. 1 integration relay from the engine room relay block.
Disconnect the A83 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A83-46 (MREL) - 1D-7 | Always | Below 1 Ω |
| A83-2 (+B) - 1E-4 | Always | Below 1 Ω |
| A83-3 (+B2) - 1E-4 | Always | Below 1 Ω |
| A83-46 (MREL) or 1D-7 - Body ground | Always | 10 kΩ or higher |
| A83-2 (+B) or 1E-4 - Body ground | Always | 10 kΩ or higher |
| A83-3 (+B2) or 1E-4 - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect the B89 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B89-16 (E1) - Body ground | Always | Below 1 Ω |
OK
NG
| *a | Front view of wire harness connector
(to ECM) |
Disconnect the ECM connectors.
Turn the ignition switch assembly to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A83-37 (IGSW) - B89-16 (E1) | Ignition switch ON | 11 to 14 V |
| Result | Proceed to |
|---|---|
| NG | A |
| OK | B |
A
B
Remove the No. 1 integration relay from the engine room main relay block.
Disconnect the A83 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A83-37 (IGSW) - 1D-9 | Always | Below 1 Ω |
| A83-37 (IGSW) or 1D-9 - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the No. 1 integration relay from the engine room relay block.
Disconnect the F13 ignition switch assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1D-17 - F13-6 (IG2) | Always | Below 1 Ω |
| 1E-10 - Body ground | Always | Below 1 Ω |
| F13-6 (IG2) or 1D-17 - Body ground | Always | 10 kΩ or higher |
OK
NG
Inspect the ignition switch assembly (See page Engine / Hybrid System>2NZ-FE STARTING>IGNITION SWITCH>INSPECTION).
OK
NG