DTC P0037 Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2) |
DTC P0038 Oxygen Sensor Heater Control Circuit High (Bank 1 Sensor 2) |
DTC P0141 Oxygen Sensor Heater Circuit Malfunction (Bank 1 Sensor 2) |
DTC P102D O2 Sensor Heater Circuit Performance Bank 1 Sensor 2 Stuck ON |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0037 | The heater current is less than the specified value while the heater is operating (1 trip detection logic). |
|
| P0038 | The heater current is higher than the specified value while the heater is operating (1 trip detection logic). |
|
| P0141 | The cumulative heater resistance correction value exceeds the threshold (2 trip detection logic). |
|
| P102D | The heater current is higher than the specified value while the heater is not operating (1 trip detection logic). | ECM |
| Related DTCs | P0037: Heated Oxygen Sensor Heater (Bank 1 Sensor 2) Open/Short (Low Electrical Current) P0038: Heated Oxygen Sensor Heater (Bank 1 Sensor 2) Open/Short (High Electrical Current) P0141: Heated Oxygen Sensor Heater Performance (Bank 1 Sensor 2) P102D: Heated Oxygen Sensor Heater ON Stuck (Bank 1 Sensor 2) |
| Required Sensors/Components (Main) | Heated oxygen sensor heater (bank 1 sensor 2) |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous: P0037, P0038, P102D Once per driving cycle: P0141 |
| Duration | 0.5 seconds: P0037 Within 3 seconds: P0038 10 seconds: P0141 0.5 seconds: P102D |
| MIL Operation | Immediate: P0037, P0038, P102D 2 driving cycles: P0141 |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | None |
| Battery voltage | 10.5 V or higher |
| Engine | Running |
| Starter | OFF |
| Catalyst active air fuel ratio control | Not operating |
| Time after heater ON | 10 seconds or more |
| Learned heater OFF current operation | Completed |
| Learned heater OFF current operation | Succeeded |
| Heater ON current - Learned heater OFF current | 0.15 A or less |
| Command to heater output | ON |
| Heated oxygen sensor heater high current fail (P0038) | Not detected |
| Monitor runs whenever following DTCs not present | None |
| Battery voltage | 10.5 V or higher |
| Engine | Running |
| Starter | OFF |
| Catalyst active air fuel ratio control | Not operating |
| Time after heater ON | 10 seconds or more |
| Learned heater OFF current operation | Completed |
| Heater OFF current | Higher than 3.5 A |
| Heater monitor IC high current limiter monitor input | Fail |
| Heated oxygen sensor heater low current fail (P0037) | Not detected |
| Heated oxygen sensor heater high current fail (P0038) | Not detected |
| Monitor runs whenever following DTCs not present | None |
| Battery voltage | 10.5 V or higher |
| Engine | Running |
| Starter | OFF |
| Catalyst active air fuel ratio control | Not operating |
| Time after heater ON | 10 seconds or more |
| Learned heater OFF current operation | Completed |
| Monitor runs whenever following DTCs not present | None |
| Heated oxygen sensor heater circuit fail (P0037, P0038 and P102D) | Not detected |
| Battery voltage | 10.5 V or higher |
| Fuel cut | OFF |
| Time after fuel cut ON to OFF | 30 seconds or more |
| Accumulated heater ON time | 100 seconds or more |
| Learned heater OFF current operation | Completed |
| Active heater OFF control | Not operating |
| Active heater ON control | Not operating |
| Duration that rear heated oxygen sensor impedance is less than 15 kΩ | 2 seconds or more |
| Heater monitor IC high current limiter monitor input | Pass |
| Monitor runs whenever following DTCs not present | None |
| Battery voltage | 10.5 V or higher |
| Engine | Running |
| Starter | OFF |
| Catalyst active air fuel ratio control | Not operating |
| Time after heater ON | 10 seconds or more |
| Heated oxygen sensor heater low current fail (P0037) | Not detected |
| Heated oxygen sensor heater high current fail (P0038) | Not detected |
| Heater ON current - Learned heater OFF current | 0.15 A or less |
| Heated oxygen sensor heater ON current | 1 A or less |
| Heater monitor IC high current limiter monitor input | Fail |
| Command to heater output | ON |
| Accumulated heater resistance | Varies with sensor element temperature (Example: Higher than 23 Ω) |
| Heater ON current | Higher than 1 A |
| Heated oxygen sensor heater current | 0.4 to 1 A (when engine idles, heated oxygen sensor warmed up and battery voltage 11 to 14 V) |
| Monitor ID | Test ID | Scaling | Unit | Description |
| $42 | $91 | Multiply by 0.001 | Ohm | Oxygen sensor heater resistance bank 1 sensor 2 |

| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|
| 1.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE) |
Inspect the heated oxygen sensor (Click here).
|
| ||||
| OK | |
| 2.INSPECT TERMINAL VOLTAGE (POWER SOURCE OF HEATED OXYGEN SENSOR) |
![]() |
Disconnect the heated oxygen sensor connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D145-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Heated Oxygen Sensor) |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM) |
Disconnect the heated oxygen sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D145-1 (HT1B) - C51-22 (HT1B) | Always | Below 1 Ω |
| D145-1 (HT1B) or C51-22 (HT1B) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 4.CHECK WHETHER DTC OUTPUT RECURS (DTC P0037, P0038, P0141 OR P102D) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Clear the DTCs (Click here).
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON.
Turn the Techstream on.
Start the engine.
Drive the vehicle in accordance with the driving pattern described in Confirmation Driving Pattern.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read pending DTCs.
| Result | Proceed to |
| DTC is not output | A |
| DTC P0037, P0038, P0141 or P102D is output | B |
|
| ||||
| A | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - NO. 1 INTEGRATION RELAY) |
Disconnect the heated oxygen sensor connector.
Remove the No. 1 integration relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D145-2 (+B) - 1D-11 | Always | Below 1 Ω |
| D145-2 (+B) or 1D-11 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||