Home › Engine / Hybrid System › 2NR-FE INTAKE / EXHAUST › EXHAUST MANIFOLD › 2017.10–2018.01
RM30M0E _51 Engine / Hybrid System _053549 2NR-FE INTAKE / EXHAUST _0265585 EXHAUST MANIFOLD A

2NR-FE INTAKE / EXHAUST  EXHAUST MANIFOLD  REMOVAL  


PROCEDURE

Hide 27020 1.REMOVE GENERATOR WITH REGULATOR ASSEMBLY

Hide 53141F 2.REMOVE RADIATOR COVER (for TMMIN Made)

Hide 53141F 3.REMOVE RADIATOR COVER (for TMT Made)

Hide 89467B 4.REMOVE AIR FUEL RATIO SENSOR

Hide 17168 5.REMOVE NO. 2 EXHAUST MANIFOLD HEAT INSULATOR

a.
A313689

Remove the 3 bolts and No. 2 exhaust manifold heat insulator from the exhaust manifold converter sub-assembly.


Hide 17410 6.DISCONNECT FRONT EXHAUST PIPE ASSEMBLY

a.
A382998C02
0.167,0.167 0.406,0.365 0.24,0.198 12 true *A 0.167,2.458 0.417,2.667 0.25,0.208 12 true *B
*A for CVT
*B for Manual Transaxle


Disconnect the heated oxygen sensor connector.


b.

Disengage the clamp to disconnect the heated oxygen sensor wire from the wire harness clamp bracket.


c.

Remove the 2 bolts and 2 compression springs to disconnect the front exhaust pipe assembly from the exhaust manifold converter sub-assembly.


Hide 17118 7.REMOVE MANIFOLD STAY

a.
A313691

Remove the bolt, nut and manifold stay from the exhaust manifold converter sub-assembly and cylinder block sub-assembly.


Hide 25051 8.REMOVE EXHAUST MANIFOLD CONVERTER SUB-ASSEMBLY

a.
A313692

Remove the 5 nuts and exhaust manifold converter sub-assembly from the cylinder head sub-assembly.


b.
A313693

Remove the exhaust manifold to head gasket from the cylinder head sub-assembly.


c.