Home › Vehicle Exterior › WINDOW / GLASS › POWER WINDOW CONTROL SYSTEM › 2017.10–2018.01
RM30M0E _59 Vehicle Exterior _017121 WINDOW / GLASS _0086434 POWER WINDOW CONTROL SYSTEM J

WINDOW / GLASS  POWER WINDOW CONTROL SYSTEM  Auto Up Operation does not Fully Close Power Window (Jam Protection Function is Activated)  


DESCRIPTION

If a door glass or a front power window regulator motor assembly (driver side) does not operate smoothly, the jam protection function may be triggered automatically, resulting in the auto up function being unable to fully close the window.

HINT:

This symptom may occur only in the driver side window.


NOTICE:
·

When the front power window regulator motor assembly RH is reinstalled or replaced, the power window control system must be initialized.

·

Replacing the door glass or door glass run may cause a difference to exist between the current door glass position and the position memorized in the ECU. In this case, the jam protection function may work improperly. Return the system to the pre-initialized condition and reinitialize the system.

1.

Disconnect the power window regulator motor connector during power window operation. This will return the motor to the pre-initialized condition.

HINT:

The auto up function will not work unless initialization is completed.





PROCEDURE

1.PERFORM INITIALIZATION (for DRIVER SIDE)
a.

Initialize the front power window regulator motor assembly (driver side).

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM>INITIALIZATION


Result:
Proceed to
NEXT



NEXT

2.CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION (for DRIVER SIDE))
2.CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION (for DRIVER SIDE))
a.

Check that the driver side door power window moves when the auto up and down function of the power window regulator master switch assembly and are operated.

for TMMIN made: Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW MASTER SWITCH(for TMMIN Made)>INSPECTION

for TMT made: Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW MASTER SWITCH(for TMT Made)>INSPECTION

OK:

Auto up and down function is normal (for driver side).



Result:
Proceed to
OK
NG



OK

END (PROBLEM DUE TO INITIALIZATION FAILURE)

NG

3.CHECK WINDOW GLASS SLIDING MOVEMENT (for DRIVER SIDE)
3.CHECK WINDOW GLASS SLIDING MOVEMENT (for DRIVER SIDE)
a.

Remove the door window regulator.


b.

Install the window glass onto the door glass run.


c.

Check if the door window regulator operates smoothly.


d.

Check that the window glass slides smoothly when sliding it up by hand.

OK:

Door window glass slides smoothly.


HINT:

Ensure the following:

·

The window glass fits with the glass run without improper contact or deformation.


·

Foreign objects are not caught in the glass run.



CAUTION:

Perform initialization again.



Result:
Proceed to
OK
NG



OK

REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH OR RH

NG

FIT WINDOW GLASS CORRECTLY (REMOVE FOREIGN OBJECTS CAUSING IMPROPER FIT OR REPLACE PARTS)