MALFUNCTION DESCRIPTION
The hybrid vehicle control ECU detects malfunctions which prevent the inverter with converter assembly emergency shutdown circuit (HSDN) from shutting down the hybrid control system. Detection is performed when the ignition switch is turned to ON and during the shutdown sequence when the ignition switch is turned off.
The cause of this malfunction may be one of the following:
Hybrid vehicle control ECU malfunction
Connector or wire harness malfunction (between hybrid vehicle control ECU and inverter with converter assembly) malfunction
Inverter with converter assembly malfunction
The hybrid vehicle control ECU sends a block signal to the motor generator control ECU (MG ECU) to shutdown the power supply to the motor. When the system is not in the on (READY) state, it sends an HSDN (MG shutdown signal) signal from the hybrid vehicle control ECU to the motor generator control ECU (MG ECU) to check the function of the HV gate block. When a malfunction is detected in the HV gate block function, DTCs are stored.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P321E9F | Motor/Generator Shutdown Signal Stuck Off | When the HV gate block function check is performed (when the ignition switch is turned from ON (READY) to off), the inverter voltage (VH) drops and current flows in the inverter.
(1 trip detection logic) |
·
Wire harness or connector ·
Hybrid vehicle control ECU ·
Inverter with converter assembly |
Does not come on | Master Warning: Comes on |
| DTC No. | Data List |
|---|---|
| P321E9F | ·
VH-Voltage after Boosting ·
Ready Signal ·
Inverter Emergency Shutdown (Main CPU) ·
Inverter Emergency Shutdown (Sub CPU) |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON (READY) and wait for 30 seconds or more.
Turn the ignition switch off and wait for 2 minutes or more.
Turn the ignition switch to ON (READY) and wait for 30 seconds or more.
Turn the ignition switch off and wait for 2 minutes or more.
Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
Refer to the wiring diagram for the shut down signal circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Shut Down Signal Circuit
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P321E9F is output | A |
| P321E9F and DTCs other than the DTCs in the table below are output | B |
| P321E9F and any DTCs in the table below are output | C |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Sensor and actuator circuit malfunction | P33B99F | Motor/Generator Shutdown Signal (Hybrid/EV Side) Stuck Off |
| P33BF9F | Motor/Generator Shutdown Signal (MG Side) Stuck Off | |
P321E9F may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P056014
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P033500
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector) | C |
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A56 inverter with converter assembly connector.
Disconnect the A68 hybrid vehicle control ECU connector.
Procedure1
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector
(to Hybrid Vehicle Control ECU) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A56-22 (HSDN) - A68-9 (HSDN) | Ignition switch off | Below 1 Ω |
| A56-22 (HSDN) or A68-9 (HSDN) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
As there might be an intermittent malfunction, inspect the following items even if the measured resistance is as specified.
Check that each connector between the inverter with converter assembly and hybrid vehicle control ECU is not loose or disconnected.
Post-procedure1
Reconnect the A68 hybrid vehicle control ECU connector.
Reconnect the A56 inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the A56 inverter with converter assembly connector.
Procedure1
| *a | Component without harness connected
(Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A56-22 (HSDN) - A56-24 (GND1) | Ignition switch off | 2.65 to 3.55 kΩ |
Be sure not to damage or deform the terminal being inspected.
Post-procedure1
Reconnect the A56 inverter with converter assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG