The air conditioning harness assembly and No. 1 air conditioning radiator damper servo sub-assembly connect the air conditioning amplifier assembly and the No. 1 blower damper servo sub-assembly. The air conditioning amplifier assembly supplies power and sends operation instructions to No. 1 blower damper servo sub-assembly through the air conditioning harness assembly and No. 1 air conditioning radiator damper servo sub-assembly. The No. 1 blower damper servo sub-assembly sends pulse signals to inform the air conditioning amplifier assembly of the damper position.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory |
|---|---|---|---|---|
| B143A87 | Lost Communication with Air Inlet Damper Control Servo Motor LIN Missing Message | Diagnosis Condition:
Ignition switch ON Malfunction Status: Error or lost communication with No. 1 blower damper servo sub-assembly Detection Time: Continuously for 10 seconds or more |
·
No. 1 blower damper servo sub-assembly ·
Air conditioning harness assembly |
Memorized |
| Vehicle Condition | |||
|---|---|---|---|
| Pattern 1 | Pattern 2 | ||
| Diagnosis Condition | Ignition switch ON | ○ | ○ |
| Malfunction | Error communication with No. 1 blower damper servo sub-assembly | ○ | - |
| Lost communication with No. 1 blower damper servo sub-assembly | - | ○ | |
| Detection Time | Continuously for 10 seconds or more | Continuously for 10 seconds or more | |
| Trip Count | 1 trip | 1 trip | |
If the conditions of either of these patterns are detected, a DTC will be stored.
for Dual Type
for Single Type
Check for DTCs.
| Result | Proceed to |
|---|---|
| B142A88 is output | A |
| B142A88 is not output | B |
A
B
Choose the model to be inspected.
| Result | Proceed to |
|---|---|
| for LHD | A |
| for RHD | B |
A
B
Pre-procedure1
Disconnect the h7 No. 1 air conditioning radiator damper servo sub-assembly connector.
Disconnect the h4 No. 1 blower damper servo sub-assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| h7-1 (M-) - h4-5 (M-) | Always | Below 1 Ω |
| h7-2 (M+) - h4-4 (M+) | Always | Below 1 Ω |
| h7-3 (STE2) - h4-3 (sigB) | Always | Below 1 Ω |
| h7-4 (STE1) - h4-2 (sigA) | Always | Below 1 Ω |
| h7-5 (GND) - h4-1 (GND) | Always | Below 1 Ω |
| h7-1 (M-) or h4-5 (M-) - Other terminals and body ground | Always | 10 kΩ or higher |
| h7-2 (M+) or h4-4 (M+) - Other terminals and body ground | Always | 10 kΩ or higher |
| h7-3 (STE2) or h4-3 (sigB) - Other terminals and body ground | Always | 10 kΩ or higher |
| h7-4 (STE1) or h4-2 (sigA) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Disconnect the h7 No. 1 air conditioning radiator damper servo sub-assembly connector.
Disconnect the h4 No. 1 blower damper servo sub-assembly connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| h7-1 (M-) - h4-5 (M-) | Always | Below 1 Ω |
| h7-2 (M+) - h4-4 (M+) | Always | Below 1 Ω |
| h7-3 (STE2) - h4-3 (sigB) | Always | Below 1 Ω |
| h7-4 (STE1) - h4-2 (sigA) | Always | Below 1 Ω |
| h7-5 (GND) - h4-1 (GND) | Always | Below 1 Ω |
| h7-1 (M-) or h4-5 (M-) - Other terminals and body ground | Always | 10 kΩ or higher |
| h7-2 (M+) or h4-4 (M+) - Other terminals and body ground | Always | 10 kΩ or higher |
| h7-3 (STE2) or h4-3 (sigB) - Other terminals and body ground | Always | 10 kΩ or higher |
| h7-4 (STE1) or h4-2 (sigA) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG