The Variable Valve Timing (VVT) system includes the ECM, camshaft timing oil control valve assembly and VVT controller. The ECM sends a target "duty-cycle" control signal to the camshaft timing oil control valve assembly. This control signal, applied to the camshaft timing oil control valve assembly, regulates the oil pressure supplied to the VVT controller. Camshaft timing control is performed based on engine operating conditions such as intake air volume, throttle position and engine coolant temperature.
The ECM controls the camshaft timing oil control valve assembly based on the signals from several sensors. The VVT controller regulates the exhaust camshaft angle using oil pressure through the camshaft timing oil control valve assembly. As a result, the relative positions of the camshaft and crankshaft are optimized, engine torque and fuel economy improve, and the exhaust emissions drop. The ECM detects actual valve timing using signals from the camshaft and crankshaft position sensors. The ECM performs feedback control and verifies target valve timing.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P001311 | "B" Camshaft Position Actuator "A" Control Circuit/Open Bank 1 Circuit Short to Ground | Short to ground in camshaft timing oil control valve (for exhaust camshaft) circuit (VVT OCV low side drive circuit) (3 trip detection logic) | ·
Open or short in camshaft timing oil control valve assembly (for exhaust camshaft) circuit ·
Camshaft timing oil control valve assembly (for exhaust camshaft) ·
ECM |
Comes on | DTC stored | Engine | A |
| P001312 | "B" Camshaft Position Actuator "A" Control Circuit/Open Bank 1 Circuit Short to Battery | Short to power source line in camshaft timing oil control valve (for exhaust camshaft) circuit (VVT OCV low side drive circuit) (3 trip detection logic) | ·
Open or short in camshaft timing oil control valve assembly (for exhaust camshaft) circuit ·
Camshaft timing oil control valve assembly (for exhaust camshaft) ·
ECM |
Comes on | DTC stored | Engine | A |
| P001313 | Camshaft Position "B" - Actuator Bank 1 Circuit Open | Open in camshaft timing oil control valve (for exhaust camshaft) circuit (VVT OCV low side drive circuit) (3 trip detection logic) | ·
Open or short in camshaft timing oil control valve assembly (for exhaust camshaft) circuit ·
Camshaft timing oil control valve assembly (for exhaust camshaft) ·
ECM |
Comes on | DTC stored | Engine | A |
The IC, built into the ECM, detects opens or shorts in the camshaft timing oil control valve assembly (for exhaust camshaft) circuit.
DTC P001311, P001312 and P001313 are detected when the engine idles for approximately 15 seconds.
After replacing the ECM, perform idle learning.
Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION
Read freeze frame data using the GTS. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Pre-procedure1
Start the engine.
Warm up the engine.
Procedure1
Check the engine speed when operating the camshaft timing oil control valve assembly (for exhaust camshaft) using the GTS.
| Active Test Display |
|---|
| Control the Exhaust VVT OCV Duty Ratio Bank 1 |
| Data List Display |
|---|
| Exhaust VVT Change Angle Bank 1 |
| Exhaust VVT OCV Control Duty Ratio Bank 1 |
| Result | Proceed to |
|---|---|
| Engine changes from steady idling to rough idling or engine stalling | A |
| No change in engine speed | B |
Post-procedure1
None.
A
B
Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>CAMSHAFT OIL CONTROL VALVE>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Disconnect the camshaft timing oil control valve assembly (for exhaust camshaft) connector.
Disconnect the ECM connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D78-2 (+) - D50-73 (OE1+) | Always | Below 1 Ω |
| D78-1 (-) - D50-72 (OE1-) | Always | Below 1 Ω |
| D78-2 (+) or D50-73 (OE1+) - Body ground | Always | 10 kΩ or higher |
| D78-1 (-) or D50-72 (OE1-) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG