Home › Engine / Hybrid System › 1KR-FE (ENGINE CONTROL) › SFI SYSTEM › from 2020.07
RM36W0E _51 Engine / Hybrid System _091054 1KR-FE ENGINE CONTROL _0431746 SFI SYSTEM C

1KR-FE ENGINE CONTROL  SFI SYSTEM  P013012  O2 (A/F) Sensor Circuit Bank 1 Sensor 1 Circuit Short to Battery  


DESCRIPTION

Refer to DTC P013013.

Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>P013013

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory DTC Output from Priority
P013012 O2 (A/F) Sensor Circuit Bank 1 Sensor 1 Circuit Short to Battery

All of the following conditions are met (3 trip detection logic):

(a)

Target lambda*1 is more than 0.995.

(b)

Heated oxygen sensor (sensor 1) output voltage is more than 3.5 V.

(c)

Conditions (a) and (b) are met for 0.5 seconds or more.

(d)

100 seconds have elapsed since condition (c) was met and heated oxygen sensor dew point judgment*2 was completed.



·

Short in signal output circuit and power source circuit of heated oxygen sensor (sensor 1)

·

Heated oxygen sensor (sensor 1)

·

ECM


Comes on DTC stored Engine A

HINT:
·

*1: Target lambda value of the ECM.

-

Target lambda value is 1.0: stoichiometric air-fuel ratio

-

Target lambda value is more than 1.0: lean control performed

-

Target lambda value is less than 1.0: rich control performed


·

*2: Condensation may form in the exhaust pipes after the engine is started and before the exhaust system has warmed up. If condensation exists, the sensor element may be damaged if the heated oxygen sensor (sensor 1) heater is heated excessively. Therefore, the ECM will restrict the output of the heated oxygen sensor (sensor 1) heater until it determines condensation is not forming in the exhaust pipes. Dew point judgment is when the ECM judges that condensation is no longer forming.



WIRING DIAGRAM

CONFIRMATION DRIVING PATTERN

CAUTION:

When performing the confirmation driving pattern, obey all speed limits and traffic laws.


DTC P013012 is detected when the vehicle is driven in an urban area at an average vehicle speed of approximately 50 km/h (31 mph) for approximately 30 minutes.

CAUTION / NOTICE / HINT

NOTICE:

After replacing the ECM, perform idle learning.

Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION


HINT:
·

Sensor 1 refers to the sensor closest to the engine assembly.

·

Sensor 2 refers to the sensor farthest away from the engine assembly.

·

Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.



PROCEDURE

1.INSPECT HEATED OXYGEN SENSOR (SENSOR 1)
A209298C03
1.552,1.417 0.958,1.667 false 1.875,1.063 2.49,0.74 false 0.167,0.146 0.531,0.583 0.365,0.438 10 false *a 0.76,1.698 1.323,2.042 0.563,0.344 10 false OX1A 2.573,0.573 2.927,0.813 0.354,0.24 10 false +B
*a Component without harness connected
(Heated Oxygen Sensor (Sensor 1))


Pre-procedure1

a.

Disconnect the heated oxygen sensor (sensor 1) connector.


Procedure1

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (+B) - 4 (OX1A) Always 10 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

c.

None.



OK

2.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR (SENSOR 1) - ECM)

NG

2.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR (SENSOR 1) - ECM)

Pre-procedure1

a.

Disconnect the heated oxygen sensor (sensor 1) connector.


b.

Disconnect the ECM connector.


Procedure1

c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D38-4 (OX1A) - D50-126 (OX1A) Always 10 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

d.

None.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR