Refer to DTC P060E87.
Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>P060E87
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P211173 | Throttle Actuator "A" Control System Actuator Stuck Closed | The throttle does not open when current is applied to the throttle motor (1 trip detection logic). | ·
Open or short circuit in throttle motor circuit ·
Throttle body with motor assembly |
Comes on | DTC stored | Engine | B |
Refer to DTC P060E87.
Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>P060E87
DTC P21173 is detected when the ignition switch to ON.
After replacing the throttle body with motor assembly, perform electronic throttle learning and idle learning.
Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION
Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Read the DTCs.
| Result | Proceed to |
|---|---|
| Only P211173 is output | A |
| P211173 and other DTCs are output | B |
If any DTCs other than P211173 are output, troubleshoot those DTCs first.
A
B
Pre-procedure1
Remove the throttle body with motor assembly.
Procedure1
Check for contamination between the throttle valve and housing. If necessary, clean the throttle body with motor assembly. Also, check that the throttle valve moves smoothly.
Throttle valve is not contaminated with foreign matter and moves smoothly.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Pre-procedure1
Disconnect the throttle body with motor assembly connector.
Disconnect the ECM connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D50-103 (M+) - D18-6 (M+) | Always | Below 1 Ω |
| D50-135 (M-) - D18-5 (M-) | Always | Below 1 Ω |
| D50-103 (M+) or D18-6 (M+) - Body ground | Always | 10 kΩ or higher |
| D50-135 (M-) or D18-5 (M-) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None.
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for at least 30 seconds.
NEXT
Pre-procedure1
Turn the ignition switch to ON.
Procedure1
Read the DTCs.
DTCs are not output.
| Proceed to |
|---|
| NEXT |
Post-procedure1
None.
NEXT