Home › Engine / Hybrid System › 1KR-FE (ENGINE CONTROL) › SFI SYSTEM › from 2020.07
RM36W0E _51 Engine / Hybrid System _091054 1KR-FE ENGINE CONTROL _0431746 SFI SYSTEM C

1KR-FE ENGINE CONTROL  SFI SYSTEM  P245211  Particulate Filter Pressure Sensor "A" Circuit Short to Ground  


DESCRIPTION

A differential pressure sensor is installed to monitor the pressure before the GPF (Gasoline Particulate Filter) catalyst converter. The sensor is a semiconductor type that is not affected by the exhaust gas. The differential pressure sensor outputs the difference between the atmospheric pressure and the pressure before the GPF catalyst.

A409082E12
1.729,3.375 1.104,3.302 true 1.542,2.469 0.979,2.844 true 2.615,0.323 2.229,0.573 true 2.385,1.115 2.115,1.219 true 0.417,1.052 1.417,1.25 1,0.198 10 false Exhaust Gas 2.646,0.25 3.083,0.49 0.438,0.24 10 false ECM 2,1.833 3.469,2.083 1.469,0.25 10 false Atmospheric Pressure 1.594,2.385 3.292,2.583 1.698,0.198 10 false GPF Catalyst 4.99,3.177 6.385,3.438 1.396,0.26 10 false Pressure (kPa [psi]) 3.813,0.604 4.604,0.854 0.792,0.25 10 false Voltage (V) 4.229,1.25 4.667,1.5 0.438,0.25 10 false 4.65 4.25,1.969 4.688,2.219 0.438,0.25 10 false 0.75 4.25,2.156 4.688,2.406 0.438,0.25 10 false 0.55 4.698,2.51 4.948,2.813 0.25,0.302 10 false -5 4.958,2.51 5.208,2.813 0.25,0.302 10 false 0 6,2.531 6.271,2.823 0.271,0.292 10 false 150 4.938,0.771 6.302,0.99 1.365,0.219 10 false Differential Pressure 2.438,1.052 3.719,1.427 1.281,0.375 10 false Differential Pressure Sensor 4.521,2.792 4.875,3 0.354,0.208 10 false [-0.7] 4.917,2.792 5.271,3 0.354,0.208 10 false [0] 5.948,2.813 6.635,3.031 0.688,0.219 10 false [21.8] 1.813,3.302 4.094,3.583 2.281,0.281 10 false Front Exhaust Pipe Assembly

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory DTC Output from Priority
P245211 Particulate Filter Pressure Sensor "A" Circuit Short to Ground The output voltage from the differential pressure sensor is 0.385 V or less for 0.5 seconds or more (1 trip detection logic).
·

Open or short in differential pressure sensor circuit

·

Differential pressure sensor

·

ECM


Comes on DTC stored (Euro-OBD)
- (except Euro-OBD)
Engine A

HINT:

When a DTC is output, check the Data List item "GPF Differential Pressure Sensor Bank 1" using the GTS.

Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>DATA LIST / ACTIVE TEST

DTC No. GPF Differential Pressure Sensor Bank 1 Malfunction
P245211 Approximately -5 kPa [-0.73 psi]
·

Short in PEX circuit to ground

·

Short in PEX circuit to EPEX circuit

·

Open in VCPX circuit



If the Data List displays a normal value, the normal value may be due to a temporary recovery from the malfunction condition. Check for intermittent problems.


MONITOR DESCRIPTION

In order to detect abnormality in the differential pressure sensor, the ECM always monitors the output voltage from the sensor. When the sensor output voltage deviates from the normal operating range, the ECM interprets this as a malfunction in the sensor circuit.

Example:

When the sensor output voltage is below 0.385 V for 0.5 seconds or more, the ECM stores a DTC.

MONITOR STRATEGY

Frequency of Operation Continuous

CONFIRMATION DRIVING PATTERN

1.

Connect the GTS to the DLC3.

2.

Turn the ignition switch to ON.

3.

Turn the GTS on.

4.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

5.

Turn the ignition switch off and wait for at least 30 seconds.

6.

Turn the ignition switch to ON.

7.

Turn the GTS on.

8.

Start the engine and wait 5 seconds or more.

9.

Enter the following menus: Powertrain / Engine / Trouble Codes.

10.

Read the pending DTCs.


WIRING DIAGRAM

A421608E14
0.229,2.781 0.688,2.979 0.458,0.198 10 false D72 0.229,2.969 2.073,3.271 1.844,0.302 10 false Differential Pressure Sensor 1.135,0.938 1.448,1.135 0.313,0.198 10 false VC 1.458,0.833 1.615,1.031 0.156,0.198 10 false 3 1.188,2.24 1.5,2.438 0.313,0.198 10 false E2 1.448,2.146 1.604,2.344 0.156,0.198 10 false 1 1.073,1.583 1.531,1.781 0.458,0.198 10 false PEX 1.458,1.49 1.615,1.688 0.156,0.198 10 false 2 5.073,3.01 5.385,3.208 0.313,0.198 10 false A55 5.396,3.01 5.854,3.208 0.458,0.198 10 false ECM 4.656,0.844 5.271,1.042 0.615,0.198 10 false VCPX 5.51,0.635 5.969,0.833 0.458,0.198 10 false 5 V 4.417,0.844 4.729,1.042 0.313,0.198 10 false 35 4.396,1.479 4.708,1.677 0.313,0.198 10 false 34 4.656,1.5 5.115,1.698 0.458,0.198 10 false PEX 4.406,2.146 4.719,2.344 0.313,0.198 10 false 32 4.646,2.146 5.26,2.344 0.615,0.198 10 false EPEX 5.458,1.26 6.375,1.458 0.917,0.198 10 false 200 kΩ

CAUTION / NOTICE / HINT

NOTICE:

After replacing the ECM, perform idle learning.

Click hereEngine / Hybrid System>1KR-FE (ENGINE CONTROL)>SFI SYSTEM>INITIALIZATION


HINT:

Read Freeze Frame Data using the GTS. The ECM records vehicle and driving condition information as Freeze Frame Data the moment a DTC is stored. When troubleshooting, Freeze Frame Data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.


PROCEDURE

1.CHECK HARNESS AND CONNECTOR
HINT:

Make sure that the connector is properly connected. If it is not, securely connect it and check for DTCs again.


Pre-procedure1

a.

Disconnect the differential pressure sensor connector.


b.

Turn the ignition switch to ON.


Procedure1

c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
D72-3 (VC) - D72-1 (E2) Ignition switch ON 4.5 to 5.5 V
D72-2 (PEX) - D72-1 (E2) Ignition switch ON 3.0 to 5.5 V



d.

Turn the ignition switch off and wait for at least 30 seconds.


e.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D72-3 (VC) - D72-2 (PEX) Ignition switch off 190 to 210 kΩ



Result:
Proceed to
OK
NG


Post-procedure1

f.

None.



OK

NG

2.CHECK HARNESS AND CONNECTOR (DIFFERENTIAL PRESSURE SENSOR - ECM)
2.CHECK HARNESS AND CONNECTOR (DIFFERENTIAL PRESSURE SENSOR - ECM)

Pre-procedure1

a.

Disconnect the differential pressure sensor connector.


b.

Disconnect the ECM connector.


Procedure1

c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
D72-3 (VC) - A55-35 (VCPX) Always Below 1 Ω
D72-2 (PEX) or A55-34 (PEX) - Body ground and other terminals Always 10 kΩ or higher



Result:
Proceed to
OK
NG


Post-procedure1

d.

None.



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR