The skid control ECU (brake actuator assembly) receives stop light switch assembly signals and uses them to determine whether or not the brakes are applied.
When the brake pedal is depressed and no signal is received from the stop light switch assembly, this DTC is output.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from |
|---|---|---|---|---|
| P057111 | Brake Switch "A" Circuit Short to Ground | Either of the following is detected when the vehicle speed of 3 km/h (2 mph) or more:
1.
With the stop light switch assembly off, the stop light switch assembly is judged to be on based on the master cylinder pressure value for 3 seconds or more. 2.
With the stop light switch assembly off, the master cylinder pressure is more than 8 MPa (81.6 kgf/cm2, 1160 psi) for 3 seconds or more. |
·
Stop light switch assembly ·
Wire harness or connector ·
Skid control ECU (brake actuator assembly) |
Brake |
Inspect the fuses for circuits related to this system before performing the following procedure.
After replacing the skid control ECU (brake actuator assembly), perform acceleration sensor zero point calibration and store system information memorization.
Check the Data List using the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Master Cylinder Sensor 1 | Master cylinder pressure sensor pressure (value detected by ECU) | Min.: -1.00 MPa, Max.: 23.99 MPa | Brake pedal released: -1.00 to 0.00 MPa | Reading increases when brake pedal is depressed |
| Tester Display |
|---|
| Master Cylinder Sensor 1 |
Check the value of Data List item Master Cylinder Sensor 1 when the brake pedal is released.
The value of Data List item Master Cylinder Sensor 1 when the brake pedal is released is less than 0.15 MPa.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Make sure that there is no looseness at the locking part and the connecting part of the connector.
The connector is securely connected.
Disconnect the A39 skid control ECU (brake actuator assembly) connector.
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A39-41 (STP) - Body ground | Brake pedal depressed | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
for RHD: Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>BRAKE ACTUATOR (for HV Model TMMF Made RHD)>REMOVAL
for LHD: Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>BRAKE ACTUATOR (for HV Model LHD)>REMOVAL
NG
Make sure that there is no looseness at the locking part and the connecting part of the connector.
The connector is securely connected.
Disconnect the A39 skid control ECU (brake actuator assembly) connector.
Disconnect the A63 stop light switch assembly connector.
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A63-3 (L) - A39-41 (STP) | Always | Below 1 Ω |
| A63-3 (L) or A39-41 (STP) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Read the DTCs using the GTS.
Check the details of the DTCs.
| Result | Proceed to |
|---|---|
| P057111 and C05401C, C054028 and/or C054049 are output simultaneously | A |
| P057111 is output | B |
A
B
Refer to "Brake drag" of problem symptoms table.
Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE SYSTEM (for HV Model TMMF Made)>PROBLEM SYMPTOMS TABLE