HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System)  B141A15  Room Temperature Sensor Circuit Short to Battery or Open  


DESCRIPTION

The cooler (room temp. sensor) thermistor is installed in the instrument panel to detect the cabin temperature, which is used to control the air conditioning system. The resistance of the cooler (room temp. sensor) thermistor changes in accordance with the cabin temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the cooler (room temp. sensor) thermistor and reads voltage changes due to changes in the resistance of the cooler (room temp. sensor) thermistor.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B141A15 Room Temperature Sensor Circuit Short to Battery or Open Diagnosis Condition:

Ignition switch ON


Malfunction Status:

Open or short in room temperature sensor circuit


Detection Time:

Continuously for 4 seconds or more


·

Cooler (room temp. sensor) thermistor

·

Harness or connector

·

Air conditioning amplifier assembly


Memorized

DTC Detection Condition Combination Table
Vehicle Condition
Pattern 1 Pattern 2
Diagnosis Condition Ignition switch ON ○ ○
Malfunction Open in room temperature sensor circuit ○ -
Short in room temperature sensor circuit - ○
Detection Time Continuously for 4 seconds or more Continuously for 4 seconds or more
Trip Count 1 trip 1 trip

HINT:

If the conditions of either of these patterns are detected, a DTC will be stored


WIRING DIAGRAM

E368742E60
0.188,1.802 0.521,2 0.333,0.198 10 false H58 0.188,1.979 2.677,2.167 2.49,0.188 10 false Cooler (Room Temp. Sensor) Thermistor 4.646,1.802 4.979,2 0.333,0.198 10 false H25 4.656,1.969 7.146,2.156 2.49,0.188 10 false Air Conditioning Amplifier Assembly 2.146,0.667 2.323,0.885 0.177,0.219 10 false 1 2.156,1.156 2.333,1.375 0.177,0.219 10 false 2 4.615,1.156 4.771,1.344 0.156,0.188 10 false 3 4.625,0.667 4.813,0.854 0.188,0.188 10 false 5 4.813,0.677 5.063,0.865 0.25,0.188 10 false TR 4.802,1.156 5.208,1.344 0.406,0.188 10 false SG-1 5.656,0.271 5.948,0.469 0.292,0.198 10 false 5 V 6.313,0.781 6.563,0.969 0.25,0.188 10 false IC 1.948,1.156 2.125,1.375 0.177,0.219 10 false - 1.927,0.688 2.104,0.906 0.177,0.219 10 false +

PROCEDURE

1.CONFIRM MODEL
a.

Choose the model to be inspected.


Result:
Result Proceed to
except G16E-GTS A
for G16E-GTS B



A

2.READ VALUE USING GTS

B

5.READ VALUE USING GTS
2.READ VALUE USING GTS
a.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Room Temperature Sensor Cooler (room temp. sensor) thermistor Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Actual cabin temperature displayed Cooler (room temp. sensor) thermistor circuit malfunction
Body Electrical > Air Conditioner > Data List
Tester Display
Room Temperature Sensor
50003 450 100
OK:

The display is as specified in the normal condition column.



Result:
Proceed to
OK
NG



OK

NG

3.INSPECT COOLER (ROOM TEMP. SENSOR) THERMISTOR
3.INSPECT COOLER (ROOM TEMP. SENSOR) THERMISTOR

OK

4.CHECK HARNESS AND CONNECTOR (COOLER (ROOM TEMP. SENSOR) THERMISTOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)

NG

REPLACE COOLER (ROOM TEMP. SENSOR) THERMISTOR

4.CHECK HARNESS AND CONNECTOR (COOLER (ROOM TEMP. SENSOR) THERMISTOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)

Pre-procedure1

a.

Disconnect the H25 air conditioning amplifier assembly connector.


Procedure1

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
H58-1 (+) - H25-5 (TR) Always Below 1 Ω
H58-2 (-) - H25-3 (SG-1) Always Below 1 Ω
H58-1 (+) or H25-5 (TR) - Other terminals and body ground Always 10 kΩ or higher
H58-2 (-) or H25-3 (SG-1) - Other terminals and body ground Always 10 kΩ or higher



Post-procedure1

c.

None


Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.READ VALUE USING GTS
a.

Read the Data List according to the display on the GTS.

Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Room Temperature Sensor Cooler (room temp. sensor) thermistor Min.: -327.68°C (-557.82°F)
Max.: 327.67°C (621.81°F)
Actual cabin temperature displayed Cooler (room temp. sensor) thermistor circuit malfunction
Body Electrical > Air Conditioner > Data List
Tester Display
Room Temperature Sensor
50003 450 100
OK:

The display is as specified in the normal condition column.



Result:
Proceed to
OK
NG



OK

NG

6.INSPECT COOLER (ROOM TEMP. SENSOR) THERMISTOR
6.INSPECT COOLER (ROOM TEMP. SENSOR) THERMISTOR

OK

7.CHECK HARNESS AND CONNECTOR (COOLER (ROOM TEMP. SENSOR) THERMISTOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)

NG

REPLACE COOLER (ROOM TEMP. SENSOR) THERMISTOR

7.CHECK HARNESS AND CONNECTOR (COOLER (ROOM TEMP. SENSOR) THERMISTOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)

Pre-procedure1

a.

Disconnect the H25 air conditioning amplifier assembly connector.


Procedure1

b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
H58-1 (+) - H25-5 (TR) Always Below 1 Ω
H58-2 (-) - H25-3 (SG-1) Always Below 1 Ω
H58-1 (+) or H25-5 (TR) - Other terminals and body ground Always 10 kΩ or higher
H58-2 (-) or H25-3 (SG-1) - Other terminals and body ground Always 10 kΩ or higher



Post-procedure1

c.

None


Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR