2005-2008 Yaris · Service Manual ENGINE

P0443 Evaporative Emission Control System Purge Control Valve Circuit Malfunction

Diagnostic trouble codes · Vehicles built from Aug 2005

DESCRIPTION

In order to reduce hydrocarbon (HC) emissions, evaporated fuel from the fuel tank is routed through the charcoal canister to the intake manifold for combustion in the cylinders. The ECM changes the duty signal to the EVAP VSV so that the intake of HC emissions is appropriate for the driving conditions (engine load, engine speed, vehicle speed, etc.) after the engine is warmed up.
DTC No.
DTC Detection Condition
Trouble Area
P0443
  1. Open or short in EVAP VSV circuit (3 trip detection logic)
  2. Short between EVP1 circuit and power source circuit (3 trip detection logic)
  3. Short between EVP1 and ground circuit (3 trip detection logic)
  1. Open or short in EVAP VSV circuit
  2. EVAP VSV
  3. ECM

HINT:
DTC P0443 is detected when the engine is warmed up, stops, restarts after 30 seconds, and idles for 1 minute.


WIRING DIAGRAM

A109131E01

INSPECTION PROCEDURE

NOTICE:
Perform electronic throttle learning after replacing the ECM (Click here).

HINT:
Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.


1. INSPECT EVAP VSV (RESISTANCE)
A120349E01
  1. Disconnect the EVAP VSV connector.

  1. Measure the resistance between terminals of the EVAP VSV.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 - 2
    26 to 30 Ω at 20°C (68°F)

  1. Reconnect the EVAP VSV connector.



NG
REPLACE EVAP VSV
OK


2. INSPECT TERMINAL VOLTAGE (EVAP VSV CONNECTOR)
A120349E01
  1. Disconnect the EVAP VSV connector.

  1. Turn the ignition switch on (IG).

  1. Measure the voltage between terminal 2 of the EVAP VSV connector and the body ground.

    Standard voltage:
    Tester Connection
    Specified Condition
    C3-2 - Body ground
    9 to 14 V

  1. Reconnect the EVAP VSV connector.



NG
Go to step 4
OK


3. CHECK HARNESS AND CONNECTOR (ECM - EVAP VSV)
A120350E01
  1. Disconnect the EVAP VSV connector.

  1. Disconnect the ECM connector.

  1. Check the resistance.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    EVAP VSV (C3-1) - EVP1 (C33-22)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    EVAP VSV (C3-1) or EVP1 (C33-22) - Body ground
    10 kΩ or higher

  1. Reconnect the EVAP VSV connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM

4. CHECK AND REPLACE HARNESS AND CONNECTOR (INTEGRATION RELAY - EVAP VSV)
A120351E01
  1. Remove the integration relay from the engine room relay block.

  1. Disconnect the EVAP VSV connector.

  1. Check the resistance.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    EVAP VSV (C3-2) - Engine room relay block (1A-8)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    EVAP VSV (C3-2) or Engine room relay block (1A-8) - Body ground
    10 kΩ or higher

  1. Reconnect the EVAP VSV connector.

  1. Reinstall the integration relay.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPAIR OR REPLACE POWER SOURCE CIRCUIT COMPONENTS