P0100 Mass or Volume Air Flow Circuit
Diagnostic trouble codes · Vehicles built from Nov 2006
Also covers:
- P0102 Mass or Volume Air Flow Circuit Low Input
- P0103 Mass or Volume Air Flow Circuit High Input
DESCRIPTION
The Mass Air Flow (MAF) meter is a sensor that measures the amount of air flowing through the throttle valve.The ECM uses this information to determine the fuel injection time and to provide the appropriate air-fuel ratio.
Inside the MAF meter, there is a heated platinum wire which is exposed to the flow of intake air.
By applying a specific electrical current to the wire, the ECM heats it to a given temperature. The flow of incoming air cools both the wire and an internal thermistor, affecting their resistance. To maintain a constant current value, the ECM varies the voltage applied to these components in the MAF meter. The voltage level is proportional to the airflow through the sensor, and the ECM uses it to calculate the intake air volume.
The circuit is constructed so that the platinum hot wire and the temperature sensor create a bridge circuit, and the power transistor is controlled so that the potentials of A and B remain equal to maintain the predetermined temperature.
- HINT:
- When any of these DTCs are set, the ECM enters fail-safe mode. During fail-safe mode, the ignition timing is calculated by the ECM, according to the engine RPM and throttle valve position. Fail-safe mode continues until a pass condition is detected.


| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0100 |
Mass air flow meter voltage less than 0.2 V, or more than 4.9 V for 3 seconds or more when engine speed less than 4000 rpm (1 trip detection logic) |
|
| P0102 |
Mass air flow meter voltage less than 0.2 V for 3 seconds or more when engine speed less than 4000 rpm (1 trip detection logic) |
|
| P0103 |
Mass air flow meter voltage more than 4.9 V for 3 seconds or more when engine speed less than 4000 rpm (1 trip detection logic) |
|
- HINT:
- When any of these DTCs are set, check the air-flow rate by selecting the following menu items on an intelligent tester: Powertrain / Engine and ECT / Data List / MAF.
Mass Air Flow Rate (g/sec)
Malfunction
Approximately 0.0
- Open in mass air flow meter power source circuit
- Open or short in VG circuit
271.0 or more
- Open in E2G circuit
- Open in mass air flow meter power source circuit
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- Read freeze frame data using an intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
| 1. READ VALUE USING INTELLIGENT TESTER (MASS AIR FLOW RATE) |
Connect an intelligent tester to the DLC3.
Start the engine.
Turn the tester on.
Select the following menu items: Powertrain / Engine and ECT / Data List / MAF.
Read the value.
- Result:
Mass Air Flow Rate (g/sec)
Proceed to
0.0
A
271.0 or more
B
Between 1.0 and 270.0 (*1)
C
|
|
||||
|
|
||||
| A | |
| 2. INSPECT MASS AIR FLOW METER (POWER SOURCE VOLTAGE) |
Disconnect the mass air flow meter connector.

Turn the ignition switch on (IG).
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Switch Condition
Specified Condition
C68-3 (+B) - Body ground
Ignition switch on (IG)
11 to 14 V
Reconnect the mass air flow meter connector.
|
|
||||
| OK | |
| 3. INSPECT MASS AIR FLOW METER (VG VOLTAGE) |
Inspect output voltage.

Disconnect the mass air flow meter connector.
Apply battery voltage across terminals +B and E2G.
Connect the positive (+) tester probe to terminal VG, and the negative (-) tester probe to terminal E2G.
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
5 (VG) - 4 (E2G)
Apply battery voltage across terminal +B and E2G
0.2 to 4.9 V
Reconnect the mass air flow meter connector.
|
|
||||
| OK | |
| 4. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
Disconnect the mass air flow meter connector.

Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance (Check for open):
Tester Connection
Condition
Specified Condition
C68-5 (VG) - C20-118 (VG)
Always
Below 1 Ω
C68-4 (E2G) - C20-116 (E2G)
Always
Below 1 Ω
- Standard resistance (Check for short):
Tester Connection
Condition
Specified Condition
C68-5 (VG) or C20-118 (VG) - Body ground
Always
10 kΩ or higher
Reconnect the mass air flow meter connector.
Reconnect the ECM connector.
|
|
||||
| OK | ||
| ||
| 5. INSPECT FUSE (EFI2) |
Remove the EFI2 fuse from engine room R/B and J/B.

Measure the EFI2 fuse resistance.
- Standard resistance:
- Below 1 Ω
Reinstall the EFI2 fuse.
|
|
||||
| OK | |
| 6. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - INTEGRATION RELAY) |
Disconnect the mass air flow meter connector.

Remove the integration relay (EFI relay) from the engine room R/B and J/B.
Measure the resistance according to the value(s) in the table below.
- Standard resistance (Check for open):
Tester Connection
Condition
Specified Condition
C68-3 (+B) - 1A-4
Always
Below 1 Ω
- Standard resistance (Check for short):
Tester Connection
Condition
Specified Condition
C68-3 (+B) or 1A-4 - Body ground
Always
10 kΩ or higher
Reconnect the mass air flow meter connector.
Reinstall the integration relay.
|
|
||||
| OK | ||
| ||
| 7. CHECK HARNESS AND CONNECTOR (SENSOR GROUND) |
Disconnect the mass air flow meter connector.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
C68-4 (E2G) - Body ground
Always
Below 1 Ω
Reconnect the mass air flow meter connector.
- Result:
Result
Proceed to
Outside standard range
A
Within standard range
B
|
|
||||
| A | |
| 8. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
Disconnect the mass air flow meter connector.

Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance (Check for open):
Tester Connection
Condition
Specified Condition
C68-5 (VG) - C20-118 (VG)
Always
Below 1 Ω
C68-4 (E2G) - C20-116 (E2G)
Always
Below 1 Ω
- Standard resistance (Check for short):
Tester Connection
Condition
Specified Condition
C68-5 (VG) or C20-118 (VG) - Body ground
Always
10 kΩ or higher
Reconnect the mass air flow meter connector.
Reconnect the ECM connector.
|
|
||||
| OK | ||
| ||