Fuel Injector Circuit
Circuit diagnosis · Vehicles built from Nov 2006
DESCRIPTION
The fuel injectors are located on the intake manifold. They inject fuel into the cylinders based on the signals from the ECM.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT POWER SOURCE CIRCUIT |
Disconnect the fuel injector connector.

Turn the ignition switch on (IG).
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Switch Condition
Specified Condition
C4-1 - Body ground
Ignition switch on (IG)
11 to 14 V
C5-1 - Body ground
Ignition switch on (IG)
11 to 14 V
C6-1 - Body ground
Ignition switch on (IG)
11 to 14 V
C7-1 - Body ground
Ignition switch on (IG)
11 to 14 V
Reconnect the fuel injector connector.
|
|
||||
| OK | |
| 2. INSPECT FUEL INJECTOR (INJECTION AND VOLUME) |
Check the fuel injector injection and volume (Click here).
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (FUEL INJECTOR - ECM) |
Disconnect the ECM connector.

Disconnect the fuel injector connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance (Check for open):
Tester Connection
Condition
Specified Condition
C4-2 - C20-108 (#10)
Always
Below 1 Ω
C5-2 - C20-107 (#20)
Always
Below 1 Ω
C6-2 - C20-106 (#30)
Always
Below 1 Ω
C7-2 - C20-105 (#40)
Always
Below 1 Ω
- Standard resistance (Check for short):
Tester Connection
Condition
Specified Condition
C4-2 or C20-108 (#10) - Body ground
Always
10 kΩ or higher
C5-2 or C20-107 (#20) - Body ground
Always
10 kΩ or higher
C6-2 or C20-106 (#30) - Body ground
Always
10 kΩ or higher
C7-2 or C20-105 (#40) - Body ground
Always
10 kΩ or higher
Reconnect the fuel injector connector.
Reconnect the ECM connector.
|
|
||||
| OK | ||
| ||
| 4. INSPECT FUSE (AM2 FUSE) |
Remove the AM2 fuse.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
AM2 fuse
Always
Below 1 Ω
Reinstall the AM2 fuse.
|
|
||||
| OK | |
| 5. INSPECT INTEGRATION RELAY (IG2 RELAY) |
Remove the integration relay (IG2 relay) from the engine room R/B and J/B.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
1C-1 - 1B-4
Always
10 kΩ or higher
1C-1 - 1B-4
Battery voltage applied to terminals 1B-2 and 1B-3
Below 1 Ω
Reinstall the integration relay.
|
|
||||
| OK | ||
| ||