2005-2008 Yaris · Service Manual ENGINE

P1600 ECM BATT Malfunction

Diagnostic trouble codes · Vehicles built from Nov 2005

DESCRIPTION

Refer to DTC P0685 (Click here).
DTC No.
DTC Detection Conditions
Trouble Areas
P1600
Battery voltage is 4 V or less, or 17 V or more
(The MIL is illuminated and a DTC is immediately set when a malfunction is detected)
  1. Open or short in +B terminal circuit
  2. Tired battery
  3. Electrical overwork
  4. Generator
  5. Battery (If 24 V battery is fitted, DTC P1600 is output)
  6. ECM

HINT:
DTC P1600 is set when the engine idles for 60 seconds or more.


WIRING DIAGRAM

Refer to DTC P0685 (Click here).

INSPECTION PROCEDURE


1. INSPECT BATTERY
  1. Check that the battery is not depleted (Click here).

    OK:
    Battery is not depleted.



NG
REPLACE BATTERY
OK


2. INSPECT INTEGRATION RELAY (ECD FUSE AND ECD RELAY)

  1. A107921E24
    Remove the integration relay from the engine room relay block.

  1. Inspect the ECD fuse.

    1. Remove the ECD fuse from the integration relay.

    2. Check the ECD fuse resistance.

      Standard resistance:
      Below 1 Ω

    3. Reinstall the ECD fuse.

  1. Inspect the ECD relay.

    1. Check the ECD relay resistance.

      Standard resistance:
      Tester Connections
      Specified Conditions
      1C-1 - 1A-8
      10 kΩ or higher
      Below 1 Ω
      (Apply battery voltage between terminals 1C-1 and 1A-7)

  1. Reinstall the integration relay.



NG
REPLACE INTEGRATION RELAY AND/OR FUSE
OK


3. CHECK HARNESS AND CONNECTOR (ECD RELAY - ECM, ECD FUSE - BATTERY)

  1. A122671E01
    Check the harness connectors between the ECD relay and ECM.
    1. Remove the integration relay from the engine room relay block.

    2. Disconnect the A49 ECM connector.

    3. Check the resistance.

      Standard resistance (Check for open):
      Tester Connections
      Specified Conditions
      Integration relay (1A-7) - MREL (A49-44)
      Below 1 Ω
      Integration relay (1A-8) - +B (A49-42)
      Integration relay (1A-8) - +B1 (A49-1)

      Standard resistance (Check for short):
      Tester Connections
      Specified Conditions
      Integration relay (1A-7) or MREL (A49-44) - Body ground
      10 kΩ or higher
      Integration relay (1A-8) or +B (A49-42) - Body ground
      Integration relay (1A-8) or +B1 (A49-1) - Body ground

    4. Reinstall the integration relay.

    5. Reconnect the ECM connector.

  1. Check the harness and connector between the ECD fuse and battery.

    1. Remove the integration relay from the engine room relay block.

    2. Disconnect the positive battery cable.

    3. Check the resistance.

      Standard resistance (Check for open):
      Tester Connections
      Specified Conditions
      Positive battery cable terminal - Integration relay (1C-1)
      Below 1 Ω

      Standard resistance (Check for short):
      Tester Connections
      Specified Conditions
      Positive battery cable terminal or Integration relay (1C-1) - Body ground
      10 kΩ or higher

    4. Reinstall the integration relay.

    5. Reconnect the battery cable.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4. INSPECT GENERATOR ASSEMBLY
  1. Check the generator assembly (Click here).

HINT:
  1. If +B voltage drop is caused by generator malfunctions, the charge light illuminates.
  2. If the voltage at the terminal of the generator is more than 17 V, the generator malfunctions.



NG
REPAIR OR REPLACE GENERATOR ASSEMBLY
OK

REPLACE ECM


← P1520 Stop Light Switch Circuit Malfunction (from Nov 2005)P2227 Barometric Pressure Circuit Range / Performance (from Nov 2005) →