Home › Vehicle Exterior › LIGHTING (EXT) › LIGHTING SYSTEM

LIGHTING SYSTEM > Hazard Warning Switch Circuit

for Preparation Click here


DESCRIPTION

The combination meter assembly receives information signals from the hazard warning signal switch assembly.

WIRING DIAGRAM


E231512E01


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.READ VALUE USING INTELLIGENT TESTER
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the intelligent tester on.

  1. Enter the following menus: Body / Combination Meter / Data List.

  1. According to the display on the intelligent tester, read the Data List.

    Combination Meter 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Hazard Flasher Switch
    Hazard warning signal switch /
    OFF or ON
    OFF: Hazard warning signal switch off
    ON: Hazard warning signal switch on
    -

    OK:
    Normal conditions listed above are displayed.



NG
Go to step 2
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY
  1. Inspect the hazard warning signal switch assembly (Click here).



NG
REPLACE HAZARD WARNING SIGNAL SWITCH ASSEMBLY (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY)
E219681E01
  1. Disconnect the F3 combination meter assembly connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    F3-1 (B) - Body Ground
    Always
    11 to 14 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Combination Meter Assembly)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK HARNESS AND CONNECTOR (HAZARD WARNING SIGNAL SWITCH ASSEMBLY - COMBINATION METER ASSEMBLY)
  1. Disconnect the F2 hazard warning signal switch assembly connector.

  1. Disconnect the F3 combination meter assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    F2-4 - F3-3 (HAZ)
    Always
    Below 1 Ω
    F2-1 - Body Ground
    Always
    Below 1 Ω
    F2-4 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)