Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)

AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) > Blower Motor Circuit

for Preparation Click here


DESCRIPTION

The blower motor with fan sub-assembly operates according to signals from the air conditioning amplifier assembly. The blower motor with fan sub-assembly speed signals are transmitted by changes in the duty ratio.

WIRING DIAGRAM


E231124E01


E231125E01


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the intelligent tester on.

  1. Enter the following menus: Body / Air Conditioner / Active Test.

  1. According to the display on the intelligent tester, perform the Active Test.

    Air Conditioner 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Blower Motor
    Blower motor
    Min.: 0, Max.: 31
    -

    OK:
    Blower motor with fan sub-assembly operates and blower motor speed changes.


    Result 
    Result
    Proceed to
    OK
    A
    NG (Blower motor with fan sub-assembly does not operate)*1
    B
    NG (Blower motor with fan sub-assembly operates but blower motor speed does not change)*1
    C
    NG (Blower motor with fan sub-assembly operates or blower motor speed changes)*2
    D
    1. *1: for LHD
    2. *2: for RHD



B
Go to step 2

C
Go to step 7

D
Go to step 9
A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.INSPECT BLOWER MOTOR WITH FAN SUB-ASSEMBLY
  1. Inspect the blower motor with fan sub-assembly (Click here).



NG
REPLACE BLOWER MOTOR CONTROL (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (NO. 1 AIR CONDITIONING WIRE - BATTERY AND BODY GROUND)


    E229331E01
  1. Disconnect the C No. 1 air conditioning wire connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    C-1 - Body ground
    Always
    11 to 14 V

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    C-6 - Body ground
    Always
    Below 1 Ω

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to No. 1 Air Conditioning Wire)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - NO. 1 AIR CONDITIONING WIRE BODY GROUND)
  1. Disconnect the F42 air conditioning amplifier assembly connector.

  1. Disconnect the C No. 1 air conditioning wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    F42-22 (BLW) - C-3
    Always
    Below 1 Ω
    F42-14 (GND) - Body ground
    Always
    Below 1 Ω
    F42-22 (BLW) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN SUB-ASSEMBLY - NO. 1 AIR CONDITIONING WIRE AND BODY GROUND)
  1. Disconnect the F96 blower motor with fan sub-assembly connector.

  1. Disconnect the C No. 1 air conditioning wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    F96-2 - C-2
    Always
    Below 1 Ω
    F96-1 - Body ground
    Always
    Below 1 Ω
    F96-2 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.INSPECT NO. 1 AIR CONDITIONING WIRE
  1. Remove the No. 1 air conditioning wire.



    E229332E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    C-1 - F97-1 (+B)
    Always
    Below 1 Ω
    C-2 - F97-2 (VM)
    Always
    Below 1 Ω
    C-3 - F97-3 (SI)
    Always
    Below 1 Ω
    C-6 - F97-6 (GND)
    Always
    Below 1 Ω
    C-1 - Body ground
    Always
    10 kΩ or higher
    C-2 - Body ground
    Always
    10 kΩ or higher
    C-3 - Body ground
    Always
    10 kΩ or higher
    C-6 - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *1
    No. 1 Air Conditioning Wire



NG
REPLACE NO. 1 AIR CONDITIONING WIRE
OK


7.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY


    E219641E01
  1. Remove the air conditioning amplifier assembly (Click here).

  1. Remove the No. 1 air conditioning wire.

  1. Reconnect the air conditioning amplifier assembly connector.

  1. Reconnect the blower motor with fan sub-assembly connector.

  1. Using an oscilloscope, check the waveform.
    Measurement Condition 
    Item
    Content
    Terminal No. (Symbol)
    F42-22 (BLW) - F42-14 (GND)
    Tester Range
    1 V/DIV., 500 μs/DIV.
    Condition
    Ignition switch ON
    Blower switch LO

    OK:
    Waveform is as shown in the illustration.

    HINT:
    Waveform varies with the blower level.

    Text in Illustration 
    *a
    Component with harness connected
    (Air Conditioning Amplifier Assembly)



NG
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
OK


8.REPLACE BLOWER MOTOR CONTROL
  1. Replace the blower motor control with a new or normally functioning one (Click here).

  1. Operate the blower motor with fan sub-assembly to check that it functions properly.

    OK:
    Blower motor with fan sub-assembly operates normally.



NG
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
OK

END (BLOWER MOTOR CONTROL IS FAULTY) 

9.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN SUB-ASSEMBLY - BATTERY AND BODY GROUND)


    E219640E01
  1. Disconnect the F36 blower motor with fan sub-assembly connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    F36-3 (+B) - Body ground
    Always
    11 to 14 V

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    F36-1 (GND) - Body ground
    Always
    Below 1 Ω

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Blower Motor with Fan Sub-Assembly)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


10.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BLOWER MOTOR WITH FAN SUB-ASSEMBLY AND BODY GROUND)
  1. Disconnect the F42 air conditioning amplifier assembly connector.

  1. Disconnect the F36 blower motor with fan sub-assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    F42-22 (BLW) - F36-2 (SI)
    Always
    Below 1 Ω
    F42-14 (GND) - Body ground
    Always
    Below 1 Ω
    F42-22 (BLW) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


11.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (BLW SIGNAL)


    E219641E01
  1. Remove the air conditioning amplifier assembly (Click here).

  1. Reconnect the air conditioning amplifier assembly connector.

  1. Reconnect the blower motor with fan sub-assembly connector.

  1. Using an oscilloscope, check the waveform.
    Measurement Condition 
    Item
    Content
    Terminal No. (Symbol)
    F42-22 (BLW) - F42-14 (GND)
    Tester Range
    1 V/DIV., 500 μs/DIV.
    Condition
    Ignition switch ON
    Blower switch LO

    OK:
    Waveform is as shown in the illustration.

    HINT:
    Waveform varies with the blower level.

    Text in Illustration 
    *a
    Component with harness connected
    (Air Conditioning Amplifier Assembly)



NG
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
OK


12.REPLACE BLOWER MOTOR WITH FAN SUB-ASSEMBLY
  1. Replace the blower motor with fan sub-assembly with a new or normally functioning one (Click here).

  1. Operate the blower motor with fan sub-assembly to check that it functions properly.

    OK:
    Blower motor with fan sub-assembly operates normally.



NG
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
OK

END (BLOWER MOTOR WITH FAN SUB-ASSEMBLY IS FAULTY)