Suzuki Vitara (LY) 2016-2017 · Service Manual M16A · Diagnostic Information and Procedures

Generator Symptom Diagnosis

Precautions: Precautions for Handling Battery · Precautions for Replacing Battery · General safety (00)

Trouble in charging system will show up as one or more of the following conditions.
Charging Warning Light Operation
NOTE:
When ENG A-STOP system stops engine in normal condition, charge warning light does not light up.
Check “Charge Light” in Scan Tool Data to identify easily most possible cause of trouble. “Charge Light” indicates command signal of charge warning light from ECM to combination meter.
Condition Possible Cause Action
Charge warning light does not light with ignition “ON” and engine off
Blown fuse
Replace fuse.
Faulty combination meter
Replace combination meter. icon 
Faulty ECM
Check ECM. icon 
Faulty CAN communication line
Repair or replace CAN communication line. icon 
Faulty wiring
Repair or replace wiring.
Faulty IC regulator or field coil
Repair or replace generator. icon 
Charge warning light does not go out with engine running (battery requires frequent recharging)
Loose or worn drive belt
Adjust or replace drive belt. icon 
Faulty combination meter
Replace combination meter. icon 
Faulty ECM
Check ECM. icon 
Faulty IC regulator or generator
Repair or replace generator. icon 
Faulty wiring
Repair or replace wiring.

Battery Charge Failure
Condition Possible Cause Action
Undercharged battery
Loose or worn drive belt
Adjust or replace drive belt. icon 
Loose or corroded battery terminal
Tighten battery terminal or replace battery. icon 
Faulty rectifier, rotor and/or IC regulator
Repair or replace generator. icon 
Overcharged battery
Faulty IC regulator
Repair or replace generator. icon 

Noise
Condition Possible Cause Action
Noisy generator
Loose mounting bolts
Tighten mounting bolts. icon 
Dirty, worn and/or faulty bearings
Repair or replace generator. icon 
Faulty rotor, diode and/or stator