A/C System Symptom Diagnosis
Precautions: General safety (00)
| Condition | Possible Cause | Action |
|---|---|---|
|
Blower motor does not operate
|
Blown fuse
|
Check related fuses, and then check for short circuit to ground.
|
|
Faulty blower motor relay
|
||
|
Faulty blower motor resistor
|
||
|
Faulty blower speed selector
|
||
|
Faulty blower motor
|
||
|
Foreign material is present
|
Remove foreign material.
|
|
|
Faulty wiring or grounding
|
Repair wiring.
|
|
|
Air outlet ports do not change or do not agree with air flow selector’s position even if air flow selector is changed
|
Broken or bent air flow control cable
|
Check air flow control cable.
|
|
Faulty air flow selector
|
Check air flow selector.
|
|
|
Incorrect installation of air flow control cable
|
Check position of cable and adjust it if necessary.
|
|
|
Leaky or clogged air ducts
|
Repair air ducts.
|
|
|
Broken air flow control door assembly
|
Repair air flow control door assembly.
|
|
|
Air intake door does not change even if air intake mode is changed
|
Blown fuse
|
Check related fuses, and then check for short circuit to ground.
|
|
Faulty air intake control actuator
|
||
|
Faulty air intake switch
|
||
|
Broken air intake door
|
Repair air intake door.
|
|
|
Faulty wiring or grounding
|
Repair wiring.
|
|
|
Warm air does not come out or insufficient heating (Faulty temperature control)
|
Broken or bent temperature control cable
|
Check temperature control cable.
|
|
Faulty temperature selector
|
Check temperature selector.
|
|
|
Incorrect installation of temperature control cable
|
Check position of cable and adjust it if necessary.
|
|
|
Clogged air ducts
|
Repair air ducts.
|
|
|
Faulty additional heater system (if equipped)
|
||
|
Faulty thermostat (Petrol model)
|
||
|
Faulty ECT sensor
|
Check ECT sensor.
|
|
|
Leaky or clogged heater hoses
|
Replace heater hoses.
|
|
|
Broken temperature control door assembly
|
Repair temperature control door assembly.
|
|
|
Leaky or clogged heater core
|
Replace heater core.
|
|
|
No cool air comes out (A/C compressor does not operate)
|
Blown fuse
|
Check related fuses, and then check for short circuit to ground.
|
|
Faulty A/C compressor relay
|
||
|
Faulty A/C switch
|
||
|
Faulty blower speed selector
|
||
|
Faulty BCM
|
||
|
Faulty ESP®
|
||
|
Faulty ECM and its circuit
|
||
|
Faulty magnet clutch (petrol model)
|
||
|
Faulty compressor pulley (diesel model)
|
||
|
Faulty compressor ON/OFF valve (diesel model)
|
||
|
Loose or broken compressor drive belt (petrol model)
|
||
|
Loose or broken generator drive belt (diesel model)
|
||
|
Faulty compressor
|
Check compressor.
|
|
|
Faulty ECT sensor
|
Check ECT sensor.
|
|
|
No refrigerant
|
Check amount of refrigerant and system for leakage.
|
|
|
Faulty A/C refrigerant pressure sensor
|
||
|
Faulty evaporator temperature sensor
|
||
|
Faulty HVAC control module
|
||
|
Faulty wiring or grounding
|
Repair wiring.
|
|
|
No cool air comes out (radiator cooling fan motor does not operate)
|
Blown fuse
|
Check related fuses, and then check for short circuit to ground.
|
|
Faulty radiator cooling fan relay
|
||
|
Faulty radiator cooling fan motor
|
Check radiator cooling fan motor.
|
|
|
Faulty ECM and its circuit
|
||
|
Faulty wiring or grounding
|
Repair wiring.
|
|
|
Cool air does not come out or insufficient cooling (A/C compressor in normal operation)
|
Faulty blower motor
|
|
|
Air leakage from HVAC unit or air duct
|
Repair HVAC unit or air duct.
|
|
|
Loose or broken compressor drive belt (petrol model)
|
||
|
Loose or broken generator drive belt (diesel model)
|
||
|
Faulty magnet clutch (petrol model)
|
||
|
Faulty compressor pulley (diesel model)
|
||
|
Faulty compressor ON/OFF valve (diesel model)
|
||
|
Faulty compressor
|
Check compressor.
|
|
|
Faulty expansion valve
|
||
|
Clogged desiccant
|
Check desiccant and cap.
|
|
|
Faulty heater and ventilation system
|
Check HVAC unit.
|
|
|
Insufficient or excessive charge of refrigerant
|
Check amount of refrigerant and system for leakage.
|
|
|
Excessive compressor oil in A/C system
|
Drain excessive compressor oil from A/C system circuit and compressor.
|
|
|
Clogged condenser
|
||
|
Clogged or frosted evaporator
|
Check evaporator and evaporator temperature sensor.
|
|
|
Faulty evaporator temperature sensor
|
||
|
Air in A/C system
|
||
|
Cool air does not come out intermittently
|
Faulty magnet clutch (petrol model)
|
|
|
Faulty compressor pulley (diesel model)
|
||
|
Faulty compressor ON/OFF valve (diesel model)
|
||
|
Excessive amount of refrigerant
|
Check the amount of refrigerant.
|
|
|
Faulty expansion valve
|
||
|
Faulty evaporator temperature sensor
|
||
|
Excessive moisture in A/C system
|
||
|
Faulty wiring connection
|
Repair wiring.
|
|
|
Cool air comes out only at high speed
|
Loose compressor drive belt (petrol model)
|
|
|
Loose or broken generator drive belt (diesel model)
|
||
|
Faulty compressor
|
Check compressor.
|
|
|
Clogged condenser
|
||
|
Insufficient charge of refrigerant
|
Check amount of refrigerant and system for leakage.
|
|
|
Air in A/C system
|
||
|
Cool air does not come out only at high speed
|
Excessive amount of refrigerant
|
Check amount of refrigerant.
|
|
Frosted evaporator
|
Check evaporator and evaporator temperature sensor.
|
|
|
Insufficient cool air flow
|
Faulty blower motor
|
|
|
Air leakage from HVAC unit or air duct
|
Repair HVAC unit or air duct.
|
|
|
Clogged or frosted evaporator
|
Check evaporator and evaporator temperature sensor.
|
|
|
Faulty wiring or grounding
|
Repair wiring.
|
|
|
Heating performance is poor (for additional heater system)
|
Blown fuse
|
Check related fuses and check for short circuit to ground.
|
|
Faulty additional heater relays
|
||
|
Faulty max hot switch
|
||
|
Faulty additional heater
|
||
|
Faulty ECM and its circuit
|
||
|
Faulty wiring or grounding
|
Repair wiring.
|