Refer to DTC P2237 (See page Engine / Hybrid System>1GR-FE ENGINE CONTROL>SFI SYSTEM>P2237).
Although the DTC titles say heated oxygen sensor, these DTCs relate to the air fuel ratio sensor.
Sensor 1 refers to the sensor mounted in front of the Three-Way Catalytic Converter (TWC) and located near the engine assembly.
When one of these DTCs is stored, the ECM enters fail-safe mode. The ECM turns off the air fuel ratio sensor heater in fail-safe mode. The ECM continues operating in fail-safe mode until the ignition switch is turned off.
The ECM provides a pulse width modulated control circuit to adjust the current through the heater. The air fuel ratio sensor heater circuit uses a relay on the +B side of the circuit.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0031
P0051 |
Air fuel ratio sensor heater current is below 0.8 A (1 trip detection logic). | ·
Open in air fuel ratio sensor heater circuit ·
Air fuel ratio sensor heater (sensor 1) ·
No. 1 integration relay ·
ECM |
| P0032
P0052 |
Air fuel ratio sensor heater current failure (1 trip detection logic). | ·
Short in air fuel ratio sensor heater circuit ·
Air fuel ratio sensor heater (sensor 1) ·
No. 1 integration relay ·
ECM |
| P101D
P103D |
The heater current is higher than the specified value while the heater is not operating (1 trip detection logic). | ECM |
Bank 1 refers to the bank that includes cylinder No. 1.
Bank 2 refers to the bank that does not include cylinder No. 1.
Sensor 1 refers to the sensor closest to the engine assembly.
Sensor 2 refers to the sensor farthest away from the engine assembly.
The ECM uses information from the air fuel ratio sensor to regulate the air-fuel ratio and keep it close to the stoichiometric level. This maximizes the ability of the Three-Way Catalytic Converter (TWC) to purify the exhaust gases.
The air fuel ratio sensor detects oxygen levels in the exhaust gas and transmits the information to the ECM. The inner surface of the sensor element is exposed to the outside air. The outer surface of the sensor element is exposed to the exhaust gas. The sensor element is made of platinum coated zirconia and includes an integrated heating element.
The zirconia element generates a small voltage when there is a large difference in the oxygen concentrations between the exhaust gas and outside air. The platinum coating amplifies this voltage generation.
The air fuel ratio sensor is more efficient when heated. When the exhaust gas temperature is low, the sensor cannot generate useful voltage signals without supplementary heating. The ECM regulates the supplementary heating using a duty-cycle approach to adjust the average current in the sensor heater element. If the heater current is outside the normal range, the signal transmitted by the air fuel ratio sensor becomes inaccurate. As a result, the ECM is unable to regulate the air-fuel ratio properly.
When the current in the air fuel ratio sensor heater is outside the normal operating range, the ECM interprets this as a malfunction in the sensor heater and stores a DTC.
Refer to DTC P2237 (See page Engine / Hybrid System>1GR-FE ENGINE CONTROL>SFI SYSTEM>P2237).
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Inspect the air fuel ratio sensor (See page Engine / Hybrid System>1GR-FE ENGINE CONTROL>AIR FUEL RATIO SENSOR>INSPECTION).
OK
NG
Disconnect the air fuel ratio sensor connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B26-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| B27-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| *A | Bank 1 |
| *B | Bank 2 |
| *a | Front view of wire harness connector
(to Air Fuel Ratio Sensor) |
Reconnect the air fuel ratio sensor connector.
OK
NG
Disconnect the air fuel ratio sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B26-1 (HA1A) - B39-17 (HA1A) | Always | Below 1 Ω |
| B27-1 (HA2A) - B39-19 (HA2A) | Always | Below 1 Ω |
| B26-1 (HA1A) or B39-17 (HA1A) - Body ground | Always | 10 kΩ or higher |
| B27-1 (HA2A) or B39-19 (HA2A) - Body ground | Always | 10 kΩ or higher |
Reconnect the air fuel ratio sensor connector.
Reconnect the ECM connector.
OK
NG
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Clear DTCs (See page Engine / Hybrid System>1GR-FE ENGINE CONTROL>SFI SYSTEM>DTC CHECK / CLEAR).
Start the engine.
Allow the engine to idle for 1 minute or more.
Read the output pending DTCs using the intelligent tester.
| Display (DTC Output) | Proceed to |
|---|---|
| No pending DTC is output | A |
| Pending DTC P0031, P0032, P0051, P0052, P101D or P103D is output | B |
A
B
Inspect the No. 1 integration relay (A/F) (See page Engine / Hybrid System>1GR-FE ENGINE CONTROL>RELAY>ON-VEHICLE INSPECTION).
OK
NG
Disconnect the air fuel ratio sensor connector.
Remove the No. 1 integration relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B26-2 (+B) - 1D-8 | Always | Below 1 Ω |
| B27-2 (+B) - 1D-8 | Always | Below 1 Ω |
| 1D-7 - Body ground | Always | Below 1 Ω |
| B26-2 (+B) or 1D-8 - Body ground | Always | 10 kΩ or higher |
| B27-2 (+B) or 1D-8 - Body ground | Always | 10 kΩ or higher |
Reconnect the air fuel ratio sensor connector.
Reinstall the No. 1 integration relay.
OK
NG