In order to obtain a high purification rate of the carbon monoxide (CO), hydrocarbon (HC) and nitrogen oxide (NOx) components in the exhaust gas, a three-way catalytic converter is used. For the most efficient use of the three-way catalytic converter, the air-fuel ratio must be precisely controlled so that it is always close to the stoichiometric air-fuel level. For the purpose of helping the ECM to deliver accurate air-fuel ratio control, a heated oxygen sensor is used.
The heated oxygen sensor is located between the front and rear catalysts, and detects the oxygen concentration in the exhaust gas. Since the sensor is integrated with a heater that heats the sensing portion, it is possible to detect the oxygen concentration even when the intake air volume is low (the exhaust gas temperature is low).
When the air-fuel ratio becomes lean, the oxygen concentration in the exhaust gas is rich. The heated oxygen sensor informs the ECM that the post-three-way catalytic converter air-fuel ratio is lean (low voltage, i.e. below 0.45 V).
Conversely, when the air-fuel ratio is richer than the stoichiometric air-fuel level, the oxygen concentration in the exhaust gas becomes lean. The heated oxygen sensor informs the ECM that the post-three-way catalytic converter air-fuel ratio is rich (high voltage, i.e. higher than 0.45 V). The heated oxygen sensor has the property of changing its output voltage drastically when the air-fuel ratio is close to the stoichiometric level.
The ECM uses the supplementary information from the heated oxygen sensor to determine whether the air-fuel ratio after the three-way catalytic converter is rich or lean and adjusts the fuel injection time accordingly. Thus, if the heated oxygen sensor is working improperly due to internal malfunctions, the ECM is unable to compensate for deviations in primary air-fuel ratio control.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0137
P0157 |
·
Low voltage (open): During active air-fuel ratio control, conditions (a) and (b) are met for a certain period of time (2 trip detection logic): (a) Heated oxygen sensor voltage output is below 0.21 V. (b) Target air-fuel ratio is rich. |
·
Open in heated oxygen sensor (for Bank 1, 2) circuit ·
Heated oxygen sensor (bank 1, 2 sensor 2) ·
Heated oxygen sensor heater (bank 1, 2 sensor 2) ·
Air fuel ratio sensor (bank 1, 2 sensor 1) ·
No. 1 integration relay ·
Gas leak from exhaust system |
The ECM usually performs air-fuel ratio feedback control so that the air fuel ratio sensor output indicates a near stoichiometric air-fuel level. This vehicle includes active air-fuel ratio control in addition to regular air-fuel ratio control. The ECM performs active air-fuel ratio control to detect any deterioration in the three-way catalytic converter and heated oxygen sensor malfunctions (refer to the diagram below).
Active air-fuel ratio control is performed for approximately 15 to 20 seconds while driving with a warm engine. During active air-fuel ratio control, the air-fuel ratio is forcibly regulated to become lean or rich by the ECM. If the ECM detects a malfunction, a DTC is stored.
During active air-fuel ratio control, the ECM calculates the Oxygen Storage Capacity (OSC)* of the three-way catalytic converter by forcibly regulating the air-fuel ratio to become rich or lean. If the heated oxygen sensor has an open or short, or the voltage output of the sensor decreases significantly, the OSC indicates an extraordinarily high value. Even if the ECM attempts to continue regulating the air-fuel ratio so that it becomes rich or lean, the heated oxygen sensor output does not change.
While performing active air-fuel ratio control, when the target air-fuel ratio is rich and the heated oxygen sensor voltage output is 0.21 V or less (lean), the ECM interprets this as an abnormally low sensor output voltage and stores DTC P0137 or P0157.
*: The TWC has the capability to store oxygen. The OSC and the emission purification capacity of the three-way catalytic converter are mutually related. The ECM determines whether the catalyst has deteriorated based on the calculated OSC value.
In order to detect any deterioration in the three-way catalytic converter, the ECM calculates the Oxygen Storage Capacity (OSC) of the three-way catalytic converter. This calculation is based on the voltage output of the heated oxygen sensor while performing active air fuel ratio control.
The OSC value is an indication of the oxygen storage capacity of the three-way catalytic converter. When the vehicle is being driven with a warm engine, active air fuel ratio control is performed for approximately 15 to 20 seconds.
When it is performed, the ECM deliberately sets the air fuel ratio to lean or rich levels. If the rich-lean cycle of the heated oxygen sensor is long, the OSC becomes greater. There is a direct correlation between the OSCs of the heated oxygen sensor and the three-way catalytic converter.
This confirmation driving pattern is used in the "Perform Confirmation Driving Pattern" procedure of the following diagnostic troubleshooting procedure.
Performing this confirmation pattern will activate the heated oxygen sensor monitor (the catalyst monitor is performed simultaneously). This is very useful for verifying the completion of a repair.
This test will not be completed if the vehicle is driven under absolutely constant speed conditions, such as with cruise control activated.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the intelligent tester on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC operation).
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON and turn the intelligent tester on [A].
Start the engine and warm it up until the ECT reaches 75°C (167°F) or higher [B].
With the transmission in 4th gear or higher, drive the vehicle at a speed between 60 and 120 km/h (40 and 75 mph) for 10 minutes or more [C].
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes [D].
Read the pending DTCs.
If a pending DTC is output, the system is malfunctioning.
If a pending DTC is not output, perform the following procedure.
Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
Input the DTC: P0137 and P0157.
Check the DTC judgment result.
| Tester Display | Description |
|---|---|
| NORMAL | ·
DTC judgment completed ·
System normal |
| ABNORMAL | ·
DTC judgment completed ·
System abnormal |
| INCOMPLETE | ·
DTC judgment not completed ·
Perform driving pattern after confirming DTC enabling conditions |
| UNKNOWN | ·
Unable to perform DTC judgment ·
Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit |
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
If the judgment result shows INCOMPLETE or UNKNOWN, perform steps [C] and [D].
Malfunctioning areas can be identified by performing the Control the Injection Volume for A/F sensor function provided in the Active Test. The Control the Injection Volume for A/F sensor function can help to determine whether the air fuel ratio sensor, heated oxygen sensor and other potential trouble areas are malfunctioning.
The following instructions describe how to conduct the Control the Injection Volume for A/F sensor operation using the intelligent tester.
Connect the intelligent tester to the DLC3.
Start the engine and turn the intelligent tester on.
Warm up the engine at an engine speed of 2500 rpm for approximately 90 seconds.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F sensor.
Perform the Active Test with the engine idling (press the RIGHT or LEFT button to change the fuel injection volume).
Monitor the output voltages of the air fuel ratio and heated oxygen sensors (AFS Voltage B1S1 and O2S B1S2 or AFS Voltage B2S1 and O2S B2S2) displayed on the intelligent tester.
The Control the Injection Volume for A/F sensor operation lowers the fuel injection volume by 12.5% or increases the injection volume by 25%.
Each sensor reacts in accordance with increases and decreases in the fuel injection volume.
| Tester Display (Sensor) | Injection Volume | Status | Voltage |
|---|---|---|---|
| AFS Voltage B1S1 or AFS Voltage B2S1
(Air fuel ratio sensor) |
+25% | Rich | Below 3.1 V |
| AFS Voltage B1S1 or AFS Voltage B2S1
(Air fuel ratio sensor) |
-12.5% | Lean | Higher than 3.4 V |
| O2S B1S2 or O2S B2S2
(Heated oxygen sensor) |
+25% | Rich | Higher than 0.55 V |
| O2S B1S2 or O2S B2S2
(Heated oxygen sensor) |
-12.5% | Lean | Below 0.4 V |
The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.
Following the Control the Injection Volume for A/F sensor procedure enables technicians to check and graph the voltage outputs of both the air fuel ratio and heated oxygen sensors.
To display the graph, enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / AFS Voltage B1S1 and O2S B1S2 or AFS Voltage B2S1 and O2S B2S2.
Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Check for exhaust gas leak.
No gas leak.
OK
NG
Inspect the heated oxygen sensor (See page Engine / Hybrid System>1GR-FE ENGINE CONTROL>HEATED OXYGEN SENSOR>INSPECTION).
OK
NG
Inspect the No. 1 integration relay (See page Engine / Hybrid System>1GR-FE ENGINE CONTROL>RELAY>ON-VEHICLE INSPECTION).
OK
NG
Disconnect the heated oxygen sensor connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| B29-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| B30-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector
(to Heated Oxygen Sensor Bank 1) |
| *b | Front view of wire harness connector
(to Heated Oxygen Sensor Bank 2) |
Turn the ignition switch off.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B29-1 (HT1B) - B39-12 (HT1B) | Always | Below 1 Ω |
| B29-3 (OX1B) - B36-2 (OX1B) | Always | Below 1 Ω |
| B29-4 (E2) - B36-1 (EX1B) | Always | Below 1 Ω |
| B30-1 (HT2B) - B39-13 (HT2B) | Always | Below 1 Ω |
| B30-3 (OX2B) - B36-4 (OX2B) | Always | Below 1 Ω |
| B30-4 (E2) - B36-3 (EX2B) | Always | Below 1 Ω |
| B29-1 (HT1B) or B39-12 (HT1B) - Body ground | Always | 10 kΩ or higher |
| B29-3 (OX1B) or B36-2 (OX1B) - Body ground | Always | 10 kΩ or higher |
| B30-1 (HT2B) or B39-13 (HT2B) - Body ground | Always | 10 kΩ or higher |
| B30-3 (OX2B) or B36-4 (OX2B) - Body ground | Always | 10 kΩ or higher |
OK
NG
Replace the heated oxygen sensor (See page Engine / Hybrid System>1GR-FE ENGINE CONTROL>HEATED OXYGEN SENSOR>REMOVAL).
NEXT
Refer to Confirmation Driving Pattern.
NEXT
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
Input the DTC: P0137 or P0157.
Check that DTC MONITOR is NORMAL. If DTC MONITOR is INCOMPLETE, perform the driving pattern but increase the vehicle speed.
| Display (DTC Output) | Proceed to |
|---|---|
| NORMAL
(No DTC output) |
A |
| ABNORMAL
(P0137 or P0157 detected) |
B |
A
B