Home › Vehicle Interior › THEFT DETERRENT / KEYLESS ENTRY › SMART KEY SYSTEM (for Entry Function)

SMART KEY SYSTEM (for Entry Function) > Back Door Entry Lock Function does not Operate

for Preparation Click here


DESCRIPTION

If the back door entry lock function does not operate but the back door unlock function operates, the communication line between the vehicle and electrical key transmitter is normal. The entry lock switch circuit (back door control switch → certification ECU) may be faulty.

WIRING DIAGRAM


B242195E03


INSPECTION PROCEDURE

NOTICE:
  1. The smart key system (for Entry Function) uses a multiplex communication system (LIN communication system) and the CAN communication system. Inspect the communication function by following How to Proceed with Troubleshooting (Click here). Troubleshoot the smart key system (for Entry Function) after confirming that the communication systems are functioning properly.
  2. When using the Techstream with the engine switch off to troubleshoot: Connect the Techstream to the DLC3 and turn a courtesy light switch on and off at 1.5-second intervals until communication between the Techstream and vehicle begins.
  3. Check that there are no electrical key transmitters in the vehicle.
  4. When checking the entry lock operation multiple times, the lock operation may be limited to 2 consecutive operations depending on the settings. In order to perform the entry lock operation 3 or more times, an unlock operation must be performed once (any type of unlock operation is sufficient). However, only consecutive entry lock operations are limited. Using the wireless lock or other types of lock operations, it is possible to perform consecutive lock operations without this limitation.
  5. Before replacing the certification ECU, refer to the engine immobiliser system (w/ Smart Key System) (Click here).

1.CHECK POWER DOOR LOCK OPERATION
  1. When the door control switch on the multiplex network master switch assembly is operated, check that the doors unlock and lock according to the switch operation (Click here).

    OK:
    Door locks operate normally.



NG
GO TO POWER DOOR LOCK CONTROL SYSTEM (Click here)
OK


2.READ VALUE USING TECHSTREAM (LOCK SWITCH)
  1. Using the Techstream, read the Data List (Click here).

    Smart Key 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Tr/B-Door Lock SW
    Back door lock switch / ON or OFF
    ON: Back door lock switch pushed
    OFF: Back door lock switch not pushed
    -

    OK:
    "ON" (lock switch is pushed) and "OFF" (lock switch is not pushed) appear on the screen.



NG
Go to step 3
OK

REPLACE CERTIFICATION ECU (Click here)  

3.INSPECT BACK DOOR CONTROL SWITCH (LOCK SWITCH)
B241776E02
  1. Remove the back door control switch (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    1 (SUP) - 2 (E3)
    No switch pushed
    10 kΩ or higher
    1 (SUP) - 2 (E3)
    Lock switch pushed
    Below 1 Ω



NG
REPLACE BACK DOOR CONTROL SWITCH (Click here)
OK


4.CHECK HARNESS AND CONNECTOR (BACK DOOR CONTROL SWITCH - CERTIFICATION ECU)
  1. Disconnect the W11 switch connector.

  1. Disconnect the F79 ECU connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    W11-1 (SUP) - F79-23 (TSW6)
    Always
    Below 1 Ω
    W11-2 (E3) - Body ground
    Always
    Below 1 Ω
    W11-1 (SUP) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE CERTIFICATION ECU (Click here)