SMART KEY SYSTEM (for Entry Function) > Back Door Entry Lock Function does not Operate |

| 1.CHECK POWER DOOR LOCK OPERATION |
When the door control switch on the multiplex network master switch assembly is operated, check that the doors unlock and lock according to the switch operation (Click here).
|
| ||||
| OK | |
| 2.READ VALUE USING TECHSTREAM (LOCK SWITCH) |
Using the Techstream, read the Data List (Click here).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Tr/B-Door Lock SW | Back door lock switch / ON or OFF | ON: Back door lock switch pushed OFF: Back door lock switch not pushed | - |
|
| ||||
| OK | ||
| ||
| 3.INSPECT BACK DOOR CONTROL SWITCH (LOCK SWITCH) |
![]() |
Remove the back door control switch (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 (SUP) - 2 (E3) | No switch pushed | 10 kΩ or higher |
| 1 (SUP) - 2 (E3) | Lock switch pushed | Below 1 Ω |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (BACK DOOR CONTROL SWITCH - CERTIFICATION ECU) |
Disconnect the W11 switch connector.
Disconnect the F79 ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| W11-1 (SUP) - F79-23 (TSW6) | Always | Below 1 Ω |
| W11-2 (E3) - Body ground | Always | Below 1 Ω |
| W11-1 (SUP) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||