Home › Drivetrain · TX6A AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM

DTC    P0973    Shift Solenoid "A" Control Circuit Low (Shift Solenoid Valve S1)

DTC    P0974    Shift Solenoid "A" Control Circuit High (Shift Solenoid Valve S1)

for Preparation Click here


DESCRIPTION

Based upon a signal from the TCM, the combination of shift solenoid valve (S1, S2, S3, S4, SR, SL1, SL2) changes the gear position from 1st to 6th. As a fail-safe function if the solenoid valve system is open or shorted, the TCM cuts power to all solenoids, leaving just the mechanical hydraulic circuit, requiring manual shifting.

DTC No.
DTC Detection Condition
  1. Diagnosis Condition
  2. Malfunction Status
  3. Malfunction Time
  4. Other
Trouble Area
P0973
  1. Not learning control prohibited status
  2. During shift solenoid valve S1 on signal is output, the TCM S1 output monitor value is "off".
  3. Continues for 500ms or more.
  4. 1-trip detection logic
  1. Shift solenoid valve S1
  2. Transmission wire
  3. Harness and connector
  4. TCM
P0974
  1. Not learning control prohibited status
  2. During shift solenoid valve S1 off signal is output, the TCM S1 output monitor value is "on".
  3. Continues for 500ms or more.
  4. 1-trip detection logic
  1. Shift solenoid valve S1
  2. Transmission wire
  3. Harness and connector
  4. TCM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve S1 circuit. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem and illuminates the MIL and stores the DTC.

WIRING DIAGRAM


C250709E01


INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).


HINT:
The shift solenoid valve S1 is turned on/off normally when the shift lever is in the D position:

TCM command gearshift
1st
2nd
3rd
4th
5th
6th
Shift solenoid valve S1
OFF
ON
ON
ON
ON
ON

1.INSPECT TRANSMISSION WIRE (S1)
  1. Disconnect the A18 TCM connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    A18-7(S1) - Body ground
    Ignition switch ON
    Below 1 V

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A18-7(S1) - Body ground
    20°C(68°F)
    11 to 15 Ω

  1. Connect the A18 TCM connector.



NG
Go to step 3
OK


2.REPLACE TCM
  1. Replace the TCM (Click here).


NEXT

PERFORM THE RESET MEMORY (Click here)  

3.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)
  1. Disconnect the A18 TCM connector.

  1. Disconnect the L4 transmission wire connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Condition
    Specified Condition
    L4-1(S1) - Body ground
    Ignition switch ON
    Below 1 V

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    L4-1(S1) - A18-7(S1)
    Always
    Below 1 Ω
    L4-1(S1) and A18-7(S1) - Body ground
    Always
    10 kΩ or higher

  1. Connect the A18 TCM connector.

  1. Connect the L4 transmission wire connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.INSPECT SHIFT SOLENOID VALVE S1
  1. Remove the shift solenoid valve S1 (Click here).

  1. Perform inspection of the shift solenoid valve S1 .



NG
REPLACE SHIFT SOLENOID VALVE S1 (Click here)
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)