Home › Drivetrain › TX6A (AUTOMATIC TRANSMISSION / TRANSAXLE) › AUTOMATIC TRANSMISSION SYSTEM
RM2090E _52 Drivetrain _060674 TX6A AUTOMATIC TRANSMISSION / TRANSAXLE _0297556 AUTOMATIC TRANSMISSION SYSTEM C

TX6A AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  P2719  Pressure Control Solenoid "D" Circuit Performance (SLT Solenoid)  P2720  Pressure Control Solenoid "D" Control Circuit Low  P2721  Pressure Control Solenoid "D" Control Circuit High  


DESCRIPTION

The shift solenoid valve SLT is controlled by the duty ratio as determined in advance by the transmission control computer, based upon signals from the accelerator position sensor, input speed sensor NT and output speed sensor SP2. In this way, the line pressure is adjusted to match the throttle valve opening angle and engine output. The TCM uses the revolution signals from the input speed sensor NT and output speed sensor SP2 to detect clutch and other slipping.

DTC No. DTC Detection Condition
1.

Diagnosis Condition

2.

Malfunction Status

3.

Malfunction Time

4.

Other


Trouble Area
P2719
1.

Not learning control prohibited status

2.

The difference between the shift solenoid valve SLT operational specified current and operational feedback current is 12 A or more in total.

3.

Detects "2.Malfunction Status" 2 times consecutively.

4.

1-trip detection logic


·

Shift solenoid valve SLT

·

Transmission wire

·

Harness and connector

·

TCM


P2720
1.

Not learning control prohibited status

2.

1 second or more has elapsed after turning shift solenoid valve SLT off.

The shift solenoid valve SLT operational feedback voltage is 0.018 V or less.

3.

Detects malfunction that continues for 100 ms or more 5 times consecutively.

4.

1-trip detection logic


·

Shift solenoid valve SLT

·

Transmission wire

·

Harness and connector

·

TCM


P2721
1.

Not learning control prohibited status

2.

1 second or more has elapsed after turning shift solenoid valve SLT on.

The shift solenoid valve SLT operational feedback voltage is 0.257 V or more.

3.

Detects malfunction that continues for 100 ms or more 5 times consecutively.

4.

1-trip detection logic


·

Shift solenoid valve SLT

·

Transmission wire

·

Harness and connector

·

TCM



MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit or feedback stuck is detected, the TCM interprets this as a fault. The TCM will turn on the MIL and store the DTC.

WIRING DIAGRAM

C250701E25
0.99,1.469 2.542,1.667 1.552,0.198 10 false Shift Solenoid Valve SLT 5.354,3.073 5.677,3.281 0.323,0.208 10 false TCM 4.885,2.01 5.354,2.177 0.469,0.167 10 false 9 5.365,2.917 5.646,3.115 0.281,0.198 10 false A18 5.177,2.104 5.646,2.271 0.469,0.167 10 false SLT- 4.896,0.802 5.365,0.969 0.469,0.167 10 false 4 5.167,1 6.052,1.188 0.885,0.188 10 false SLT+ 2.833,0.792 3.302,0.958 0.469,0.167 10 false 13 2.865,2.01 3.333,2.177 0.469,0.167 10 false 5 0.719,2.74 1.906,2.948 1.188,0.208 10 false Transmission Wire 0.729,2.573 0.969,2.75 0.24,0.177 10 false L4 2.313,0.802 2.781,0.969 0.469,0.167 10 false SLT+ 2.323,2.01 2.792,2.177 0.469,0.167 10 false SLT-

CAUTION / NOTICE / HINT

NOTICE:

Perform the universal trip to clear permanent DTCs (See page Drivetrain>TX6A (AUTOMATIC TRANSMISSION / TRANSAXLE)>AUTOMATIC TRANSMISSION SYSTEM>DTC CHECK / CLEAR).


PROCEDURE

1.CHECK HARNESS AND CONNECTOR
a.

Disconnect the A18 TCM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
A18-4(SLT+) - A18-9(SLT-) 20°C(68°F) 5.0 to 5.6 Ω



c.

Disconnect the A18 TCM connector.



OK

2.REPLACE TCM

NG

3.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)
3.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)
a.

Disconnect the A18 TCM connector.


b.

Disconnect the L4 transmission wire connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
A18-4(SLT+) - L4-13(SLT+) Always Below 1 Ω
A18-9(SLT-) - L4-5(SLT-) Always Below 1 Ω



d.

Measure the voltage according to the value(s) in the table below.

Standard voltage:
Tester Connection Condition Specified Condition
A18-4(SLT+) - Body ground Ignition switch ON Below 1 V
A18-9(SLT-) - Body ground Ignition switch ON Below 1 V



e.

Connect the A18 TCM connector.


f.

Connect the L4 transmission wire connector.



OK

4.INSPECT SHIFT SOLENOID VALVE SLT

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

4.INSPECT SHIFT SOLENOID VALVE SLT

b.

Perform inspection of the shift solenoid valve SLT (See page Drivetrain>TX6A (AUTOMATIC TRANSMISSION / TRANSAXLE)>VALVE BODY ASSEMBLY>INSPECTION).



OK

NG