When the heater control sub-assembly is operated, the Heater relay will turn on to allow current to flow to the blower motor and then the motor will start rotating. Operating the heater control sub-assembly switches the current flow between the blower resistor and body ground, thus, shifting the operating speed of the blower motor.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Remove the heater blower motor relay.
Inspect the heater blower motor relay (See page Vehicle Interior>HEATING / AIR CONDITIONING>RELAY>ON-VEHICLE INSPECTION).
OK
NG
Disconnect the A31 blower motor with fan sub-assembly connector.
Inspect the blower motor with fan sub-assembly (See page Vehicle Interior>HEATING / AIR CONDITIONING>FRONT BLOWER MOTOR>INSPECTION).
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A65-3 - A31-2 | Always | Below 1 Ω |
| A65-3 - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the heater control sub-assembly (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING PANEL(for Manual Air Conditioning System)>DISASSEMBLY).
Inspect the heater control sub-assembly (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING PANEL(for Manual Air Conditioning System)>INSPECTION).
OK
NG
Disconnect the D23 heater control sub-assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A65-2 - D23-10 | Always | Below 1 Ω |
| A65-2 - Body ground | Always | 10 kΩ or higher |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-1 - D23-1 | Always | Below 1 Ω |
| A31-1 - Body ground | Always | 10 kΩ or higher |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D23-5(E) - Body ground | Always | Below 1 Ω |
OK
NG
Remove the blower resister (See page Vehicle Interior>HEATING / AIR CONDITIONING>BLOWER RESISTOR>REMOVAL).
Inspect the blower resistor (See page Vehicle Interior>HEATING / AIR CONDITIONING>BLOWER RESISTOR>INSPECTION).
OK
NG
Disconnect the A26 blower resister connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D23-3(M&M1) - A26-2(M&M1) | Always | Below 1 Ω |
| D23-6(M2) - A26-3(M2) | Always | Below 1 Ω |
| D23-3(M&M1) - Body ground | Always | 10 kΩ or higher |
| D23-6(M2) - Body ground | Always | 10 kΩ or higher |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A31-1 - A26-1(H) | Always | Below 1 Ω |
| A31-1 - Body ground | Always | 10 kΩ or higher |
OK
NG
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A26-4(L) - Body ground | Always | Below 1 Ω |
OK
NG