To control the cooling fan, the ECM turns on or off the cooling fan relay based on the engine coolant temperature, air conditioning switch, refrigerant pressure, engine speed and vehicle speed signals.
Refer to System Diagram (See page Engine / Hybrid System>3SZ-VE COOLING>COOLING FAN SYSTEM>SYSTEM DIAGRAM).
Inspect the fuses for circuits related to this system before performing the following procedure.
| *1 | Engine Room Relay Block |
| *2 | RAD Relay |
Remove the RAD relay from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| RAD relay terminal 3 - Body ground | Always | 11 to 14V |
Reinstall the RAD relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the ignition or starter switch assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E28-5 (AM2) - Body ground | Always | 11 to 14V |
Reconnect the ignition or starter switch assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the RAD relay.
Click hereEngine / Hybrid System>3SZ-VE COOLING>RELAY>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the ignition or starter switch assembly.
Click hereEngine / Hybrid System>3SZ-VE STARTING>IGNITION SWITCH>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the ignition or starter switch assembly connector.
Remove the RAD relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E28-6 (IG2) - RAD relay terminal 2 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E28-6 (IG2) or RAD relay terminal 2 - Body ground | Always | 10 kΩ or higher |
Reinstall the RAD relay.
Reconnect the ignition or starter switch assembly connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cooling fan motor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A6-1 - Body ground | Always | Below 1 Ω |
Reconnect the cooling fan motor connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the cooling fan motor.
Click hereEngine / Hybrid System>3SZ-VE COOLING>COOLING FAN MOTOR>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the cooling fan motor connector.
Remove the RAD relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A6-2 - RAD relay terminal 5 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A6-2 or RAD relay terminal 5 - Body ground | Always | 10 kΩ or higher |
Reinstall the RAD relay.
Reconnect the cooling fan motor connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the RAD relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E3-16 (FAN) - RAD relay terminal 1 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E3-16 (FAN) or RAD relay terminal 1 - Body ground | Always | 10 kΩ or higher |
Reconnect the ECM connector.
Reinstall the RAD relay.
| Proceed to |
|---|
| OK |
| NG |
OK
NG