To control the cooling fan, the ECM turns on and off the cooling fan relay based on the engine coolant temperature, air conditioning switch, refrigerant pressure, engine speed and vehicle speed signals.
On vehicles equipped with a cooling fan resistor, the ECM turns the RAD No. 2 relay on and off to control the cooling fan speed in 2 stages.
Refer to System Diagram (See page Engine / Hybrid System>3SZ-VE COOLING>COOLING FAN SYSTEM>SYSTEM DIAGRAM).
Inspect the fuses for circuits related to this system before performing the following procedure.
| *1 | Engine Room Relay Block |
| *2 | RAD Relay Holder |
Remove the RAD relay from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| RAD relay terminal 3 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the E28 ignition or starter switch assembly connector.
| *a | Front view of wire harness connector
(to Ignition or Starter Switch Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E28-5 (AM2) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the ignition or starter switch assembly.
Click hereEngine / Hybrid System>3SZ-VE STARTING>IGNITION SWITCH>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
w/o cooling fan resister
Inspect the RAD relay.
Click hereEngine / Hybrid System>3SZ-VE COOLING>RELAY>ON-VEHICLE INSPECTION
w/ cooling fan resister
Inspect the RAD relay.
Click hereEngine / Hybrid System>3SZ-VE COOLING>RELAY>ON-VEHICLE INSPECTION
Inspect the RAD No. 2 relay.
Click hereEngine / Hybrid System>3SZ-VE COOLING>RELAY>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the E28 ignition or starter switch assembly connector.
w/o cooling fan resister
Remove the RAD relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E28-6 (IG2) - RAD relay terminal 2 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E28-6 (IG2) or RAD relay terminal 2 - Body ground | Always | 10 kΩ or higher |
w/ cooling fan resister
Remove the RAD relay and RAD No. 2 relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E28-6 (IG2) - RAD relay terminal 2 | Always | Below 1 Ω |
| E28-6 (IG2) - RAD No. 2 relay terminal 2 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E28-6 (IG2) - Body ground | Always | 10 kΩ or higher |
| RAD relay terminal 2 - Body ground | Always | 10 kΩ or higher |
| RAD No. 2 relay terminal 2 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the cooling fan motor.
Click hereEngine / Hybrid System>3SZ-VE COOLING>COOLING FAN MOTOR>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A6 cooling fan motor connector.
Remove the RAD relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A6-2 - RAD relay terminal 5 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A6-2 or RAD relay terminal 5 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the RAD relay from the engine room relay block.
Disconnect the E3 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E3-16 (FAN) - RAD relay terminal 1 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E3-16 (FAN) or RAD relay terminal 1 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Confirm the vehicle type.
| Result | Proceed to |
|---|---|
| w/o cooling fan resister | A |
| w/ cooling fan resister | B |
A
B
Disconnect the A6 cooling fan motor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A6-1 - Body ground | Always | Below 1 Ω |
| Result | Proceed to |
|---|---|
| OK (for LHD) | A |
| OK (for RHD) | B |
| NG | C |
A
B
C
Disconnect the A6 cooling fan motor connector.
Disconnect the A12 cooling fan resister connector.
Remove the RAD No. 2 relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A6-1 - RAD No. 2 relay terminal 5 | Always | Below 1 Ω |
| A6-1 - A12-2 (+) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A6-1 - Body ground | Always | 10 kΩ or higher |
| A12-2 (+) - Body ground | Always | 10 kΩ or higher |
| RAD No. 2 relay terminal 5 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the cooling fan resister.
Click hereEngine / Hybrid System>3SZ-VE COOLING>COOLING FAN RESISTOR>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the RAD No. 2 relay from the engine room relay block.
Remove the A12 cooling fan resister connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| RAD No. 2 relay terminal 3 - Body ground | Always | Below 1 Ω |
| A12-1(-) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the RAD No. 2 relay from the engine room relay block.
Disconnect the E3 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E3-5 (FAN2) - RAD No. 2 relay terminal 1 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E3-5 (FAN2) or RAD No. 2 relay terminal 1 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG