Shifting from 1st to 4th is performed in combination with ON and OFF operation of the shift solenoid valves SL1, SL2, SL3, SL, SLU and SLT which is controlled by the ECM. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (Fail-safe function).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | Memory | Note |
|---|---|---|---|---|---|---|---|
| P0748 | Shift Solenoid "A" Electrical | 1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
1.
During energization of shift solenoid valve SL1. 2.
An open or short in the shift solenoid valve SL1 circuit is detected. 3.
1 seconds 4.
1-trip detection logic |
·
Open or short in shift solenoid valve SL1 circuit ·
Transmission wire (shift solenoid valve SL1) ·
Shift solenoid valve SL1 (transmission valve body assembly) ·
ECM |
Come on | Blinks | DTC stored | - |
| P0778 | Shift Solenoid "B" Electrical | 1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
1.
During energization of shift solenoid valve SL2. 2.
An open or short in the shift solenoid valve SL2 circuit is detected. 3.
1 seconds 4.
1-trip detection logic |
·
Open or short in shift solenoid valve SL2 circuit ·
Transmission wire (shift solenoid valve SL2) ·
Shift solenoid valve SL2 (transmission valve body assembly) ·
ECM |
Come on | Blinks | DTC stored | - |
| P0798 | Shift Solenoid "C" Electrical | 1. Diagnosis Condition 2. Malfunction Status 3. Malfunction Time 4. Other
1.
During energization of shift solenoid valve SL3. 2.
An open or short in the shift solenoid valve SL3 circuit is detected. 3.
1 seconds 4.
1-trip detection logic |
·
Open or short in shift solenoid valve SL3 circuit ·
Transmission wire (shift solenoid valve SL3) ·
Shift solenoid valve SL3 (transmission valve body assembly) ·
ECM |
Come on | Blinks | DTC stored | - |
MIL:"Comes on" means the MIL (Malfunction Indicator Light) illuminates.
Memory:"DTC stored" means the ECM stores the trouble code if the ECU detects the DTC detection condition.
Connect the GTS or Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the GTS or Techstream on.
Enter the following menus: Powertrain / A/T / Trouble Codes.
When not using the GTS or Techstream, refer to DTC CHECK / CLEAR.
Click hereDrivetrain>A4R AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>DTC CHECK / CLEAR
Read the DTC using the GTS or Techstream.
| Display (DTC Output) | Proceed to |
|---|---|
| DTC P0748 is output | A |
| DTC P0778 is output | B |
| DTC P0798 is output | C |
A
B
C
| *a | Component without harness connected
(Transmission Wire) |
Disconnect the C45 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 13 (H7) - 6 (H1) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 13 (H7) - Body ground | Always | 10 kΩ or higher |
| 6 (H1) - Body ground | Always | 10 kΩ or higher |
Reconnect the C45 transmission wire connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the C45 transmission wire connector.
Disconnect the C50 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C45-13 (H7) - C50-24 (B1+) | Always | Below 1 Ω |
| C45-6 (H1) - C50-25 (B1-) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C45-13 (H7) or C50-24 (B1+) - Body ground and other terminals | Always | 10 kΩ or higher |
| C45-6 (H1) or C50-25 (B1-) - Body ground and other terminals | Always | 10 kΩ or higher |
Reconnect the C50 ECM connector.
Reconnect the C45 transmission wire connector.
| Result | Proceed to |
|---|---|
| OK (for 1NR-VE) | A |
| OK (for 2NR-VE) | B |
| NG | C |
A
B
C
| *a | Component without harness connected
(Shift Solenoid Valve SL1) |
Remove the shift solenoid valve SL1.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
Never directly apply battery voltage to the solenoid valve connector (Do not allow a current of 1 A or more to flow). Perform the operation check via the specified bulb (resistance).
If a current of 1 A or more flows, the characteristic of the solenoid valve changes.
The solenoid valve makes an operating sound.
| proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Transmission Wire) |
Disconnect the C45 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 12 (H8) - 5 (H2) | 20°C (68°F) | 5.1 to 5.5 Ω |
| 12 (H8) - Body ground | Always | 10 kΩ or higher |
| 5 (H2) - Body ground | Always | 10 kΩ or higher |
Reconnect the C45 transmission wire connector.
| proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the C45 transmission wire connector.
Disconnect the C50 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C45-12 (H8) - C50-26 (C2+) | Always | Below 1 Ω |
| C45-5 (H2) - C50-27 (C2-) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C45-12 (H8) or C50-26 (C2+) - Body ground and other terminals | Always | 10 kΩ or higher |
| C45-5 (H2) or C50-27 (C2-) - Body ground and other terminals | Always | 10 kΩ or higher |
Reconnect the C50 ECM connector.
Reconnect the C45 transmission wire connector.
| Result | Proceed to |
|---|---|
| OK (for 1NR-VE) | A |
| OK (for 2NR-VE) | B |
| NG | C |
A
B
C
| *a | Component without harness connected
(Shift Solenoid Valve SL2) |
Remove the shift solenoid valve SL2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.1 to 5.5 Ω |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
Never directly apply battery voltage to the solenoid valve connector (Do not allow a current of 1 A or more to flow). Perform the operation check via the specified bulb (resistance).
If a current of 1 A or more flows, the characteristic of the solenoid valve changes.
The solenoid valve makes an operating sound.
| proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Transmission Wire) |
Disconnect the C45 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 11 (H9) - 4 (H3) | 20°C (68°F) | 5.1 to 5.5 Ω |
| 11 (H9) - Body ground | Always | 10 kΩ or higher |
| 4 (H3) - Body ground | Always | 10 kΩ or higher |
Reconnect the C45 transmission wire connector.
| proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the C45 transmission wire connector.
Disconnect the C50 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C45-11 (H9) - C50-28 (C3+) | Always | Below 1 Ω |
| C45-4 (H3) - C50-29 (C3-) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C45-11 (H9) or C50-28 (C3+) - Body ground and other terminals | Always | 10 kΩ or higher |
| C45-4 (H3) or C50-29 (C3-) - Body ground and other terminals | Always | 10 kΩ or higher |
Reconnect the C50 ECM connector.
Reconnect the C45 transmission wire connector.
| Result | Proceed to |
|---|---|
| OK (for 1NR-VE) | A |
| OK (for 2NR-VE) | B |
| NG | C |
A
B
C
| *a | Component without harness connected
(Shift Solenoid Valve SL3) |
Remove the shift solenoid valve SL3.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.1 to 5.5 Ω |
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
Never directly apply battery voltage to the solenoid valve connector (Do not allow a current of 1 A or more to flow). Perform the operation check via the specified bulb (resistance).
If a current of 1 A or more flows, the characteristic of the solenoid valve changes.
The solenoid valve makes an operating sound.
| proceed to |
|---|
| OK |
| NG |
OK
NG