Home › Engine / Hybrid System › 2NR-VE ENGINE CONTROL › SFI SYSTEM(w/o Air Fuel Ratio Sensor) › from 2015.08
RM19Y0E _51 Engine / Hybrid System _042272 2NR-VE ENGINE CONTROL _0196163 SFI SYSTEM(w/o Air Fuel Ratio Sensor) C

2NR-VE ENGINE CONTROL  SFI SYSTEM(w/o Air Fuel Ratio Sensor)  P0135  Oxygen Sensor Heater (Front) System Malfunction  


DESCRIPTION

Refer to DTC P0134.

Click hereEngine / Hybrid System>2NR-VE ENGINE CONTROL>SFI SYSTEM(w/o Air Fuel Ratio Sensor)>P0134

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0135 Oxygen Sensor Heater (Front) System Malfunction Open or short in oxygen sensor heater circuit for 1.28 seconds or more
(1 trip detection logic)
·

Open or short in oxygen sensor heater circuit

·

Oxygen sensor heater

·

ECM


Comes on DTC stored

CAUTION / NOTICE / HINT

HINT:

Read freeze frame data using the GTS. Freeze frame data record the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data, from the time the malfunction occurred.


PROCEDURE

1.CHECK HARNESS AND CONNECTOR (OXYGEN SENSOR - NO. 1 INTEGRATION RELAY)
a.

Disconnect the oxygen sensor connector.


b.

Remove the No. 1 integration relay connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connections Condition Specified Conditions
C22-2 (HTR+) - 1J-3 Always Below 1 Ω
C22-2 (HTR+) or 1J-3 - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (POWER SOURCE OF OXYGEN SENSOR)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

2.CHECK HARNESS AND CONNECTOR (POWER SOURCE OF OXYGEN SENSOR)
a.
A217280C83
0.635,1.979 1.125,2.271 0.49,0.292 1.969,2.042 2.542,1.865 true 0.208,0.281 0.469,0.49 0.26,0.208 10 false *a 2.583,1.771 3.021,2.021 0.438,0.25 10 false HTR+ 0.76,2.063 1.135,2.302 0.375,0.24 10 false C22
*a Front view of wire harness connector
(to Oxygen Sensor)


Turn the ignition switch to ON.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connections Switch Condition Specified Conditions
C22-2 (HTR+) - Body ground Ignition switch ON 11 to 14 V


Result:
Proceed to
OK
NG




OK

3.INSPECT OXYGEN SENSOR (HEATER RESISTANCE)

NG

3.INSPECT OXYGEN SENSOR (HEATER RESISTANCE)
a.

Inspect the oxygen sensor.

Click hereEngine / Hybrid System>2NR-VE ENGINE CONTROL>HEATED OXYGEN SENSOR>INSPECTION

Result:
Proceed to
OK
NG




OK

4.CHECK HARNESS AND CONNECTOR (ECM - OXYGEN SENSOR)

NG

4.CHECK HARNESS AND CONNECTOR (ECM - OXYGEN SENSOR)
a.

Disconnect the ECM connector.


b.

Disconnect the oxygen sensor connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connections Condition Specified Conditions
C50-8 (OXH1) - C22-1 (HTR-) Always Below 1 Ω
C50-8 (OXH1) or C22-1 (HTR-) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR