The ECM turns on or off the fan relays using signals calculated from the engine coolant temperature, air conditioning switch (on/off), air conditioning refrigerant pressure, engine speed and vehicle speed signals.
The ECM switches the circuit of the cooling fan motors between series and parallel by turning on or off the fan relays in order to control the speed of the cooling fan motors in two steps.
Refer to the System Diagram.
Click hereEngine / Hybrid System>2ZR-FXE (COOLING)>COOLING FAN SYSTEM>SYSTEM DIAGRAM
Inspect the fuses for circuits related to this system before performing the following procedure.
Before replacing the ECM, refer to Service Bulletin.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Powertrain / Engine / Active Test / Control the Engine Cooling Fan
| Tester Display |
|---|
| Control the Engine Cooling Fan |
Perform the Active Test according to the display on the GTS.
| Active Tester Operation | Fan Operation |
|---|---|
| HIGH | Cooling fans high speed operate |
| LOW | Cooling fans low speed operate |
| OFF | Cooling fans stop |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A38 ECM connector.
Turn the power switch on (IG).
| *a | Front view of wire harness connector
(to ECM) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A38-8 (FANH) - Body ground | Power switch on (IG) | 11 to 14 V |
| A38-7 (FANL) - Body ground | Power switch on (IG) | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the FAN NO. 1 relay and FAN NO. 3 relay from the No. 2 relay block.
| *1 | No. 2 Relay Block |
| *2 | FAN NO. 1 Relay |
| *3 | FAN NO. 3 Relay |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (FAN NO. 1 relay) - Body ground | Always | 11 to 14 V |
| 3 (FAN NO. 3 relay) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the FAN NO. 1 relay, FAN NO. 2 relay and FAN NO. 3 relay.
Click hereEngine / Hybrid System>2ZR-FXE (COOLING)>RELAY>ON-VEHICLE INSPECTION
| Result | Proceed to |
|---|---|
| OK | A |
| NG (FAN NO. 1 relay) | B |
| NG (FAN NO. 2 relay) | C |
| NG (FAN NO. 3 relay) | D |
A
B
C
D
Remove the FAN NO. 2 relay from the No. 2 relay block.
| *1 | No. 2 Relay Block |
| *2 | FAN NO. 2 Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (FAN NO. 2 relay) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the cooling fan motor RH.
Click hereEngine / Hybrid System>2ZR-FXE (COOLING)>COOLING FAN MOTOR>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A4 cooling fan motor RH connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A4-1 - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A4 cooling fan motor RH connector.
Remove the FAN NO. 1 relay and FAN NO. 2 relay from the No. 2 engine room relay block.
| *1 | No. 2 Engine Room Relay Block |
| *2 | FAN NO. 1 Relay |
| *3 | FAN NO. 2 Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A4-2 - 5 (FAN NO. 1 relay) | Always | Below 1 Ω |
| A4-2 - 4 (FAN NO. 2 relay) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A4-2 or 5 (FAN NO. 1 relay) - Body ground | Always | 10 kΩ or higher |
| A4-2 or 4 (FAN NO. 2 relay) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the cooling fan motor LH.
Click hereEngine / Hybrid System>2ZR-FXE (COOLING)>COOLING FAN MOTOR>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A5 cooling fan motor LH connector.
Remove the FAN NO. 2 relay and FAN NO. 3 relay from the No. 2 engine room relay block.
| *1 | No. 2 Engine Room Relay Block |
| *2 | FAN NO. 2 Relay |
| *3 | FAN NO. 3 Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A5-1 - 3 (FAN NO. 2 relay) | Always | Below 1 Ω |
| A5-2 - 5 (FAN NO. 3 relay) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A5-1 or 3 (FAN NO. 2 relay) - Body ground | Always | 10 kΩ or higher |
| A5-2 or 5 (FAN NO. 3 relay) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the FAN NO. 1 relay and FAN NO. 2 relay from the No. 2 engine room relay block.
| *1 | No. 2 Engine Room Relay Block |
| *2 | FAN NO. 1 Relay |
| *3 | FAN NO. 2 Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (FAN NO. 1 relay) - 2 (FAN NO. 2 relay) | Always | Below 1 Ω |
| 2 (FAN NO. 1 relay) - 1 (FAN NO. 2 relay) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (FAN NO. 1 relay) or 2 (FAN NO. 2 relay) - Body ground | Always | 10 kΩ or higher |
| 2 (FAN NO. 1 relay) or 1 (FAN NO. 2 relay) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the FAN NO. 1 relay, FAN NO. 2 relay and FAN NO. 3 relay.
Click hereEngine / Hybrid System>2ZR-FXE (COOLING)>RELAY>ON-VEHICLE INSPECTION
| Result | Proceed to |
|---|---|
| OK | A |
| NG (FAN NO. 1 relay) | B |
| NG (FAN NO. 2 relay) | C |
| NG (FAN NO. 3 relay) | D |
A
B
C
D
Remove the FAN NO. 1 relay, FAN NO. 2 relay and FAN NO. 3 relay from the No. 2 engine room relay block.
| *1 | No. 2 Engine Room Relay Block |
| *2 | FAN NO. 1 Relay |
| *3 | FAN NO. 2 Relay |
| *4 | FAN NO. 3 Relay |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (FAN NO. 1 relay) - Body ground | Always | 11 to 14 V |
| 2 (FAN NO. 2 relay) - Body ground | Always | 11 to 14 V |
| 1 (FAN NO. 3 relay) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the FAN NO. 1 relay, FAN NO. 2 relay and FAN NO. 3 relay from the No. 2 relay block.
Remove the No. 1 integration relay from the No. 1 engine room relay block and No. 1 junction block assembly.
Disconnect the 1B No. 1 integration relay connector.
| *1 | No. 2 Relay Block |
| *2 | FAN NO. 1 Relay |
| *3 | FAN NO. 2 Relay |
| *4 | FAN NO. 3 Relay |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (FAN NO. 1 relay) - 1B-4 | Always | Below 1 Ω |
| 2 (FAN NO. 2 relay) - 1B-4 | Always | Below 1 Ω |
| 1 (FAN NO. 3 relay) - 1B-4 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (FAN NO. 1 relay) or 1B-4 - Body ground | Always | 10 kΩ or higher |
| 2 (FAN NO. 2 relay) or 1B-4 - Body ground | Always | 10 kΩ or higher |
| 1 (FAN NO. 3 relay) or 1B-4 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the No. 1 integration relay.
Click herePower Source / Network>POWER DISTRIBUTION>INTEGRATION RELAY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the No. 1 integration relay from the No. 1 engine room relay block.
Disconnect the 1B No. 1 integration relay connector.
| *a | Front view of wire harness connector
(to No. 1 Integration Relay) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1B-3 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the No. 1 integration relay from the No. 1 engine room relay block.
Disconnect the 1B No. 1 integration relay connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1B-5 - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the A38 ECM connector.
Disconnect the 1B No. 1 integration relay connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A38-46 (MREL) - 1B-6 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A38-46 (MREL) or 1B-6 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG