Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Manual Air Conditioning System)
RM32H0E _58 Vehicle Interior _059841 HEATING / AIR CONDITIONING _0298709 AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  B1442  Air Inlet Damper Control Servo Motor Circuit  


DESCRIPTION

According to signals from the air conditioning amplifier assembly that are based on user operation or air conditioning system control, the blower motor damper servo sub-assembly (fresh/recirculation) actuates the servo motor to switch between inside and outside air intake.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
B1442 Air Inlet Damper Control Servo Motor Circuit Any of the following conditions is met:
·

No. 1 blower motor damper servo sub-assembly (fresh/recirculation) drive terminal is open circuit

·

No. 1 blower motor damper servo sub-assembly (fresh/recirculation) drive terminal is short circuit


·

No. 1 blower motor damper servo sub-assembly (fresh/recirculation)

·

Air conditioning harness assembly (heater radiator unit sub-assembly)

·

Air conditioning harness assembly (blower assembly)

·

Air conditioning amplifier assembly


Memorized
(30 seconds or more)*

*: The air conditioning amplifier assembly stores this DTC if the malfunction has occurred for the period of time indicated in the brackets.


DTC Detection Conditions
Vehicle Condition
Pattern 1 Pattern 2
Diagnosis Condition Ignition switch ON ○ ○
Malfunction Status No. 1 blower motor damper servo sub-assembly (fresh/recirculation) drive terminal is open circuit ○ -
No. 1 blower motor damper servo sub-assembly (fresh/recirculation) drive terminal is short circuit - ○
Detection Time 30 seconds or more 30 seconds or more
Number of Trips 1 trip 1 trip

HINT:

DTC will be output when conditions for either of the patterns in the table above are met.


WIRING DIAGRAM

E357694E01
0.604,0.26 1.375,0.458 0.771,0.198 10 false Micon 0.292,0.656 1.417,0.854 1.125,0.198 10 false Power Supply IC 0.542,2.125 0.823,2.323 0.281,0.198 10 false IC 1.156,1.292 1.604,1.479 0.448,0.188 10 false A1AI 1.208,1.76 1.552,1.938 0.344,0.177 10 false BAI 0.969,2.26 1.417,2.448 0.448,0.188 10 false Micon 1.135,2.771 1.615,2.99 0.479,0.219 10 false A2AI 1.135,3.219 1.573,3.406 0.438,0.188 10 false B1AI 1.135,3.833 1.51,4.031 0.375,0.198 10 false B2AI 0.073,4.448 0.844,4.646 0.771,0.198 10 false F7A 0.073,4.604 1.635,5.042 1.563,0.438 10 false Air Conditioning Amplifier Assembly 1.771,4.479 3,5.24 1.229,0.76 10 false Air Conditioning Harness Assembly (Heater Radiator Unit Sub-assembly) 3.167,4.469 4.354,5.229 1.188,0.76 10 false Air Conditioning Harness Assembly (Blower Assembly) 4.792,4.594 6.813,5.01 2.021,0.417 10 false No. 1 Blower Damper Servo Sub-assembly (Fresh/Recirculation) 4.802,4.438 5.573,4.635 0.771,0.198 10 false AI 1.542,1.292 1.75,1.479 0.208,0.188 10 false 9 3.021,1.667 3.229,1.854 0.208,0.188 10 false 6 1.531,1.76 1.74,1.948 0.208,0.188 10 false 13 1.552,2.76 1.76,2.948 0.208,0.188 10 false 3 1.542,3.219 1.75,3.406 0.208,0.188 10 false 10 1.563,3.844 1.771,4.031 0.208,0.188 10 false 2 3.021,1.396 3.229,1.583 0.208,0.188 10 false w 3.031,1.865 3.24,2.052 0.208,0.188 10 false w 3.031,2.833 3.24,3.021 0.208,0.188 10 false w 3.021,3.292 3.229,3.479 0.208,0.188 10 false w 3.021,3.917 3.229,4.104 0.208,0.188 10 false w 3.01,1.198 3.219,1.385 0.208,0.188 10 false 1 3.031,2.635 3.24,2.823 0.208,0.188 10 false 2 3.031,3.115 3.24,3.302 0.208,0.188 10 false 3 3.031,3.729 3.208,3.938 0.177,0.208 10 false 4 4.385,1.292 4.563,1.5 0.177,0.208 10 false 1 4.396,1.76 4.573,1.969 0.177,0.208 10 false 2 4.396,2.74 4.573,2.948 0.177,0.208 10 false 3 4.385,3.219 4.563,3.427 0.177,0.208 10 false 4 4.375,3.844 4.552,4.052 0.177,0.208 10 false 6

CAUTION / NOTICE / HINT

HINT:

When installing the damper servo motor, make sure to install it correctly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT (for VALEO Made)>REASSEMBLY


PROCEDURE

1.PERFORM ACTIVE TEST USING GTS (AIR INLET)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Inlet No. 1 blower damper servo sub-assembly target position Min.: 0
Max.: 100
Operates between
0 to 100%
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Inlet
50004 121 201
OK:

No. 1 blower motor damper servo sub-assembly (fresh/recirculation) operates normally.



Result:
Result Proceed to
NG (When troubleshooting according to Problem Symptoms Table) A
NG (When troubleshooting according to the DTC) B
OK (When troubleshooting according to Problem Symptoms Table) C
OK (When troubleshooting according to the DTC) D



A

2.INSPECT NO. 1 BLOWER DAMPER SERVO SUB- ASSEMBLY (FRESH/RECIRCULATION) (MOTOR, LINK, DAMPER)

B

4.INSPECT AIR CONDITIONING HARNESS ASSEMBLY (HEATER RADIATOR UNIT SUB-ASSEMBLY)

C

D

8.CHECK FOR DTC
2.INSPECT NO. 1 BLOWER DAMPER SERVO SUB- ASSEMBLY (FRESH/RECIRCULATION) (MOTOR, LINK, DAMPER)
a.

Check for a wire harness caught between the links of the motors and dampers.

OK:

No wire harnesses are caught between the links of the motors and dampers.



Result:
Proceed to
OK
NG



OK

3.INSPECT BLOWER ASSEMBLY (DAMPER)

NG

REMOVE PINCHED WIRE HARNESS

3.INSPECT BLOWER ASSEMBLY (DAMPER)
a.

Remove the No. 1 blower damper servo sub-assembly (fresh/recirculation).

Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT (for VALEO Made)>DISASSEMBLY


b.

Operate the dampers by hand.

OK:

The dampers are easily operated by hand.



Result:
Proceed to
OK
NG



OK

4.INSPECT AIR CONDITIONING HARNESS ASSEMBLY (HEATER RADIATOR UNIT SUB-ASSEMBLY)

NG

REPLACE NO. 1 BLOWER DAMPER SERVO SUB- ASSEMBLY (FRESH/RECIRCULATION)

4.INSPECT AIR CONDITIONING HARNESS ASSEMBLY (HEATER RADIATOR UNIT SUB-ASSEMBLY)
a.

Remove the air conditioning harness assembly (heater radiator unit sub-assembly).

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING UNIT (for VALEO Made)>DISASSEMBLY


b.
E357702C05
1.479,0.271 1.917,0.573 0.438,0.302 0.958,2.677 1.302,2.927 0.344,0.25 2.063,1.313 2.823,0.875 true 1.333,1.802 1.646,1.354 true 0.74,1.75 1.042,1.323 true 1.76,1.823 1.76,1.344 true 0.948,1.323 0.531,0.979 true 0.354,0.292 0.667,0.49 0.313,0.198 10 false *a 0.792,2.26 1.104,2.458 0.313,0.198 10 false *b 1.063,2.719 1.24,2.938 0.177,0.219 10 false w 1.563,0.333 1.958,0.531 0.396,0.198 10 false F7A 0.219,0.854 0.583,1.052 0.365,0.198 10 false B2AI 0.573,1.76 0.958,1.969 0.385,0.208 10 false A2AI 1.135,1.844 1.521,2.052 0.385,0.208 10 false A1AI 1.635,1.854 2.021,2.063 0.385,0.208 10 false B1AI 2.885,0.76 3.271,0.969 0.385,0.208 10 false BAI
*a Front view of wire harness connector
(to Air Conditioning Amplifier Assembly)
*b Front view of wire harness connector
(to Air Conditioning Harness Assembly (blower assembly))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F7A-13 (BAI) - w-6 Always Below 1 Ω
F7A-9 (A1AI) - w-1 Always Below 1 Ω
F7A-3 (A2AI) - w-2 Always Below 1 Ω
F7A-10 (B1AI) - w-3 Always Below 1 Ω
F7A-2 (B2AI) - w-4 Always Below 1 Ω
F7A-13 (BAI) or w-6 - Body ground Always 10 kΩ or higher
F7A-9 (A1AI) or w-1 - Body ground Always 10 kΩ or higher
F7A-3 (A2AI) or w-2 - Body ground Always 10 kΩ or higher
F7A-10 (B1AI) or w-3 - Body ground Always 10 kΩ or higher
F7A-2 (B2AI) or w-4 - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

5.INSPECT AIR CONDITIONING HARNESS ASSEMBLY (BLOWER ASSEMBLY)

NG

REPLACE AIR CONDITIONING HARNESS ASSEMBLY (HEATER RADIATOR UNIT SUB-ASSEMBLY

5.INSPECT AIR CONDITIONING HARNESS ASSEMBLY (BLOWER ASSEMBLY)
a.

Remove the air conditioning harness assembly (blower assembly).

Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT (for VALEO Made)>DISASSEMBLY


b.
E361413C03
1.417,0.25 1.917,0.5 0.5,0.25 1.385,2.083 1.771,2.333 0.385,0.25 1.802,3.021 2.375,2.469 true 1.792,3.177 2.354,2.833 true 1.802,3.281 2.458,3.146 true 1.104,2.771 1.625,3.052 true 1.115,3.219 1.635,3.281 true 0.74,0.125 1.052,0.281 0.313,0.156 10 false *a 0.927,2.146 1.24,2.302 0.313,0.156 10 false *b 1.625,0.26 1.938,0.417 0.313,0.156 10 false w 1.49,2.125 1.802,2.281 0.313,0.156 10 false AI 2.427,2.323 2.875,2.531 0.448,0.208 10 false A1AI 2.396,2.688 2.844,2.896 0.448,0.208 10 false BAI 2.49,3.052 2.938,3.26 0.448,0.208 10 false A2AI 0.792,2.646 1.24,2.854 0.448,0.208 10 false B1AI 0.802,3.125 1.25,3.333 0.448,0.208 10 false B2AI
*a Front view of wire harness connector
(from Air Conditioning Harness Assembly (Heater Radiator Unit Sub-assembly))
*b Front view of wire harness connector
(to No. 1 blower damper servo sub-assembly (fresh/recirculation))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
w-1 - AI-1 (A1AI) Always Below 1 Ω
w-6 - AI-2 (BAI) Always Below 1 Ω
w-2 - AI-3 (A2AI) Always Below 1 Ω
w-3 - AI-4 (B1AI) Always Below 1 Ω
w-4 - AI-6 (B2AI) Always Below 1 Ω
w-1 or AI-1 (A1AI) - Body ground Always 10 kΩ or higher
w-6 or AI-2 (BAI) - Body ground Always 10 kΩ or higher
w-2 or AI-3 (A2AI) - Body ground Always 10 kΩ or higher
w-3 or AI-4 (B1AI) - Body ground Always 10 kΩ or higher
w-4 or AI-6 (B2AI) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

6.REPLACE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (FRESH/RECIRCULATION)

NG

REPLACE AIR CONDITIONING HARNESS ASSEMBLY (BLOWER ASSEMBLY)

6.REPLACE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (FRESH/RECIRCULATION)
a.

Replace the No. 1 blower damper servo sub-assembly (fresh/recirculation) with a new one or the No. 2 air conditioning radiator damper servo sub-assembly (mode switching) if it is functioning properly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT (for VALEO Made)>DISASSEMBLY


Result:
Proceed to
NEXT



NEXT

7.PERFORM ACTIVE TEST USING GTS (AIR INLET CURRENT POSITION)
7.PERFORM ACTIVE TEST USING GTS (AIR INLET CURRENT POSITION)
a.

Connect the GTS to the DLC3.


b.

Turn the ignition switch ON.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Inlet No. 1 blower damper servo sub-assembly target position Min.: 0
Max.: 100
Operates between
0 to 100%
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Inlet
50004 121 201
OK:

No. 1 blower motor damper servo sub-assembly (fresh/recirculation) operates normally.



Result:
Proceed to
OK
NG



OK

REPLACE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (FRESH/RECIRCULATION)

NG

8.CHECK FOR DTC
8.CHECK FOR DTC
a.

Clear the DTCs.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Manual Air Conditioning System)>DTC CHECK / CLEAR

Body Electrical > Air Conditioner > Clear DTCs
50002 121

b.

Check for DTCs.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Manual Air Conditioning System)>DTC CHECK / CLEAR

Body Electrical > Air Conditioner > Trouble Codes
50001 121

Result:
Result Proceed to
DTCs are not output A
DTCs are output B



A

B

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY