PROBLEM SYMPTOMS TABLE
Troubleshooting · Vehicles built Jun 2006 – Sep 2006
Versions by build date: Jun 2006 – Sep 2006 Oct 2006 – May 2009 from Jun 2009
| Symptom |
Suspected Area |
See page |
| All functions of the A/C system do not operate |
1. IG power source circuit |
Click here
|
| 2. Back-up power source circuit |
Click here
|
|
| 3. Heater control panel power source circuit |
Click here
|
|
| 4. LIN communication circuit |
Click here
|
|
| 5. A/C control assembly |
Click here
|
|
| 6. A/C amplifier |
Click here
|
|
| Air Flow Control: No blower operation |
1. Blower motor circuit |
Click here
|
| 2. Heater control panel power source circuit |
Click here
|
|
| 3. LIN communication circuit |
Click here
|
|
| 4. A/C control assembly |
Click here
|
|
| 5. A/C amplifier |
Click here
|
|
| Air Flow Control: No blower control |
1. Blower motor circuit |
Click here
|
| 2. Heater control panel power source circuit |
Click here
|
|
| 3. LIN communication circuit |
Click here
|
|
| 4. A/C control assembly |
Click here
|
|
| 5. A/C amplifier |
Click here
|
|
| Air Flow Control: Insufficient air flow |
1. Blower motor circuit |
Click here
|
| 2. A/C amplifier |
Click here
|
|
| Temperature Control: No cool air comes out |
1. Refrigerant volume |
Click here
|
| 2. Refrigerant pressure |
Click here
|
|
| 3. Pressure switch circuit |
Click here
|
|
| 4. Compressor solenoid circuit |
Click here
|
|
| 5. Air mix control servo motor circuit |
Click here
|
|
| 6. Evaporator temperature sensor circuit |
Click here
|
|
| 7. Ambient temperature sensor circuit |
Click here
|
|
| 8. Heater control panel power source circuit |
Click here
|
|
| 9. LIN communication circuit |
Click here
|
|
| 10. Expansion valve |
Click here
|
|
| 11. A/C control assembly |
Click here
|
|
| 12. A/C amplifier |
Click here
|
|
| 13. ECM |
Click here
|
|
| Temperature Control: No warm air comes out |
1. Air mix control servo motor circuit |
Click here
|
| 2. Evaporator temperature sensor circuit |
Click here
|
|
| 3. Ambient temperature sensor circuit |
Click here
|
|
| 4. A/C amplifier |
Click here
|
|
| Temperature Control: Output air is warmer or cooler than the set temperature or response is slow. |
1. Refrigerant volume |
Click here
|
| 2. Refrigerant pressure |
Click here
|
|
| 3. Ambient temperature sensor circuit |
Click here
|
|
| 4. Air mix control servo motor circuit |
Click here
|
|
| 5. Radiator unit sub-assembly |
Click here
|
|
| 6. Expansion valve |
Click here
|
|
| 7. A/C amplifier |
Click here
|
|
| Temperature control: No temperature control (only Max. cool or Max. warm) |
1. Air mix control servo motor circuit |
Click here
|
| 2. Ambient temperature sensor circuit |
Click here
|
|
| 3. Evaporator temperature sensor circuit |
Click here
|
|
| 4. A/C control assembly |
Click here
|
|
| 5. A/C amplifier |
Click here
|
|
| No air inlet control |
1. Air inlet control servo motor circuit |
Click here
|
| 2. A/C amplifier |
Click here
|
|
| No air flow mode control |
1. Air outlet control servo motor circuit |
Click here
|
| 2. A/C amplifier |
Click here
|
|
| Engine idle up does not occur, or is continuous |
1. Compressor solenoid circuit |
Click here
|
| 2. Heater control panel power source circuit |
Click here
|
|
| 3. LIN communication circuit |
Click here
|
|
| 4. A/C control assembly |
Click here
|
|
| 5. A/C amplifier |
Click here
|
|
| 6. ECM |
Click here
|
|
| Diagnostic trouble codes are not recorded. Set mode is cleared when ignition switch is turned off. |
1. Back-up power source circuit |
Click here
|
| 2. A/C amplifier |
Click here
|
| Symptom |
Suspected Area |
See page |
| All functions of the A/C system do not operate |
1. IG power source circuit |
Click here
|
| 2. Back-up power source circuit |
Click here
|
|
| 3. Heater control panel power source circuit |
Click here
|
|
| 4. LIN communication circuit |
Click here
|
|
| 5. A/C control assembly |
Click here
|
|
| 6. A/C amplifier |
Click here
|
|
| Air Flow Control: No blower operation |
1. Blower motor circuit |
Click here
|
| 2. Heater control panel power source circuit |
Click here
|
|
| 3. LIN communication circuit |
Click here
|
|
| 4. A/C control assembly |
Click here
|
|
| 5. A/C amplifier |
Click here
|
|
| Air Flow Control: No blower control |
1. Blower motor circuit |
Click here
|
| 2. Heater control panel power source circuit |
Click here
|
|
| 3. LIN communication circuit |
Click here
|
|
| 4. A/C control assembly |
Click here
|
|
| 5. A/C amplifier |
Click here
|
|
| Air Flow Control: Insufficient air flow |
1. Blower motor circuit |
Click here
|
| 2. A/C amplifier |
Click here
|
|
| Temperature Control: No cool air comes out |
1. Refrigerant volume |
Click here
|
| 2. Refrigerant pressure |
Click here
|
|
| 3. Pressure switch circuit |
Click here
|
|
| 4. Compressor solenoid circuit |
Click here
|
|
| 5. Air mix control servo motor circuit (Driver side) |
Click here
|
|
| 6. Air mix control servo motor circuit (Passenger side) |
Click here
|
|
| 7. Evaporator temperature sensor circuit |
Click here
|
|
| 8. Room temperature sensor circuit |
Click here
|
|
| 9. Ambient temperature sensor circuit |
Click here
|
|
| 10. Heater control panel power source circuit |
Click here
|
|
| 11. LIN communication circuit |
Click here
|
|
| 12. Expansion valve |
Click here
|
|
| 13. A/C control assembly |
Click here
|
|
| 14. A/C amplifier |
Click here
|
|
| 15. ECM |
Click here
|
|
| Temperature Control: No warm air comes out |
1. Air mix control servo motor circuit (Driver side) |
Click here
|
| 2. Air mix control servo motor circuit (Passenger side) |
Click here
|
|
| 3. Evaporator temperature sensor circuit |
Click here
|
|
| 4. Room temperature sensor circuit |
Click here
|
|
| 5. Ambient temperature sensor circuit |
Click here
|
|
| 6. A/C amplifier |
Click here
|
|
| Temperature Control: Output air is warmer or cooler than the set temperature or response is slow. |
1. Refrigerant volume |
Click here
|
| 2. Refrigerant pressure |
Click here
|
|
| 3. Solar sensor circuit (Driver side) |
Click here
|
|
| 4. Solar sensor circuit (Passenger side) |
Click here
|
|
| 5. Room temperature sensor circuit |
Click here
|
|
| 6. Ambient temperature sensor circuit |
Click here
|
|
| 7. Air mix control servo motor circuit (Driver side) |
Click here
|
|
| 8. Air mix control servo motor circuit (Passenger side) |
Click here
|
|
| 9. Radiator unit sub-assembly |
Click here
|
|
| 10. Expansion valve |
Click here
|
|
| 11. A/C amplifier |
Click here
|
|
| Temperature control: No temperature control (only Max. cool or Max. warm) |
1. Air mix control servo motor circuit (Driver side) |
Click here
|
| 2. Air mix control servo motor circuit (Passenger side) |
Click here
|
|
| 3. Room temperature sensor circuit |
Click here
|
|
| 4. Ambient temperature sensor circuit |
Click here
|
|
| 5. Evaporator temperature sensor circuit |
Click here
|
|
| 6. Solar sensor circuit (Driver side) |
Click here
|
|
| 7. Solar sensor circuit (Passenger side) |
Click here
|
|
| 8. A/C control assembly |
Click here
|
|
| 9. A/C amplifier |
Click here
|
|
| No air inlet control |
1. Air inlet control servo motor circuit |
Click here
|
| 2. A/C amplifier |
Click here
|
|
| No air flow mode control |
1. Air outlet control servo motor circuit |
Click here
|
| 2. A/C amplifier |
Click here
|
|
| Engine idle up does not occur, or is continuous |
1. Compressor solenoid circuit |
Click here
|
| 2. Heater control panel power source circuit |
Click here
|
|
| 3. LIN communication circuit |
Click here
|
|
| 4. A/C control assembly |
Click here
|
|
| 5. A/C amplifier |
Click here
|
|
| 6. ECM |
Click here
|
|
| Blinking of A/C indicator |
1. Compressor solenoid circuit |
Click here
|
| 2. A/C amplifier |
Click here
|
|
| Diagnostic trouble codes are not recorded. Set mode is cleared when ignition switch is turned off. |
1. Back-up power source circuit |
Click here
|
| 2. A/C amplifier |
Click here
|