This circuit opens and closes the intake air control valve assembly (built into intake air surge tank assembly) in response to changes in the engine load in order to increase the intake efficiency using the acoustic control induction system.
When the engine speed is between 0 and 4200 rpm and the throttle valve opening angle is 60° or more, the ECM supplies current to the actuator (on status), to close the intake air control valve assembly. Under other conditions, the intake air control valve assembly is open.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P0660 | Intake Manifold Tuning Valve Control Circuit / Open (Bank 1) | The following conditions are met simultaneously for 0.5 seconds or more (2 trip detection logic):
·
Voltage of terminal acoustic control induction system of the ECM is low when the actuator is off ·
The engine has been started |
·
Open or short in intake air control valve assembly circuit ·
Intake air surge tank assembly (intake air control valve assembly) ·
No. 1 integration relay ·
ECM |
Comes on | DTC stored |
Inspect the fuses for circuits related to this system before performing the following procedure.
Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine / Active Test / Activate the VSV for Intake Control.
| Tester Display |
|---|
| Activate the VSV for Intake Control |
Check if operating noise can be heard when operating the intake air control valve assembly using the tester.
Operating noise can be heard.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the intake air surge tank assembly (intake air control valve assembly).
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Intake Air Control Valve Assembly) |
Disconnect the intake air control valve assembly connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E46-2 - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the intake air control valve assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E46-1 - E26-47 (ACIS) | Always | Below 1 Ω |
| E46-1 or E26-47 (ACIS) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the intake air control valve assembly connector.
Remove the No. 1 integration relay from the engine room relay block and junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E46-2 - 1A-8 | Always | Below 1 Ω |
| E46-2 or 1A-8 - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG