The power management control ECU monitors the battery smart unit and detects insulation malfunctions in the high-voltage system.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0AA6-526 | Hybrid Battery Voltage System Isolation Fault | Insulation resistance between the high-voltage circuit and the body has decreased.*1*2 | ·
Hybrid vehicle transaxle assembly ·
Inverter with converter assembly ·
No. 4 floor wire ·
No. 4 engine wire ·
Hybrid battery junction block assembly ·
Air conditioning system ·
HV battery ·
Battery smart unit |
Does not come on | Master Warning Light:
Comes on |
| P0AA6-611 | Hybrid Battery Voltage System Isolation Fault | Insulation resistance of the high voltage circuit in the air conditioning system has decreased.*3 | Air conditioning system | Does not come on | Master Warning Light:
Comes on |
| P0AA6-612 | Hybrid Battery Voltage System Isolation Fault | Insulation resistance of the HV battery area has decreased.*3 | ·
Hybrid battery junction block assembly ·
Battery smart unit ·
HV battery |
Does not come on | Master Warning Light:
Comes on |
| P0AA6-613 | Hybrid Battery Voltage System Isolation Fault | Insulation resistance of the transaxle area has decreased.*3 | ·
Hybrid vehicle transaxle assembly ·
Inverter with converter assembly |
Does not come on | Master Warning Light:
Comes on |
| P0AA6-614 | Hybrid Battery Voltage System Isolation Fault | Insulation resistance of the high-voltage DC area has decreased.*3 | ·
Inverter with converter assembly ·
No. 4 floor wire ·
Air conditioning system ·
No. 4 engine wire ·
Hybrid battery junction block assembly |
Does not come on | Master Warning Light:
Comes on |
*1: INF code 526 is stored together with P0AA6.
*2: The insulation malfunction detection circuit in the battery smart unit monitors the insulation resistance between the high voltage circuits and body. If the insulation resistance decreases, the power management control ECU stores DTC P0AA6-526 and illuminates the MIL first.
*3: If the following operations are performed within the same trip after DTC P0AA6-526 is stored, just one of the related DTCs (P0AA6-611, 612, 613 or 614) will be stored.
Apply the parking brake firmly.
Wait for 1 minute or more with the vehicle stopped, the brake pedal firmly depressed, the power switch on (READY), the shift lever in D and the air conditioning system on (Lo/COOL MAX, blower speed HI), then turn the power switch off and wait for 1 minute or more.
If DTC P0AA6 is stored, the vehicle cannot start.
When measuring insulation resistance using a megohmmeter, measure the resistance while jiggling the high voltage wire harness.
| *1 | HV Battery | *2 | Battery Smart Unit |
| *3 | SMRB | *4 | SMRG |
| *5 | SMRP | *6 | System Main Resistor |
| *7 | Service Plug Grip | *8 | Inverter with Converter Assembly |
| *9 | Boost Converter | *10 | Inverter |
| *11 | MG1 | *12 | MG2 |
| *13 | Compressor with Motor Assembly | *14 | A/C Inverter |
| *15 | A/C Motor | - | - |
| *a | High-voltage Areas | *b | INF Code 526 Vehicle Insulation Resistance Reduction Area |
| *c | INF Code 611 Air Conditioning System Area | *d | INF Code 612 HV Battery Area |
| *e | INF Code 613 Transaxle Area | *f | INF Code 614 High Voltage Direct Current Area |
If a decrease in insulation resistance cannot be confirmed using a megohmmeter, check the Short Wave Highest Val in the Data List.
Characteristics of Short Wave Highest Value
The Data List item Short Wave Highest Val and insulation resistance have the relationship shown in the table below. Short Wave Highest Val decreases with a decrease in insulation resistance. However, in some cases, even though the insulation resistance of the vehicle is normal, Short Wave Highest Val may decrease. Therefore, check Short Wave Highest Val while considering the following.
Do not check until approximately 1 minute has passed after the power switch is turned on (IG) (*1).
Do not check when there is a difference between the system voltages (Power Resource VB, VL-Voltage before Boosting, and VH-Voltage after Boosting) (*2).
| Short Wave Highest Value | Trouble Area |
|---|---|
| Neither condition (*1) nor (*2) is met and Short Wave Highest Val is approximately 0 V | Since the insulation resistance is close to 0 Ω, there is a strong possibility of interference with a metal object. |
| Neither condition (*1) nor (*2) is met and Short Wave Highest Val is between 0 and 5 V | Since the insulation resistance is several hundred kilo ohms, there is a strong possibility of the presence of fluid such as coolant. |
How to Determine Part with Insulation Malfunction
Jiggle the high-voltage wire harness to check if the resistance to body ground changes with the position of the wire harness or force applied.
Repeat rotating and stopping of the MG1, MG2 and compressor with motor assembly. Check that the Short Wave Highest Val does not decrease (for example if the motor stops with foreign matter forming a leak path) when the motor stops, or that the Short Wave Highest Val does not return to normal (for example if foreign matter moves away from the leak path) when the motor rotates.
Increase the temperature of MG1and MG2. Check if the Short Wave Highest Val decreases with the temperature increase.
Check that the transaxle fluid is not cloudy and the coolant level in the reserve tank has not dropped as the transaxle fluid will become cloudy when mixed with coolant, resulting in low insulation resistance.
When performing P0AA6 troubleshooting, use either a tool wrapped with vinyl insulation tape or a insulated tool. (It is extremely dangerous when a high-voltage charge passes through a non-insulated tool causing a short.)
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
When measuring insulation resistance using a megohmmeter, set the megohmmeter to 500 V.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P0AA6 only is output. | A |
| P0AA6 and P0A1D (power management control ECU malfunction) are output. | B |
| P0AA6 and P0AA7 (malfunction in the battery smart unit) are output. | C |
| P0AA6 and P0AFC (Hybrid Battery Pack Sensor Module) are output. | D |
Turn the power switch off.
A
B
(Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
C
D
(Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Access the freeze frame data of DTC P0AA6 and read the INF code.
Information codes 611, 612, 613 and 614 are not stored with 526 simultaneously. If a drop in insulation resistance is detected and DTC P0AA6-526 is output, turn the power switch on (READY) and wait for 1 minute with the shift lever in D and the air conditioning system on, then turn the power switch off and wait for 1 minute to determine on of the information code (611, 612, 613 or 614).
If only DTC P0AA6-526 is output, perform the diagnosis procedure for INF code 526 to inspect all the high voltage circuits.
Turn the power switch off.
A
B
C
D
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.
Make sure that no foreign objects have entered or contaminated the inverter with converter assembly.
| *1 | Generator Cable |
| *2 | Motor Cable |
Disconnect the motor cable and generator cable from the inverter with converter assembly.
| *1 | Shield Ground |
| *a | Motor Cable
(Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| n1-3 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| n1-2 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| n1-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *1 | Shield Ground |
| *a | Generator Cable
(Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| o1-3 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| o1-2 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| o1-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the connector cover assembly from the inverter with converter assembly.
Make sure that no foreign objects have entered or contaminated the inverter with converter assembly.
Disconnect connector G2 of the No. 4 engine wire (air conditioning harness) from the inverter with converter assembly.
Make sure that no foreign objects have entered or contaminated connector G2 of the No. 4 engine wire (air conditioning harness).
| *1 | Shield Ground |
| *a | No. 4 Engine Wire (Air Conditioning Harness)
(Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G2-1 (ACPE) - Body ground and shield ground | Power switch off | 3 MΩ or higher |
| G2-2 (ACPB) - Body ground and shield ground | Power switch off | 3 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector Q1 of the No. 4 floor wire from the inverter with converter assembly.
Make sure that no foreign objects have entered or contaminated connector Q1 of the No. 4 floor wire.
| *1 | High Voltage Fuse |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| High voltage fuse terminal - Body ground | Power switch off | 1 MΩ or higher |
Perform this inspection with the motor cable, generator cable and No. 4 engine wire (air conditioning harness) disconnected from the inverter with converter assembly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *1 | Shield Ground |
| *a | No. 4 Floor Wire
(Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| Q1-1 (CBI) - Body ground and shield ground | Power switch off | 10 MΩ or higher |
| Q1-2 (CEI) - Body ground and shield ground | Power switch off | 10 MΩ or higher |
Visually inspect the No. 4 floor wire for damage. If there is any damage, then this is the likely cause of low insulation resistance.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 2 hybrid vehicle battery shield panel.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL
Disconnect connector z7 from the battery smart unit.
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 1 - Body ground | Power switch off | 10 MΩ or higher |
| 2 - Body ground | Power switch off | 10 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 4 hybrid battery shield panel.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>REMOVAL
Disconnect connector Q2 and connector Q3 of the No. 4 floor wire from the hybrid battery junction block assembly.
Make sure that no foreign objects have entered or contaminated connector Q2 and Q3 of the No. 4 floor wire.
| *1 | Shield Ground |
| *a | No. 4 Floor Wire
(Hybrid Battery Junction Bock Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| Q3-1 (CEI) - Body ground and shield ground | Power switch off | 10 MΩ or higher |
| Q2-1 (CBI) - Body ground and shield ground | Power switch off | 10 MΩ or higher |
Visually inspect the No. 4 floor wire for damage. If there is any damage, then this is the likely cause of low insulation resistance.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the hybrid battery junction block assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV RELAY ASSEMBLY>COMPONENTS
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 1 - Body ground | Power switch off | 10 MΩ or higher |
| 2 - Body ground | Power switch off | 10 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper inverter cover (generator cable side) and upper inverter cover (motor cable side) from the inverter with converter assembly.
Make sure that no foreign objects have entered or contaminated the inverter with converter assembly.
| *1 | Generator Cable |
| *2 | Motor Cable |
Disconnect the motor cable and generator cable from the inverter with converter assembly.
Remove the connector cover assembly from the inverter with converter assembly.
Make sure that no foreign objects have entered or contaminated the inverter with converter assembly.
| *1 | High Voltage Fuse |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| High voltage fuse terminal - Body ground | Power switch off | 1 MΩ or higher |
| Result | Proceed to |
|---|---|
| NG | A |
| OK | B |
A
B
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
| *1 | Green Lock |
Disconnect connector G1 of the No. 4 engine wire (air conditioning harness) from the compressor with motor assembly.
| *1 | Shield Ground |
| *a | No. 4 Engine Wire (Air Conditioning Harness)
(Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G2-1 (ACPE) - Body ground and shield ground | Power switch off | 10 MΩ or higher |
| G2-2 (ACPB) - Body ground and shield ground | Power switch off | 10 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the connector cover assembly from the inverter with converter assembly.
Make sure that no foreign objects have entered or contaminated the inverter with converter assembly.
Disconnect connector Q1 of the No. 4 floor wire from the inverter with converter assembly.
Make sure that no foreign objects have entered or contaminated connector Q1 of the No. 4 floor wire.
| *1 | Shield Ground |
| *a | No. 4 Floor Wire
(Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| Q1-1 (CBI) - Body ground and shield ground | Power switch off | 10 MΩ or higher |
| Q1-2 (CEI) - Body ground and shield ground | Power switch off | 10 MΩ or higher |
Visually inspect the No. 4 floor wire for damage. If there is any damage, then this is the likely cause of low insulation resistance.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector G2 of the No. 4 engine wire (air conditioning harness) from the inverter with converter assembly.
| *1 | Shield Ground |
| *a | No. 4 Engine Wire (Air Conditioning Harness)
(Inverter with Converter Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G2-1 (ACPE) - Body ground and shield ground | Power switch off | 3 MΩ or higher |
| G2-2 (ACPB) - Body ground and shield ground | Power switch off | 3 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG