1. PRECAUTION
G3834
2.REMOVE SERVICE PLUG GRIP
3.DRAIN COOLANT (for Inverter)
4.REMOVE CONNECTOR COVER ASSEMBLY
Do not touch the high voltage connectors and terminals for 10 minutes after the service plug grip is removed.
Wear insulated gloves.
Do not start the hybrid system with the service plug grip removed because it may cause a malfunction.
Remove the 2 bolts and connector cover assembly.
Make sure to pull the connector cover assembly straight up, as a connector is connected to the bottom of the cover.
Do not allow any foreign objects or water to enter the inverter with converter assembly.
5.CHECK TERMINAL VOLTAGE
Wear insulated gloves.
Do not allow any foreign objects or water to enter the inverter with converter assembly.
Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors.
0 V
Use a measuring range of DC 750 V or more on the voltmeter.
6.TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY
Wear insulated gloves.
Temporarily install the connector cover assembly with the bolt to prevent any foreign objects or water from entering the inverter with converter assembly.
53295E
7.REMOVE COOL AIR INTAKE DUCT SEAL
17750A
8.REMOVE INLET AIR CLEANER ASSEMBLY
17735
9.REMOVE AIR CLEANER CAP SUB-ASSEMBLY
17801
10.REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
11.REMOVE AIR CLEANER CASE SUB-ASSEMBLY
G9257
12.REMOVE NO. 5 INVERTER BRACKET
Remove the 2 bolts and No. 5 inverter bracket.
G9217
13.REMOVE NO. 4 INVERTER BRACKET
Remove the 3 bolts and No. 4 inverter bracket.
G9221B
14.REMOVE UPPER INVERTER COVER
Wear insulated gloves.
Remove the 2 bolts and upper inverter cover (generator cable side).
Make sure to pull the upper inverter cover straight up, as a connector is connected to the bottom of the cover.
Do not touch the upper inverter cover waterproofing rubber.
G2148
15.DISCONNECT GENERATOR CABLE
Wear insulated gloves.
Using an insulated tool, remove the 3 bolts.
Disconnect the 2 wire harness clamps and separate the generator cable.
Do not damage the terminals, connector housings or inverter with converter assembly when disconnecting them.
Do not touch the connector waterproofing rubber or terminals.
Insulate the removed terminals with insulating tape.
Do not allow any foreign objects or water to enter the inverter with converter assembly.
G9221B
16.REMOVE UPPER INVERTER COVER
Wear insulated gloves.
Remove the 2 bolts and upper inverter cover (motor cable side).
Make sure to pull the upper inverter cover straight up, as a connector is connected to the bottom of the cover.
Do not touch the upper inverter cover waterproofing rubber.
G1148
17.DISCONNECT MOTOR CABLE
Wear insulated gloves.
Using an insulated tool, remove the 3 bolts.
Disconnect the 3 wire harness clamps and separate the motor cable.
Do not damage the terminals, connector housings or inverter with converter assembly when disconnecting them.
Do not touch the connector waterproofing rubber or terminals.
Insulate the removed terminals with insulating tape.
Do not allow any foreign objects or water to enter the inverter with converter assembly.
G1143C
18.REMOVE NO. 3 MOTOR CABLE BRACKET
Disconnect the hose clamp from the No. 3 motor cable bracket.
Do not remove the hose clamp from the hose.
Remove the 2 bolts and No. 3 motor cable bracket.
19.REMOVE CONNECTOR COVER ASSEMBLY
Wear insulated gloves.
Remove the bolt and connector cover assembly.
Make sure to pull the connector cover assembly straight up, as a connector is connected to the bottom of the cover.
Do not allow any foreign objects or water to enter the inverter with converter assembly.
82124
20.DISCONNECT NO. 4 ENGINE WIRE
Wear insulated gloves.
Disconnect the No. 4 engine wire.
Do not damage the terminals, connector housings or inverter with converter assembly when disconnecting them.
Do not touch the connector waterproofing rubber or terminals.
Insulate the removed terminals with insulating tape.
Do not allow any foreign objects or water to enter the inverter with converter assembly.
Disconnect the wire harness clamp.
82164C
21.DISCONNECT NO. 4 FLOOR WIRE
Remove the bolt.
Disconnect the wire harness clamp and connector.
Do not damage the terminals, connector housings or inverter with converter assembly when disconnecting them.
Do not touch the connector waterproofing rubber or terminals.
Insulate the removed terminals with insulating tape.
Do not allow any foreign objects or water to enter the inverter with converter assembly.
22.TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY
Wear insulated gloves.
Temporarily install the connector cover assembly with the bolt to prevent any foreign objects or water from entering the inverter with converter assembly.
23.DISCONNECT LOW VOLTAGE CONNECTOR
Insulate the removed terminals with insulating tape.
Do not allow any foreign objects or water to enter the inverter with converter assembly.
Raise the lock lever and disconnect the 3 low voltage connectors.
82113
24.DISCONNECT NO. 3 ENGINE ROOM WIRE
Remove the relay block cover.
Remove the nut.
Disconnect the wire harness clamp and No. 3 engine room wire.
G9228A
25.REMOVE NO. 4 INVERTER COOLING HOSE
| *1 | Retainer |
Release the retainer and disconnect the No. 4 inverter cooling hose from the inverter with converter assembly.
Put pieces of cloth into the pipes and in the disconnected hoses, or cover the pipes and hoses with plastic bags as shown in the illustration to prevent foreign matter from entering the cooling system and to prevent coolant from spilling near the inverter with converter assembly.
G90A0A
26.REMOVE NO. 1 INVERTER COOLING HOSE ASSEMBLY
| *1 | Retainer |
Release the retainer and disconnect the No. 1 inverter cooling hose from the inverter with converter assembly.
Put pieces of cloth into the pipes and in the disconnected hoses, or cover the pipes and hoses with plastic bags as shown in the illustration to prevent foreign matter from entering the cooling system and to prevent coolant from spilling near the inverter with converter assembly.
G9200
27.REMOVE INVERTER WITH CONVERTER ASSEMBLY
Wear insulated gloves.
| *1 | No. 3 Engine Room Wire |
| *2 | Hook |
Temporarily secure the No. 3 engine room wire with the inverter with converter assembly hook as shown in the illustration.
Remove the 2 bolts, nut and inverter with converter assembly.
Since the inverter with converter assembly is very heavy, 2 people are needed to remove the inverter with converter assembly. When removing the inverter with converter assembly, do not damage the parts around it.
To prevent damage, do not hold the inverter with converter assembly by the connectors.
To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.
Even after the coolant is drained, coolant remains in the inverter with converter assembly due to its internal structure. Therefore, seal or cover the pipes when removing the inverter with converter to prevent coolant from spilling out or foreign matter from entering the inverter with converter.
28.REMOVE HIGH VOLTAGE FUSE
Wear insulated gloves.
Perform this procedure only when replacement of the high voltage fuse is necessary.
Remove the bolt and connector cover assembly.
Make sure to pull the connector cover assembly straight up, as a connector is connected to the bottom of the cover.
Do not allow any foreign objects or water to enter the inverter with converter assembly.
Remove the 2 nuts and high voltage fuse.
Temporarily install the connector cover assembly with the bolt to prevent any foreign objects or water from entering the inverter with converter assembly.
17771A
29.REMOVE AIR CLEANER BRACKET
Remove the bolt and air cleaner bracket.
17119A
30.REMOVE AIR CLEANER BRACKET
Remove the bolt and air cleaner bracket.
G9214
31.REMOVE NO. 1 INVERTER BRACKET
Remove the 2 bolts and No. 1 inverter bracket.
G9215
32.REMOVE NO. 2 INVERTER BRACKET
Remove the 2 bolts and No. 2 inverter bracket.
G9216
33.REMOVE NO. 3 INVERTER BRACKET
Remove the 2 bolts and No. 3 inverter bracket.
G1143A
34.REMOVE NO. 1 MOTOR CABLE BRACKET
Remove the 2 bolts and No. 1 motor cable bracket.
G1143B
35.REMOVE NO. 2 MOTOR CABLE BRACKET
Remove the 2 bolts and No. 2 motor cable bracket.
G9225J
36.REMOVE NO. 1 INVERTER COOLING HOSE
| *1 | Retainer |
Release the retainer and disconnect the No. 1 inverter cooling hose from the inverter with converter assembly.
Remove the No. 1 inverter cooling hose.
Put pieces of cloth into the pipes and in the disconnected hoses, or cover the pipes and hoses with plastic bags as shown in the illustration to prevent foreign matter from entering the cooling system and to prevent coolant from spilling near the inverter with converter assembly.
82113
37.REMOVE NO. 3 ENGINE ROOM WIRE
Open the cover.
Do not twist the cover excessively when opening it.
Remove the nut and No. 3 engine room wire.