Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)
RM33C0E _51 Engine / Hybrid System _065433 HYBRID / BATTERY CONTROL _0331295 HYBRID CONTROL SYSTEM(for NICKEL METAL HYDRIDE BATTERY) C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM(for NICKEL METAL HYDRIDE BATTERY)  P1C8549  High Voltage Power Resource Internal Electronic Failure  


DESCRIPTION

The hybrid vehicle control ECU assembly monitors the system internal operation, it will store a DTC and perform fail-safe control if it detects the following malfunction.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P1C8549 High Voltage Power Resource Internal Electronic Failure Battery overcurrent or overload current occurs due to a malfunction in the high-voltage circuit between the hybrid system, battery and inverter.
(1 trip detection logic)
·

Hybrid vehicle control ECU assembly

·

HV battery junction block assembly

·

Battery voltage sensor

·

Hybrid battery thermistor (wire harness or connector)

·

Wire harness or connector


Does not come on Master Warning Light:
Comes on

Related Data List
DTC No. Data List
P1C8549
·

Hybrid Battery Current

·

Hybrid Battery Voltage

·

VL-Voltage before Boosting

·

VH-Voltage after Boosting



CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Drive the vehicle for approximately 10 minutes according to the freeze frame data items "Vehicle Speed", "Accelerator Position" and "Hybrid Battery Current".

7.

Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C44
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT (HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.


d.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Result:
Result Proceed to
P1C8549 only is output. A
DTCs other than P1C8549 is also output. B



e.

Turn the power switch off.



A

2.CHECK BATTERY VOLTAGE SENSOR (IGCT VOLTAGE)

B

2.CHECK BATTERY VOLTAGE SENSOR (IGCT VOLTAGE)

OK

3.CHECK HARNESS AND CONNECTOR (BATTERY VOLTAGE SENSOR - HV BATTERY JUNCTION BLOCK ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY VOLTAGE SENSOR POWER SOURCE CIRCUIT)

3.CHECK HARNESS AND CONNECTOR (BATTERY VOLTAGE SENSOR - HV BATTERY JUNCTION BLOCK ASSEMBLY)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.




c.
A406235N01
1.167,1.333 1.583,1.625 0.417,0.292 1.219,1.375 1.542,1.583 0.323,0.208 10 true z18

Disconnect the z18 battery current sensor connector.

NOTICE:

Before disconnecting the connector, check that it is not loose or disconnected.




e.

Disconnect the z17 battery voltage sensor connector.

NOTICE:

Before disconnecting the connector, check that it is not loose or disconnected.



f.
A368052C03
2.198,2.094 2.625,2.354 0.427,0.26 2.063,3.552 2.49,3.813 0.427,0.26 1.198,1.781 1.583,2.281 true 1.771,4.031 2.365,4.208 true 0.844,2.458 1.49,2.396 true 0.865,2.094 1.5,2.271 true 0.844,4.208 1.469,4.052 true 0.854,3.583 1.448,3.76 true 0.229,0.073 0.677,0.552 0.448,0.479 10 false *a 0.344,3.01 0.917,3.542 0.573,0.531 10 false *b 2.344,2.125 2.792,2.604 0.448,0.479 10 false z17 2.156,3.594 2.604,4.073 0.448,0.479 10 false z18 0.969,1.688 1.542,2.219 0.573,0.531 10 false IB0 2.406,4.135 2.917,4.458 0.51,0.323 10 false IB0 0.615,2.385 1.188,2.917 0.573,0.531 10 false GIB 0.635,1.99 1.208,2.521 0.573,0.531 10 false VIB 0.583,4.146 1.156,4.531 0.573,0.385 10 false GIB 0.594,3.469 1.167,4 0.573,0.531 10 false VIB
*a Rear view of wire harness connector
(to Battery Voltage Sensor)
*b Front view of wire harness connector
(to HV Battery Junction Block Assembly (Battery Current Sensor))


Measure the resistance according to the value(s) in the tables below.

Standard Resistance (Check for Open):
Tester Connection Condition Specified Condition
z17-5 (IB0) - z18-4 (IB0) Power switch off Below 1 Ω
z17-12 (GIB) - z18-3 (GIB) Power switch off Below 1 Ω
z17-6 (VIB) - z18-1 (VIB) Power switch off Below 1 Ω


Standard Resistance (Check for Short):
Tester Connection Condition Specified Condition
z17-5 (IB0) or z18-4 (IB0) - Body ground and other terminals Power switch off 10 kΩ or higher
z17-12 (GIB) or z18-3 (GIB) - Body ground and other terminals Power switch off 10 kΩ or higher
z17-6 (VIB) or z18-1 (VIB) - Body ground and other terminals Power switch off 10 kΩ or higher


HINT:

As the battery harness is not available as a supply part, if the harness cannot be repaired, replace the HV battery.



g.

Reconnect the z17 battery voltage sensor connector.


h.

Install the No. 1 hybrid battery exhaust duct.


i.

Reconnect the z18 battery current sensor connector.


j.

Install the No. 1 HV battery cover panel RH.


Result:
Proceed to
OK
NG



OK

4.CHECK BATTERY VOLTAGE SENSOR (VIB VOLTAGE)

NG

4.CHECK BATTERY VOLTAGE SENSOR (VIB VOLTAGE)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.




c.

Connect the cable to the negative (-) auxiliary battery terminal.


d.

Turn the power switch on (IG).


e.
A368051C52
1.677,0.208 2.115,0.438 0.438,0.229 1.135,1.667 1.677,0.979 true 1.688,0.875 1.26,0.427 true 0.104,0.063 0.5,0.375 0.396,0.313 10 false *a 1.792,0.24 2.188,0.552 0.396,0.313 10 false z17 0.938,1.708 1.271,1.969 0.333,0.26 10 false GIB 0.958,0.344 1.292,0.604 0.333,0.26 10 false VIB
*a Component with harness connected
(Battery Voltage Sensor)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
z17-6 (VIB) - z17-12 (GIB) Power switch on (IG) 4.6 to 5.4 V


NOTICE:

Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.



f.

Turn the power switch off.


g.

Disconnect the cable from the negative (-) auxiliary battery terminal.


h.

Install the No. 1 hybrid battery exhaust duct.


Result:
Proceed to
OK
NG



OK

5.CHECK BATTERY VOLTAGE SENSOR (GIB - GND)

NG

7.CHECK BATTERY VOLTAGE SENSOR (VIB VOLTAGE)
5.CHECK BATTERY VOLTAGE SENSOR (GIB - GND)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.




c.

Disconnect the z17 and R21 battery voltage sensor connectors.

NOTICE:

Before disconnecting the connector, check that it is not loose or disconnected.



d.
A379234C07
1.646,0.313 2.042,0.521 0.396,0.208 2.177,0.313 2.583,0.542 0.406,0.229 1.156,0.438 1.708,0.958 true 2.865,0.438 2.479,0.958 true 0.073,0.083 0.469,0.333 0.396,0.25 10 false *a 0.906,0.354 1.385,0.677 0.479,0.323 10 false GIB 2.24,0.333 2.719,0.656 0.479,0.323 10 false R21 1.74,0.333 2.219,0.656 0.479,0.323 10 false z17 2.906,0.354 3.354,0.76 0.448,0.406 10 false GND
*a Component without harness connected
(Battery Voltage Sensor)


Measure the resistance according to the value(s) in the tables below.

Standard Resistance:
Tester Connection Condition Specified Condition
z17-12 (GIB) - R21-5 (GND) Power switch off Below 1 Ω



e.

Reconnect the z17 and R21 battery voltage sensor connectors.


f.

Install the No. 1 hybrid battery exhaust duct.


Result:
Proceed to
OK
NG



OK

6.CHECK HYBRID VEHICLE CONTROL ECU ASSEMBLY (HYBRID BATTERY CURRENT)

NG

6.CHECK HYBRID VEHICLE CONTROL ECU ASSEMBLY (HYBRID BATTERY CURRENT)
a.

Connect the Techstream to the DLC3.


b.

Turn the power switch on (IG).

NOTICE:

During the inspection, make sure to only turn the power switch on (IG). Do not turn the power switch on (READY).



c.

Enter the following menus: Powertrain / Hybrid Control / Data List / Hybrid/EV Battery Current, Hybrid/EV Battery Current for Hybrid/EV Battery Control.

Powertrain > Hybrid Control > Data List
Tester Display
Hybrid/EV Battery Current
Hybrid/EV Battery Current for Hybrid/EV Battery Control
50003 397 228,318

d.

With the power switch on (IG), monitor Data List item "Hybrid/EV Battery Current" and "Hybrid/EV Battery Current for Hybrid/EV Battery Control" for 1 minute.

Result:
Result Proceed to
The value of Data List item "Hybrid/EV Battery Current" and "Hybrid/EV Battery Current for Hybrid/EV Battery Control" is -0.5 A or less or 0.5 A or more. A
Other than above B



e.

Turn the power switch off.



A

B

REPLACE HYBRID VEHICLE CONTROL ECU ASSEMBLY

7.CHECK BATTERY VOLTAGE SENSOR (VIB VOLTAGE)
CAUTION:

Be sure to wear insulated gloves.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.




c.
A406235N01
1.167,1.333 1.583,1.625 0.417,0.292 1.219,1.375 1.542,1.583 0.323,0.208 10 true z18

Disconnect the z18 battery current sensor connector.

NOTICE:

Before disconnecting the connector, check that it is not loose or disconnected.




e.

Connect the cable to the negative (-) auxiliary battery terminal.


f.

Turn the power switch on (IG).


g.
A368051C55
1.635,0.177 2.073,0.406 0.438,0.229 1.135,1.667 1.677,0.979 true 1.677,0.875 1.094,0.292 true 0.104,0.063 0.5,0.375 0.396,0.313 10 false *a 1.74,0.188 2.135,0.5 0.396,0.313 10 false z17 0.99,1.688 1.323,1.948 0.333,0.26 10 false GIB 0.823,0.177 1.156,0.438 0.333,0.26 10 false VIB
*a Component with harness connected
(Battery Voltage Sensor)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
z17-6 (VIB) - z17-12 (GIB) Power switch on (IG) 4.6 to 5.4 V


NOTICE:

Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.



h.

Turn the power switch off.


i.

Disconnect the cable from the negative (-) auxiliary battery terminal.


j.

Install the No. 1 hybrid battery exhaust duct.


k.

Reconnect the z18 battery current sensor connector.


l.

Install the No. 1 HV battery cover panel RH.


Result:
Proceed to
OK
NG



OK

NG