2011-2016 FJ Cruiser · Service Manual ENGINE

P0617 Starter Relay Circuit High

Diagnostic trouble codes · Vehicles built Dec 2007 – Jul 2009

Versions by build date: Jul 2007 – Nov 2007 Dec 2007 – Jul 2009 Aug 2009 – Oct 2010 Nov 2010 – Jul 2012 from Aug 2012

DESCRIPTION

While the engine is being cranked, the battery voltage is applied to terminal STA of the ECM. If the ECM detects the Starter Control (STA) signal while the vehicle is being driven, it determines that there is a malfunction in the STA circuit. The ECM then illuminates the MIL and sets the DTC.
This monitor runs when the vehicle is driven at 20 km/h (12.4 mph) for over 20 seconds.
DTC No.
DTC Detection Conditions
Trouble Areas
P0617
When conditions (a), (b) and (c) met for 20 seconds (1 trip detection logic)
  1. (a) Vehicle speed more than 20 km/h (12.4 mph)
  2. (b) Engine speed more than 1,000 rpm
  3. (c) STA signal ON
  1. Park/Neutral Position (PNP) switch (A/T*)
  2. STA relay circuit
  3. Ignition switch
  4. ECM
*: A/T denotes Automatic Transmission models and M/T denotes Manual Transmission models.

WIRING DIAGRAM

A172865E01
A133424E01

INSPECTION PROCEDURE

HINT:
  1. The following troubleshooting flowchart is based on the premise that the engine is cranked normally. If the engine will not crank, proceed to the problem symptoms table (Click here).
  2. Read freeze frame data using an intelligent tester. Freeze frame data record the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data, from the time the malfunction occurred.


1. READ VALUE USING INTELLIGENT TESTER (STARTER SIGNAL)
  1. Connect an intelligent tester to the DLC3.

  1. Turn the ignition switch ON.

  1. Turn the tester ON.

  1. Select the following menu items: Powertrain / Engine and ECT / Data List / Starter Signal.

  1. Check the value displayed on the tester when the ignition switch is turned to the ON and START positions.

    OK:
    Ignition Switch Positions
    Starter Signal
    ON
    OFF
    START
    ON

    Result:
    Result
    Proceed To
    OK
    A
    NG (A/T models)
    B
    NG (M/T models)
    C



B
Go to step 2

C
Go to step 8
A

CHECK FOR INTERMITTENT PROBLEMS (Click here)

2. READ VALUE USING INTELLIGENT TESTER (STARTER SIGNAL)

  1. C117645E67
    Disconnect the B35 Park/Neutral Position (PNP) connector.

  1. Connect an intelligent tester to the DLC3.

  1. Turn the ignition switch ON.

  1. Turn the tester ON.

  1. Select the following menu items: Powertrain / Engine and ECT / Data List / Starter Signal.

  1. Check the value displayed on the tester when the ignition switch is turned ON.

    Result:
    Starter Signal
    Proceed To
    Remains ON
    A
    OFF
    B

  1. Reconnect the PNP switch connector.



B
Go to step 4
A


3. INSPECT ECM (STA TERMINAL VOLTAGE)

  1. A172053E02
    Disconnect the B35 Park/Neutral Position (PNP) connector.

  1. Disconnect the B3 ECM connector.

  1. Turn the ignition switch ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connections
    Switch Conditions
    Specified Conditions
    Proceed To
    STA (B3-11) - Body ground
    Ignition switch ON
    11 to 14 V
    A
    Below 1.5 V
    B

  1. Reconnect the PNP switch connector.

  1. Reconnect the ECM connector.



B
REPLACE ECM (Click here)
A

REPAIR OR REPLACE HARNESS OR CONNECTOR (ECM - STA RELAY - PARK/NEUTRAL POSITION SWITCH)

4. INSPECT PARK/NEUTRAL POSITION SWITCH

  1. A093221E22
    Disconnect the B35 Park/Neutral Position (PNP) switch connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connections
    Switch Conditions
    Specified Conditions
    4 - 5
    Shift lever position except P and N
    10 kΩ or higher
    2 - 5
    All shift lever positions (P, R, N, D and S)
    10 kΩ or higher

    Result:
    Result
    Proceed To
    Short between 4 and 5
    A
    Short between 2 and 5
    B
    Within standard range
    C

  1. Reconnect the PNP switch connector.



B
REPLACE PARK/NEUTRAL POSITION SWITCH (Click here)

C
Go to step 6
A


5. REPLACE PARK/NEUTRAL POSITION SWITCH
  1. Replace the park/neutral position switch (Click here).


NEXT


6. INSPECT IGNITION SWITCH

  1. A116847E02
    Remove the ignition switch.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connections
    Switch Conditions
    Specified Conditions
    1 - 2, 1 - 7
    Ignition switch ON
    10 kΩ or higher

  1. Reinstall the ignition switch.



NG
REPLACE IGNITION SWITCH (Click here)
OK


7. INSPECT ECM (NSW TERMINAL VOLTAGE)

  1. A172054E02
    Disconnect the B2 ECM connector.

  1. Turn the ignition switch ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Resistance:
    Tester Connections
    Switch Conditions
    Specified Conditions
    Proceed To
    NSW (B2-8) - Body ground
    Ignition switch ON
    11 to 14 V
    A
    Below 1.5 V
    B

  1. Reconnect the ECM connector.



B
REPLACE ECM (Click here)
A

REPAIR OR REPLACE HARNESS OR CONNECTOR (IGNITION SWITCH - PARK/NEUTRAL POSITION SWITCH - ECM)

8. INSPECT IGNITION SWITCH

  1. A116847E02
    Remove the ignition switch.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connections
    Switch Conditions
    Specified Conditions
    1 - 2, 1 - 7
    Ignition switch ON
    10 kΩ or higher

  1. Reinstall the ignition switch.



NG
REPLACE IGNITION SWITCH (Click here)
OK


9. INSPECT ECM (STA TERMINAL VOLTAGE)

  1. A172053E02
    Disconnect the B3 ECM connector.

  1. Turn the ignition switch ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connections
    Switch Conditions
    Specified Conditions
    Proceed To
    STA (B3-11) - Body ground
    Ignition switch ON
    11 to 14 V
    A
    Below 1.5 V
    B

  1. Reconnect the ECM connector.



B
REPLACE ECM (Click here)
A

REPAIR OR REPLACE HARNESS OR CONNECTOR (IGNITION SWITCH - ECM - STA RELAY)


← P0617 Starter Relay Circuit High (Jul 2007 – Nov 2007)P0617 Starter Relay Circuit High (Aug 2009 – Oct 2010) →