P0617 Starter Relay Circuit High
Diagnostic trouble codes · Vehicles built Dec 2007 – Jul 2009
Versions by build date: Jul 2007 – Nov 2007 Dec 2007 – Jul 2009 Aug 2009 – Oct 2010 Nov 2010 – Jul 2012 from Aug 2012
DESCRIPTION
While the engine is being cranked, the battery voltage is applied to terminal STA of the ECM. If the ECM detects the Starter Control (STA) signal while the vehicle is being driven, it determines that there is a malfunction in the STA circuit. The ECM then illuminates the MIL and sets the DTC.This monitor runs when the vehicle is driven at 20 km/h (12.4 mph) for over 20 seconds.
| DTC No. |
DTC Detection Conditions |
Trouble Areas |
| P0617 |
When conditions (a), (b) and (c) met for 20 seconds (1 trip detection logic)
|
|
WIRING DIAGRAM




INSPECTION PROCEDURE
- HINT:
- The following troubleshooting flowchart is based on the premise that the engine is cranked normally. If the engine will not crank, proceed to the problem symptoms table (Click here).
- Read freeze frame data using an intelligent tester. Freeze frame data record the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data, from the time the malfunction occurred.
- The following troubleshooting flowchart is based on the premise that the engine is cranked normally. If the engine will not crank, proceed to the problem symptoms table (Click here).
| 1. READ VALUE USING INTELLIGENT TESTER (STARTER SIGNAL) |
Connect an intelligent tester to the DLC3.
Turn the ignition switch ON.
Turn the tester ON.
Select the following menu items: Powertrain / Engine and ECT / Data List / Starter Signal.
Check the value displayed on the tester when the ignition switch is turned to the ON and START positions.
- OK:
Ignition Switch Positions
Starter Signal
ON
OFF
START
ON
- Result:
Result
Proceed To
OK
A
NG (A/T models)
B
NG (M/T models)
C
|
|
||||
|
|
||||
| A | ||
| ||
| 2. READ VALUE USING INTELLIGENT TESTER (STARTER SIGNAL) |
Disconnect the B35 Park/Neutral Position (PNP) connector.

Connect an intelligent tester to the DLC3.
Turn the ignition switch ON.
Turn the tester ON.
Select the following menu items: Powertrain / Engine and ECT / Data List / Starter Signal.
Check the value displayed on the tester when the ignition switch is turned ON.
- Result:
Starter Signal
Proceed To
Remains ON
A
OFF
B
Reconnect the PNP switch connector.
|
|
||||
| A | |
| 3. INSPECT ECM (STA TERMINAL VOLTAGE) |
Disconnect the B35 Park/Neutral Position (PNP) connector.

Disconnect the B3 ECM connector.
Turn the ignition switch ON.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connections
Switch Conditions
Specified Conditions
Proceed To
STA (B3-11) - Body ground
Ignition switch ON
11 to 14 V
A
Below 1.5 V
B
Reconnect the PNP switch connector.
Reconnect the ECM connector.
|
|
||||
| A | ||
| ||
| 4. INSPECT PARK/NEUTRAL POSITION SWITCH |
Disconnect the B35 Park/Neutral Position (PNP) switch connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connections
Switch Conditions
Specified Conditions
4 - 5
Shift lever position except P and N
10 kΩ or higher
2 - 5
All shift lever positions (P, R, N, D and S)
10 kΩ or higher
- Result:
Result
Proceed To
Short between 4 and 5
A
Short between 2 and 5
B
Within standard range
C
Reconnect the PNP switch connector.
|
|
||||
|
|
||||
| A | |
| 5. REPLACE PARK/NEUTRAL POSITION SWITCH |
Replace the park/neutral position switch (Click here).
| NEXT | |
| 6. INSPECT IGNITION SWITCH |
Remove the ignition switch.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connections
Switch Conditions
Specified Conditions
1 - 2, 1 - 7
Ignition switch ON
10 kΩ or higher
Reinstall the ignition switch.
|
|
||||
| OK | |
| 7. INSPECT ECM (NSW TERMINAL VOLTAGE) |
Disconnect the B2 ECM connector.

Turn the ignition switch ON.
Measure the voltage according to the value(s) in the table below.
- Standard Resistance:
Tester Connections
Switch Conditions
Specified Conditions
Proceed To
NSW (B2-8) - Body ground
Ignition switch ON
11 to 14 V
A
Below 1.5 V
B
Reconnect the ECM connector.
|
|
||||
| A | ||
| ||
| 8. INSPECT IGNITION SWITCH |
Remove the ignition switch.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connections
Switch Conditions
Specified Conditions
1 - 2, 1 - 7
Ignition switch ON
10 kΩ or higher
Reinstall the ignition switch.
|
|
||||
| OK | |
| 9. INSPECT ECM (STA TERMINAL VOLTAGE) |
Disconnect the B3 ECM connector.

Turn the ignition switch ON.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connections
Switch Conditions
Specified Conditions
Proceed To
STA (B3-11) - Body ground
Ignition switch ON
11 to 14 V
A
Below 1.5 V
B
Reconnect the ECM connector.
|
|
||||
| A | ||
| ||