P0617 Starter Relay Circuit High
Diagnostic trouble codes · Vehicles built Nov 2010 – Jul 2012
Versions by build date: Jul 2007 – Nov 2007 Dec 2007 – Jul 2009 Aug 2009 – Oct 2010 Nov 2010 – Jul 2012 from Aug 2012
DESCRIPTION
While the engine is being cranked, the battery voltage is applied to terminal STA of the ECM. If the ECM detects the Starter Control (STA) signal while the vehicle is being driven, it determines that there is a malfunction in the STA circuit. The ECM then illuminates the MIL and sets the DTC.This monitor runs when the vehicle is driven at 20 km/h (12.4 mph) for over 20 seconds.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0617 |
When conditions (a), (b) and (c) met for 20 seconds (1 trip detection logic)
|
|
WIRING DIAGRAM




INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
- HINT:
- The following troubleshooting flowchart is based on the premise that the engine is cranked normally. If the engine will not crank, proceed to the problem symptoms table (Click here).
- Read freeze frame data using the intelligent tester. Freeze frame data record the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data, from the time the malfunction occurred.
- The following troubleshooting flowchart is based on the premise that the engine is cranked normally. If the engine will not crank, proceed to the problem symptoms table (Click here).
| 1. READ VALUE USING INTELLIGENT TESTER (STARTER SIGNAL) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.
Check the value displayed on the tester when the ignition switch is turned to the ON and START position.
- OK:
Ignition Switch Position
Starter Signal
ON
Close
START
Open
Result Result
Proceed to
OK
A
NG (Automatic Transmission models)
B
NG (Manual Transmission models)
C
|
|
||||
|
|
||||
| A | ||
| ||
| 2. READ VALUE USING INTELLIGENT TESTER (STARTER SIGNAL) |
![]() ![]() |
Disconnect the Park/Neutral Position (PNP) switch connector.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Starter Signal.
Check the value displayed on the tester when the ignition switch is turned ON.
Result Starter Signal
Proceed to
Remain ON
A
OFF
B
Text in Illustration *1
Front view of wire harness connector
(to PNP Switch)
|
|
||||
| A | |
| 3. INSPECT ECM (STA TERMINAL VOLTAGE) |
Disconnect the Park/Neutral Position (PNP) switch connector.

Disconnect the ECM connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
Proceed to
E81-10 (STA) - Body ground
Ignition switch ON
11 to 14 V
A
Below 1.5 V
B
| *1 |
Rear view of wire harness connector (to ECM) |
|
|
||||
| A | ||
| ||
| 4. INSPECT PARK/NEUTRAL POSITION SWITCH |
![]() ![]() |
Disconnect the Park/Neutral Position (PNP) switch connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
4 - 5
Shift lever position except P and N
10 kΩ or higher
2 - 5
All shift lever positions (P, R, N, D and S)
10 kΩ or higher
Result Result
Proceed to
Short between 4 and 5
A
Short between 2 and 5
B
Within standard range
C
Text in Illustration *1
Component without harness connected
(PNP Switch)
|
|
||||
|
|
||||
| A | |
| 5. REPLACE PARK/NEUTRAL POSITION SWITCH |
Replace the park/neutral position switch (Click here).
| NEXT | |
| 6. INSPECT IGNITION SWITCH |
Remove the ignition switch.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
1 - 2, 1 - 7
Ignition switch ON
10 kΩ or higher
|
|
||||
| OK | |
| 7. INSPECT ECM (NSW TERMINAL VOLTAGE) |
Disconnect the ECM connector.

Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
Proceed to
B48-2 (NSW) - Body ground
Ignition switch ON
11 to 14 V
A
Below 1.5 V
B
| *1 |
Rear view of wire harness connector (to ECM) |
|
|
||||
| A | ||
| ||
| 8. INSPECT IGNITION SWITCH |
Remove the ignition switch.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
1 - 2, 1 - 7
Ignition switch ON
10 kΩ or higher
|
|
||||
| OK | |
| 9. INSPECT ECM (STA TERMINAL VOLTAGE) |
Disconnect the ECM connector.

Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
Proceed to
E81-10 (STA) - Body ground
Ignition switch ON
11 to 14 V
A
Below 1.5 V
B
Text in Illustration *1
Rear view of wire harness connector
(to ECM)
|
|
||||
| A | ||
| ||