Check CAN Bus Line for Short to +B (RHD Models)
Circuit diagnosis · Vehicles built Aug 2011 – Jul 2012
Versions by build date: Nov 2010 – Jul 2011 Aug 2011 – Jul 2012 from Aug 2012
DESCRIPTION
There may be a short circuit between the CAN bus line and +B when there is resistance between terminals 6 (CANH) and 16 (BAT) or terminals 14 (CANL) and 16 (BAT) of the DLC3.| Symptom |
Trouble Area |
| There is resistance between terminals 6 (CANH) and 16 (BAT) or terminals 14 (CANL) and 16 (BAT) of the DLC3. |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Turn the ignition switch off before measuring the resistances between CAN bus main wires and between CAN bus branch wires.
- Turn the ignition switch off before inspecting CAN bus wires for a ground short.
- After the ignition switch is turned off, check that the key reminder warning system and light reminder warning system are not operating.
- Before measuring the resistance, leave the vehicle as is for at least 1 minute and do not operate the ignition switch, any other switches or the doors. If any doors need to be opened in order to check connectors, open the doors and leave them open.
- Turn the ignition switch off before measuring the resistances between CAN bus main wires and between CAN bus branch wires.
- HINT:
- Operating the ignition switch, any other switches or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.
- Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below may help determine the cause of the malfunction.
- Operating the ignition switch, any other switches or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.
- CAUTION:
- Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).
| NEXT | |
| 2. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (DLC3 BRANCH WIRE) |
Disconnect the E91 CAN junction connector No. 2 connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E1-6 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
E1-14 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of DLC3
|
|
||||
| OK | |
| 3. CONNECT CONNECTOR |
Reconnect the E91 CAN junction connector No. 2 connector.
| NEXT | |
| 4. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (CAN JUNCTION CONNECTOR NO. 3 SIDE) |
Disconnect the A43 CAN junction connector No. 3 connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E1-6 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
E1-14 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of DLC3
|
|
||||
| OK | |
| 5. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (CAN JUNCTION CONNECTOR NO. 3 - COMBINATION METER ASSEMBLY (COMBINATION METER ECU)) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
A43-2 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
A43-13 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to CAN Junction Connector No. 3)
*b
Front view of DLC3
|
|
||||
| OK | |
| 6. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (CAN JUNCTION CONNECTOR NO. 3 - MASTER CYLINDER SOLENOID (SKID CONTROL ECU)) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
A43-1 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
A43-12 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to CAN Junction Connector No. 3)
*b
Front view of DLC3
|
|
||||
| OK | ||
| ||
| 7. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (CAN JUNCTION CONNECTOR NO. 3 - CAN JUNCTION CONNECTOR NO. 2) |
Disconnect the E92 CAN junction connector No. 2 connector.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
A43-3 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
A43-14 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to CAN Junction Connector No. 3)
*b
Front view of DLC3
|
|
||||
| OK | |
| 8. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (CAN JUNCTION CONNECTOR NO. 1 SIDE) |
Disconnect the E95 CAN junction connector No. 1 connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E1-6 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
E1-14 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of DLC3
|
|
||||
| OK | |
| 9. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (CAN JUNCTION CONNECTOR NO. 2 - CAN JUNCTION CONNECTOR NO. 1) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E92-2 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
E92-8 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to CAN Junction Connector No. 2)
*b
Front view of DLC3
|
|
||||
| OK | |
| 10. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (CAN JUNCTION CONNECTOR NO. 1 - ECM) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E95-1 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
E95-12 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to CAN Junction Connector No. 1)
*b
Front view of DLC3
|
|
||||
| OK | |
| 11. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (CAN JUNCTION CONNECTOR NO. 1 - YAW RATE SENSOR) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E95-2 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
E95-13 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to CAN Junction Connector No. 1)
*b
Front view of DLC3
|
|
||||
| OK | |
| 12. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (CAN JUNCTION CONNECTOR NO. 1 - AIRBAG SENSOR ASSEMBLY) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E95-7 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
E95-18 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to CAN Junction Connector No. 1)
*b
Front view of DLC3
|
|
||||
| OK | ||
| ||
| 13. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (CAN JUNCTION CONNECTOR NO. 2 - STEERING ANGLE SENSOR) |
Disconnect the E91 CAN junction connector No. 2 connector.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E91-5 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
E91-11 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to CAN Junction Connector No. 2)
*b
Front view of DLC3
|
|
||||
| OK | ||
| ||
| 14. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (COMBINATION METER ASSEMBLY (COMBINATION METER ECU)) |
Disconnect the E14 combination meter assembly (combination meter ECU) connector.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
A43-2 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
A43-13 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to CAN Junction Connector No. 3)
*b
Front view of DLC3
|
|
||||
| OK | ||
| ||
| 15. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (MASTER CYLINDER SOLENOID (SKID CONTROL ECU)) |
Disconnect the A4 master cylinder solenoid (skid control ECU) connector.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
A43-1 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
A43-12 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to CAN Junction Connector No. 3)
*b
Front view of DLC3
|
|
||||
| OK | ||
| ||
| 16. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (ECM) |
Disconnect the E81 ECM connector.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E95-1 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
E95-12 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to CAN Junction Connector No. 1)
*b
Front view of DLC3
|
|
||||
| OK | ||
| ||
| 17. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (YAW RATE SENSOR) |
Disconnect the E83 yaw rate sensor connector.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E95-2 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
E95-13 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to CAN Junction Connector No. 1)
*b
Front view of DLC3
|
|
||||
| OK | ||
| ||
| 18. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (AIRBAG SENSOR ASSEMBLY) |
Disconnect the E29 airbag sensor assembly connector.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E95-7 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
E95-18 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to CAN Junction Connector No. 1)
*b
Front view of DLC3
|
|
||||
| OK | ||
| ||
| 19. CHECK FOR SHORT TO B+ IN CAN BUS WIRE (STEERING ANGLE SENSOR) |
Disconnect the E16 steering angle sensor connector.
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E91-5 (CANH) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
E91-11 (CANL) - E1-16 (BAT)
Ignition switch off
6 kΩ or higher
Text in Illustration *a
Front view of wire harness connector
(to CAN Junction Connector No. 2)
*b
Front view of DLC3
|
|
||||
| OK | ||
| ||