DTC P0031 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 1 Sensor 1) |
DTC P0032 Oxygen (A/F) Sensor Heater Control Circuit High (Bank 1 Sensor 1) |
DTC P0051 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 2 Sensor 1) |
DTC P0052 Oxygen (A/F) Sensor Heater Control Circuit High (Bank 2 Sensor 1) |
DTC P101D A/F Sensor Heater Circuit Performance Bank 1 Sensor 1 Stuck ON |
DTC P103D A/F Sensor Heater Circuit Performance Bank 2 Sensor 1 Stuck ON |



| DTC No. | DTC Detection Condition | Trouble Area |
| P0031 P0051 | Air-Fuel Ratio (A/F) sensor heater current is less than 0.8 A (1 trip detection logic) |
|
| P0032 P0052 | Air-Fuel Ratio (A/F) sensor heater current failure (1 trip detection logic) |
|
| P101D P103D | The heater current is higher than the specified value while the heater is not operating (1 trip detection logic). | ECM |
| Related DTCs | P0031: Air fuel ratio sensor heater (for bank 1 sensor 1) open/short (Low electrical current) P0032: Air fuel ratio sensor heater (for bank 1 sensor 1) open/short (High electrical current) P0051: Air fuel ratio sensor heater (for bank 2 sensor 1) open/short (Low electrical current) P0052: Air fuel ratio sensor heater (for bank 2 sensor 1) open/short (High electrical current) P101D: Air fuel ratio sensor heater (for bank 1 sensor 1) performance P103D: Air fuel ratio sensor heater (for bank 2 sensor 1) performance |
| Required Sensors/Components (Main) | Air fuel ratio sensor heater |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 10 seconds: P0031 and P0051 10.24 seconds: P0032 and P0052 1 second: P101D and P103D |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | None |
| One of following conditions met | - |
| A. All of following conditions met | - |
| Battery voltage | 10.5 V or more |
| Time after heater ON | 5 seconds or more |
| Active heater OFF control | Not operating |
| Active heater ON control | Not operating |
| Output duty cycle | 10% or more |
| B. All of following conditions met | - |
| A/F sensor heater performance fail (P101D, P103D) | Not detected |
| Output duty cycle | 30% or more |
| Battery voltage | 10.5 V or more |
| Time after heater ON | 5 seconds or more |
| Output duty cycle | More than 0% |
| Active heater OFF control | Not operating |
| Active heater ON control | Not operating |
| Battery voltage | 10.5 V or more |
| Time after heater ON | 5 seconds or more |
| Output duty cycle | 10% or more, and less than 60% |
| Heater ON current | 0.8 A or more |
| Active heater OFF control | Not operating |
| Active heater ON control | Not operating |
| A/F sensor heater low current fail (P0031, P0051) | Not detected |
| Heater ON current | Less than 0.8 A |
| All of following conditions met | - |
| Command to heater output | ON |
| Heater monitor IC high current limiter monitor input | Fail |
| All of following conditions met | - |
| Heater monitor IC high current limiter monitor input | Fail |
| Heater OFF current | More than 11 A |
| Heater ON current | 0.8 A or more |
| All of following conditions met | - |
| Command to heater output | ON |
| Heater monitor IC high current limiter monitor input | Pass |
| Heater OFF current | 11 A or less |

| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|
| 1.INSPECT AIR FUEL RATIO SENSOR (HEATER RESISTANCE) |
Inspect the A/F sensor (Click here).
|
| ||||
| OK | |
| 2.CHECK TERMINAL VOLTAGE (+B OF A/F SENSOR) |
![]() |
Disconnect the A/F sensor connectors.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B33-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| B31-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to A/F Sensor) |
| *b | Bank 1 |
| *c | Bank 2 |
| Result | Proceed to |
| NG | A |
| OK | B |
|
| ||||
| A | |
| 3.INSPECT AIR FUEL RATIO SENSOR HEATER RELAY |
![]() |
Remove the air fuel ratio sensor heater relay (A/F HEATER relay) from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | Battery voltage not applied | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (A/F HEATER RELAY - A/F SENSOR AND BODY GROUND) |
Disconnect the B33 and B31 A/F sensor connectors.
Remove the A/F HEATER relay from the engine room relay block .
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B33-2 (+B) - 3 (A/F HEATER relay) | Always | Below 1 Ω |
| B31-2 (+B) - 3 (A/F HEATER relay) | Always | Below 1 Ω |
| 2 (A/F HEATER relay) - Body ground | Always | Below 1 Ω |
| B33-2 (+B) or 3 (A/F HEATER relay) - Body ground | Always | 10 kΩ or higher |
| B31-2 (+B) or 3 (A/F HEATER relay) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (A/F SENSOR - ECM) |
Disconnect the B33 and B31 A/F sensor connectors.
Disconnect the B50 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| B33-1 (HA1A) - B50-17 (HA1A) | Always | Below 1 Ω |
| B31-1 (HA2A) - B50-19 (HA2A) | Always | Below 1 Ω |
| B33-1 (HA1A) or B50-17 (HA1A) - Body ground | Always | 10 kΩ or higher |
| B31-1 (HA2A) or B50-19 (HA2A) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 6.CHECK WHETHER DTC OUTPUT RECURS |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Clear the DTCs (Click here).
Start the engine.
Drive the vehicle in accordance with the driving pattern described in the Confirmation Driving Pattern.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read the output pending DTCs.
| Result | Proceed to |
| No pending DTC is output | A |
| Pending DTC P0031, P0032, P0051, P0052, P101D or P103D is output | B |
|
| ||||
| A | ||
| ||