P0405 Exhaust Gas Recirculation Sensor "A" Circuit Low
Diagnostic trouble codes · Vehicles built Oct 2014 – Dec 2014
Also covers:
- P0406 Exhaust Gas Recirculation Sensor "A" Circuit High
Versions by build date: Oct 2014 – Dec 2014 Jan 2015 – Nov 2015 Dec 2015 – Mar 2016 Apr 2016 – Dec 2016 from Jan 2017
DESCRIPTION
The EGR valve position sensor is mounted on the EGR valve and is used for detecting the lift amount of the valve. The lift amount detected by the sensor is provided to the ECM as feedback. The ECM then regulates the lift amount of the valve in accordance with engine running conditions.| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
| Ignition switch ON for 5 seconds |
EGR valve position sensor output voltage is below 0.1 V for more than 5 seconds (1 trip detection logic). |
|
| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
| Ignition switch ON for 5 seconds |
EGR valve position sensor output voltage is more than 4.9 V for higher than 5 seconds (1 trip detection logic). |
|
MONITOR DESCRIPTION
When the output voltage of the EGR valve position sensor deviates from the normal operating range of 0.1 to 4.9 V for more than 5 seconds, the ECM interprets this as a malfunction of the sensor circuit and illuminates the MIL.WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
- HINT:
- Read freeze frame data using the GTS. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
| 1. CHECK TERMINAL VOLTAGE (EGR VALVE POSITION SENSOR CONNECTOR) |
Disconnect the EGR valve position sensor connector.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
D52-1 (VC) - D52-2 (E2)
Ignition switch ON
4.5 to 5.5 V
Text in Illustration *a
Front view of wire harness connector
(to EGR Valve Position Sensor)
Reconnect the electric vacuum regulating valve assembly connector.
|
|
||||
| OK | |
| 2. INSPECT EGR VALVE POSITION SENSOR |
Inspect the EGR valve position sensor (Click here).
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (EGR VALVE POSITION SENSOR - ECM) |
Disconnect the EGR valve position sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
D52-1 (VC) - D98-75 (VC)
Always
Below 1 Ω
D52-3 (EGLS) - D98-118 (EGLS)
Always
Below 1 Ω
D52-2 (E2) - D98-92 (EEGL)
Always
Below 1 Ω
D52-1 (VC) or D98-75 (VC) - Body ground
Always
10 kΩ or higher
D52-3 (EGLS) or D98-118 (EGLS) - Body ground
Always
10 kΩ or higher
Reconnect the electric vacuum regulating valve assembly connector.
Reconnect the ECM connector.
|
|
||||
| OK | |
| 4. REPLACE ECM |
Replace the ECM (Click here).
|
|
||||
| 5. REPLACE ELECTRIC EGR CONTROL VALVE ASSEMBLY |
Replace the electric EGR control valve assembly (Click here).
|
|
||||
| 6. REPAIR OR REPLACE HARNESS OR CONNECTOR |
Repair or replace the harness or connector.
| NEXT | |
| 7. CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED |
Connect the GTS to the DLC3.
Clear the DTCs (Click here).
Turn the ignition switch to ON for 5 seconds or more.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Confirm that the DTC is not output again.
| NEXT | ||
| ||