P245C Exhaust Gas Recirculation Cooler Bypass Control Circuit Low
Diagnostic trouble codes · Vehicles built from Jan 2017
Also covers:
- P245D Exhaust Gas Recirculation Cooler Bypass Control Circuit High
DESCRIPTION
The No. 1 vacuum switching valve assembly (for EGR bypass valve) is controlled by the ECM, and the opening and closing of the EGR cooler bypass valve is performed according to the vacuum applied by the vacuum pump.| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
| Ignition switch ON for 3 seconds or more |
Open or short in the No. 1 vacuum switching valve assembly (for EGR bypass valve) for 3 seconds (1 trip detection logic). |
|
| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
| Ignition switch ON for 3 seconds or more |
Open or short in the No. 1 vacuum switching valve assembly (for EGR bypass valve) for 3 seconds (1 trip detection logic). |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses of circuits related to this system before performing the following inspection procedure.
- After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
- Inspect the fuses of circuits related to this system before performing the following inspection procedure.
- HINT:
- Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
| 1. INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY (FOR EGR BYPASS VALVE) |
Inspect the No. 1 vacuum switching valve assembly (for EGR bypass valve) (Click here).
|
|
||||
| OK | |
| 2. CHECK NO. 1 VACUUM SWITCHING VALVE ASSEMBLY (FOR EGR BYPASS VALVE) (POWER SOURCE CIRCUIT) |
Disconnect the No. 1 vacuum switching valve assembly (for EGR bypass valve) connector.

Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
Switch Condition
Specified Condition
D74-1 (+B) - Body ground
Ignition switch ON
11 to 14 V
Text in Illustration *a
Front view of wire harness connector
(to No. 1 Vacuum Switching Valve Assembly (for EGR Bypass Valve))
Reconnect the No. 1 vacuum switching valve (for EGR bypass valve) connector.
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (NO. 1VACUUM SWITCHING VALVE ASSEMBLY (FOR EGR BYPASS VALVE) - ECM) |
Disconnect the No. 1 vacuum switching valve assembly (for EGR bypass valve) connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
D74-2 (ECBV) - D134-45 (ECBV)
Always
Below 1 Ω
D74-2 (ECBV) or D134-45 (ECBV) - Body ground and other terminals
Always
10 kΩ or higher
Reconnect the No. 1 vacuum switching valve assembly (for EGR bypass valve) connector.
Reconnect the ECM connector.
|
|
||||
| OK | |
| 4. REPLACE ECM |
Replace the ECM (Click here).
|
|
||||
| 5. REPLACE NO. 1 VACUUM SWITCHING VALVE ASSEMBLY (FOR EGR BYPASS VALVE) |
Replace the No. 1 vacuum switching valve assembly (for EGR bypass valve) (Click here).
|
|
||||
| 6. REPAIR OR REPLACE HARNESS OR CONNECTOR |
Repair or replace the harness or connector.
- HINT:
- If the voltage at the vacuum switching valve assembly (for EGR bypass valve) connector is not 11 to 14 V, repair or replace the harness and connector between the No. 1 vacuum switching valve assembly (for EGR bypass valve) and No. 1 integration relay.
| NEXT | |
| 7. CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED |
Connect the GTS to the DLC3.
Clear the DTCs (Click here).
Turn the ignition switch to ON for 3 seconds.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Confirm that the DTC is not output again.
| NEXT | ||
| ||