27020
1.INSTALL GENERATOR ASSEMBLY
Install the generator bracket to the generator assembly with the bolt.
Install the generator assembly with the 2 bolts.
Attach the wire harness clamp and connect the wire harness to the generator bracket.
Connect the wire harness to terminal B with the nut.
Install the terminal cap.
Connect the generator connector to the generator assembly.
16361A
2.INSTALL FAN AND GENERATOR V BELT
17303T
3.INSTALL AIR PIPE SUB-ASSEMBLY
12601B
4.INSTALL NO. 1 ENGINE COVER SUB-ASSEMBLY
5.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
6. INITIALIZATION AFTER RECONNECTING BATTERY TERMINAL
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART