Home › Engine / Hybrid System › 1GD-FTV (ENGINE CONTROL) › ECD SYSTEM (w/ Exhaust Gas Temperature Sensor for EGR) › 2019.06–2021.07
RM35X0E _51 Engine / Hybrid System _078856 1GD-FTV ENGINE CONTROL _0395991 ECD SYSTEM(w/ Exhaust Gas Temperature Sensor for EGR) C

1GD-FTV ENGINE CONTROL  ECD SYSTEM(w/ Exhaust Gas Temperature Sensor for EGR)  P20F400  Reductant Consumption Too Low  


DESCRIPTION

Refer to DTC P20EE00.

Click hereEngine / Hybrid System>1GD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ Exhaust Gas Temperature Sensor for EGR)>P20EE00

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory Note
P20F400 Reductant Consumption Too Low There is a deviation between the amount of change in the remaining amount shown on the urea tank level sensor and the urea solution injection command value (1 trip detection logic).
·

Urea injector set

·

Urea pump


- DTC stored SAE Code: P20F4

MONITOR DESCRIPTION

When there is a large deviation between the remaining amount estimated from the urea tank level sensor and the remaining amount estimated from the calculated urea solution injection command value, the monitor determines that the urea solution injection volume has decreased and detects P20F400.

CONFIRMATION DRIVING PATTERN

DTC No. DTC Detection Drive Pattern
P20F400 -

CAUTION / NOTICE / HINT

NOTICE:
Handling urea solution
·

Wear protective equipment as necessary (protective glasses and gloves).

·

Do not dilute urea solution.

·

If urea solution contacts your eyes or skin, immediately wash the contacted area with a large amount of water and consult a doctor as necessary.

·

If urea solution dries, it deposits a white powder. Also, if urea solution contacts metals such as copper and aluminum for a long period of time, it may promote corrosion. Therefore, if urea solution is spilled, dampen a cloth or other item and wipe it up or rinse the area with cool or warm water.


Handling the urea injector set
·

The urea injector set is a precision instrument. Take necessary precautions for installation and shipping. Do not use the part if it has been struck or dropped.

·

If the urea solution remaining inside the urea injector set dries out, it may become unable to inject urea solution. Therefore, conduct urea tube with heater assembly installation and removal quickly.

·

If the urea solution dries out and deposition occurs, urea may cling to the O-ring of the pipe and cause seal problems. Therefore, clean the urea tube with heater assembly and intake port of the urea injector set with water before attaching them.

·

Perform this procedure in an environment where urea solution will not freeze.



HINT:

Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.


PROCEDURE

1.CHECK DTC OUTPUT
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG) and turn the GTS on.


c.

Enter the following menus: Powertrain / Engine and Transmission / Trouble Codes.

Powertrain > Engine and Transmission > Trouble Codes
50001 456

d.

Read the DTCs.

Result:
Result Proceed to
DTC P20F400 is output A
P20F400 and other DTCs are output B




A

2.CHECK UREA INJECTION PIPES (CHECK DEPOSIT)

B

12.GO TO DTC CHART
2.CHECK UREA INJECTION PIPES (CHECK DEPOSIT)
HINT:

If there are deposits around the urea injector, injection may be inhibited, reducing purification performance.


a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG) and turn the GTS on.


c.

Enter the following menus: Powertrain / Engine and Transmission / Active Test / Reductant Pump Check (Backward).

Powertrain > Engine and Transmission > Active Test
Tester Display
Reductant Pump Check (Backward)
50004 456 16

d.

Perform the Active Test.


e.

Enter the following menus: Powertrain / Engine and Transmission / Active Test / Reductant Purge.

Powertrain > Engine and Transmission > Active Test
Tester Display
Reductant Purge
50004 456 17

f.

Perform the Active Test.

HINT:

Perform the Reductant Purge to draw the urea solution back into the urea tank sub-assembly from the urea injector set.



g.

After performing the Active Test, remove the urea injector set from the front exhaust pipe assembly.

Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA INJECTOR>REMOVAL

HINT:

Do not disconnect the urea injector from the urea tube with heater assembly.



h.
A383896C02
2.125,1.229 2.385,0.74 2.385,0.74 2.552,0.74 false 0.969,2.802 1.313,3.021 0.344,0.219 11 false *a 2.583,0.667 2.927,0.885 0.344,0.219 11 false *1
*a Exhaust Pipe Connection Area to Check
*1 Front Exhaust Pipe Assembly


Check that there is no white matter deposited by urea solution on the connection area of the front exhaust pipe.

HINT:

After checking for deposits, use a cover, etc., to prevent foreign matter from entering the front exhaust pipe.



Result:
Result Proceed to
No white matter is deposited by urea solution on connection area of front exhaust pipe A
White matter is deposited by urea solution on connection area of front exhaust pipe B



A

3.PERFORM ACTIVE TEST USING GTS (UREA INJECTOR SET OPERATION CHECK)

B

11.REMOVE DEPOSIT
3.PERFORM ACTIVE TEST USING GTS (UREA INJECTOR SET OPERATION CHECK)
HINT:

If there is a malfunction in the urea injector set, NOx purification performance will be reduced.


a.

Use a cover, etc., to prevent foreign matter from entering the front exhaust pipe where the urea injector set was removed.


b.

Enter the following menus: Powertrain / Engine and Transmission / Active Test / Reductant Injection Valve.

Powertrain > Engine and Transmission > Active Test
Tester Display
Reductant Injection Valve
50004 456 13

c.

Perform the Active Test and check that operation sounds can be heard from the urea injector set.

OK:

Sound of urea injector set operation can be heard (a ticking sound).


HINT:

Even after checking is complete, do not install the urea injector removed from the front exhaust pipe yet.



Result:
Proceed to
OK
NG



OK

4.UREA INJECTOR INJECTION STATE CHECK

NG

10.REPLACE UREA INJECTOR SET
4.UREA INJECTOR INJECTION STATE CHECK
a.

Enter the following menus: Powertrain / Engine and Transmission / Utility / Reductant Injection Valve Check.

Powertrain > Engine and Transmission > Utility
Tester Display
Reductant Injection Valve Check
50005 456 4601

b.

Execute the Reductant Injection Valve Check and check the injection condition of the urea injector set.

HINT:
·

This test performs operations from urea solution refueling up to injection.

·

The pressure inside the pipe may increase during urea solution refueling, intermittently opening the urea injector set and causing urea solution to leak out.

·

If the urea injector set becomes stuck open during urea solution refueling, once this test starts, intermittent injections will not occur and urea solution will leak out.

·

Urea solution is intermittently injected by the urea injector set.



A362197C02
3.875,1.167 4.688,0.177 4.688,0.177 4.031,0.75 false 3.594,0.813 4.688,0.177 4.688,0.177 4.865,0.177 false 0.344,0.531 0.656,0.688 0.313,0.156 10 false *1 4.917,0.104 5.229,0.26 0.313,0.156 10 false *2 4.99,0.563 5.302,0.719 0.313,0.156 10 false *a 3.99,1.74 4.302,1.896 0.313,0.156 10 false *b
*1 Urea Injector Set *2 Spray Hole
*a Urea injector set normal *b Urea injector set abnormal


Result:
Result Proceed to
Urea injector set normal A
Urea injector set abnormal B


HINT:

Even after checking is complete, do not install the urea injector removed from the front exhaust pipe yet.



c.

Wash off any matter deposited by the urea solution.

NOTICE:
·

Do not damage the urea injector set when washing it.

·

Make sure to leave the connector connected when washing to prevent water from entering via the connector.

·

Sufficiently wipe the area so that no urea solution remains on the flange sealing surface.

·

After completing work, check that 3 streams of liquid are sprayed from the urea injector set.





A

5.CHECK UREA INJECTOR INJECTION VOLUME

B

10.REPLACE UREA INJECTOR SET
5.CHECK UREA INJECTOR INJECTION VOLUME
a.

Set the urea injector set to the graduated cylinder to measure the injection volume of the urea injector set.


b.

Enter the following menus: Powertrain / Engine and Transmission / Utility / Reductant Injection Valve Check.

Powertrain > Engine and Transmission > Utility
Tester Display
Reductant Injection Valve Check
50005 456 4601

c.
A449031C01
1.958,1.76 2.688,1.542 false 0.417,0.281 1.698,1.146 true 0.229,0.177 0.542,0.375 0.313,0.198 10 false *1 2.729,1.438 3.042,1.635 0.313,0.198 10 false *2
*1 Urea Injector Set
*2 Graduated Cylinder


Execute the Reductant Injection Valve Check and measure the amount of urea injected in 1 minute.

HINT:
·

This test performs operations from urea solution refueling up to injection.

·

The pressure inside the pipe may increase during urea solution refueling, intermittently opening the urea injector set and causing urea solution to leak out.

·

If the urea injector set becomes stuck open during urea solution refueling, once this test starts, intermittent injections will not occur and urea solution will leak out.

·

Urea solution is intermittently injected by the urea injector set.



Result:
Result Proceed to
1-minute injection volume is 13 cc or more A
1-minute injection volume is less than 13 cc B


HINT:

Even after checking is complete, do not install the urea injector removed from the front exhaust pipe yet.



d.

Wash off any matter deposited by the urea solution.

NOTICE:
·

Do not damage the urea injector set when washing it.

·

Make sure to leave the connector connected when washing to prevent water from entering via the connector.

·

Sufficiently wipe the area so that no urea solution remains on the flange sealing surface.

·

After completing work, check that 3 streams of liquid are sprayed from the urea injector set.





A

6.READ VALUE USING GTS (REDUCTANT LEVEL)

B

10.REPLACE UREA INJECTOR SET
6.READ VALUE USING GTS (REDUCTANT LEVEL)
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG) and turn the GTS on.


c.

Enter the following menus: Powertrain / Engine and Transmission / Data List / Diesel Exhaust / Reductant Level.

Powertrain > Engine and Transmission > Data List
Tester Display
Reductant Level
50003 456 135

d.

Check the value of "Reductant Level". If the value of the level is 1, refill the urea solution.

Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA TANK>REFILL

HINT:

Refill approximately 3 to 5 L.



e.

Disconnect the urea tube with heater assembly from the urea injector set.

Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA INJECTOR>REMOVAL

NOTICE:

If the urea solution remaining inside the urea injector set dries out, it may become unable to inject urea solution. Therefore, seal the urea injector set with an item such as a cover or rubber cap so that the inside does not dry out.



f.

Prepare a bucket or other receptacle for collecting urea solution from the urea tube with heater assembly.


Result:
Proceed to
NEXT



NEXT

7.PERFORM ACTIVE TEST USING GTS (REDUCTANT DISCHARGE)
7.PERFORM ACTIVE TEST USING GTS (REDUCTANT DISCHARGE)
a.

Enter the following menus: Powertrain / Engine and Transmission / Active Test / Reductant Pump Check (Backward).

Powertrain > Engine and Transmission > Active Test
Tester Display
Reductant Pump Check (Backward)
50004 456 16

b.

Perform the Active Test.


c.

Enter the following menus: Powertrain / Engine and Transmission / Active Test / Reductant Pump Check (Backward) / Data List / Diesel Exhaust / Reductant Level.

Powertrain > Engine and Transmission > Active Test
Active Test Display
Reductant Pump Check (Backward)
Data List Display
Reductant Level
50004 456 16 135

d.

Execute the Active Test and check the urea solution level.

NOTICE:

When the Active Test is executed, urea solution will come out of the urea pipe. Collect the urea solution with a bucket or other receptacle.



e.

Check if the urea solution level decreases during the Active Test.

HINT:

When the level sensor value is stuck, the value does not decrease even when the urea solution is released.



f.

After completing the Active Test, refill approximately 3 to 5 L of urea solution.

Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA TANK>REFILL

HINT:

When the level sensor value is stuck, the value does not increase even when the urea solution is refilled.



g.

Check the urea solution level when the urea solution was drained, and also when it was refilled.

OK:

Urea solution level changes.



Result:
Proceed to
OK
NG



OK

9.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED

NG

8.REPLACE UREA PUMP
8.REPLACE UREA PUMP

Result:
Proceed to
NEXT



NEXT

9.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
9.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG) and turn the GTS on.


c.

Clear the DTCs.

Powertrain > Engine and Transmission > Clear DTCs
50002 456

d.

Warm up the engine (engine coolant temperature is 75°C (167°F) or higher).



f.

Enter the following menus: Powertrain / Engine and Transmission / Trouble Codes.

Powertrain > Engine and Transmission > Trouble Codes
50001 456

g.

Confirm that the DTCs are not output again.


Result:
Proceed to
NEXT



NEXT

END

10.REPLACE UREA INJECTOR SET

Result:
Proceed to
NEXT



NEXT

9.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
11.REMOVE DEPOSIT
a.

Clean any deposits from communicating portions of the front exhaust pipe.

HINT:

After washing, make sure to wipe off the flange surface so that no urea solution remains.



Result:
Proceed to
NEXT



NEXT

3.PERFORM ACTIVE TEST USING GTS (UREA INJECTOR SET OPERATION CHECK)
12.GO TO DTC CHART

b.

Repair any malfunctioning parts indicated by related DTCs.


Result:
Proceed to
NEXT



NEXT

9.CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED