The urea Selective Catalytic Reduction (SCR) system injects urea (NH3) into the catalyst to purify NOx.
After the engine is started, the SCR catalyst is heated up for a short period of time before the urea SCR system is activated.
After the SCR catalyst reaches a temperature appropriate for purifying NOx, the urea pump raises the pressure of the urea solution to approximately 500 kPa, delivering pressurized urea solution from the urea tank assembly to the urea injector set.
The urea injector opens the needle valve according to operation signals sent by the urea pump control ECU. When a catalyst temperature is reached at which NOx expelled from the engine will react with ammonia, engine exhaust gas (NOx) and an optimal quantity of urea solution based on the catalyst temperature are injected from the urea injector set to the mixer. In the mixer, atomized and dispersed urea solution is converted to ammonia through hydrolysis, which reacts with the NOx, rendering it harmless.
| *1 | Exhaust Gas | *2 | Mixer |
| *3 | SCR Catalyst | *4 | No. 4 Exhaust Gas Temperature Sensor |
| *5 | No. 1 Nitrogen Oxides Sensor | *6 | No. 1 Nitrogen Oxides Sensor Control Unit |
| *7 | No. 2 Nitrogen Oxides Sensor | *8 | No. 2 Nitrogen Oxides Sensor Control Unit |
| *9 | Urea Solution | *10 | Urea pump
·
Temperature sensor ·
Pressure sensor ·
Pump ·
Tank heater ·
Level sensor |
| *11 | Urea Pump Control ECU | *12 | ECM |
| *13 | CAN Communication Line | *14 | Urea Tube with Heater Assembly |
| *15 | to ECM | *16 | Urea Injector Set |
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory | Note |
|---|---|---|---|---|---|---|
| P20EE00 | SCR NOx Catalyst Efficiency Below Threshold Bank 1 | After comparing the No. 1 nitrogen oxides sensor value with the No. 2 nitrogen oxides sensor value while the urea SCR system is operating, the NOx purification rate is equal to or less than a fixed value.
(2 trip detection logic) |
·
Urea injector set ·
Front exhaust pipe assembly (SCR catalyst) ·
No. 1 nitrogen oxides sensor ·
No. 2 nitrogen oxides sensor ·
Urea solution |
Comes on | DTC stored | SAE Code: P20EE |
When P20EE00 is output, it may be the result of the following malfunction modes.
The urea injector set cannot perform injection as commanded.
The concentration of urea solution is thick, or the urea solution has deteriorated.
The output of the No. 1 nitrogen oxides sensor is offset on the low side.
The output of the No. 2 nitrogen oxides sensor is offset on the high side.
The SCR catalyst has deteriorated.
| DTC No. | DTC Detection Drive Pattern |
|---|---|
| P20EE00 | PM forced regeneration |
Wear protective equipment as necessary (protective glasses and gloves).
Do not dilute urea solution.
If urea solution contacts your eyes or skin, immediately wash the contacted area with a large amount of water and consult a doctor as necessary.
If urea solution dries, it deposits a white powder. Also, if urea solution contacts metals such as copper and aluminum for a long period of time, it may promote corrosion. Therefore, if urea solution is spilled, dampen a cloth or other item and wipe it up or rinse the area with cool or warm water.
The urea injector set is a precision instrument. Take necessary precautions for installation and shipping. Do not use the part if it has been struck or dropped.
If the urea solution remaining inside the urea injector set dries out, it may become unable to inject urea solution. Therefore, conduct urea tube with heater assembly installation and removal quickly.
If the urea solution dries out and deposition occurs, urea may cling to the O-ring of the pipe and cause seal problems. Therefore, clean the urea tube with heater assembly and intake port of the urea injector set with water before attaching them.
Perform this procedure in an environment where urea solution will not freeze.
Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
Ask the customer whether the vehicle has previously been refilled with something other than AdBlue (conforming to ISO 22241-1) due to a lack of urea solution.
If the urea solution has been diluted due to the addition of something such as water, purification performance will decrease.
| Result | Proceed to |
|---|---|
| Vehicle has been refilled with something other than AdBlue (conforming to ISO 22241-1) | A |
| Except above | B |
A
B
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Enter the following menus: Powertrain / Engine / Active Test / Reductant Pump Check (Backward).
| Tester Display |
|---|
| Reductant Pump Check (Backward) |
Perform the Active Test.
Enter the following menus: Powertrain / Engine / Active Test / Reductant Purge.
| Tester Display |
|---|
| Reductant Purge |
Perform the Active Test.
Perform the Reductant Purge to draw the urea solution back into the urea tank sub-assembly from the urea injector set.
After performing the Active Test, remove the urea tube with heater assembly from the urea injector set.
Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA INJECTOR>REMOVAL
If the urea solution remaining inside the urea injector set dries out, it may become unable to inject urea solution.
Therefore, seal the urea injector set with an item such as a cover or rubber cap so that the inside does not dry out.
Prepare a bucket or other receptacle for collecting urea solution from the urea tube with heater assembly.
Enter the following menus: Powertrain / Engine / Active Test / Reductant Discharge.
| Tester Display |
|---|
| Reductant Discharge |
Perform the Active Test to drain all the urea solution.
After fully draining the urea solution, refill with AdBlue (conforming to ISO 22241-1).
Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA TANK>REFILL
| Proceed to |
|---|
| NEXT |
NEXT
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Enter the following menus: Powertrain / Engine / Trouble Codes.
Read the DTCs.
| Result | Proceed to |
|---|---|
| DTC P20EE00 is output | A |
| DTC P20EE00 and other DTCs are output* | B |
*: If codes other than DTC P20EE00 are output, perform troubleshooting for those DTCs first.
A
B
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Enter the following menus: Powertrain / Engine / Data List / Engine Speed and Mass Air Flow Sensor.
| Tester Display |
|---|
| Engine Speed |
| Mass Air Flow Sensor |
Start the engine and read the value when 30 seconds has elapsed.
| Engine Speed | Mass Air Flow Sensor |
|---|---|
| Idling | ·
0.5 to 15 gm/sec (EGR on) ·
10 to 22 gm/sec (EGR off) |
| 3000 rpm (without load) | ·
42 to 89 gm/sec (EGR on) ·
72 to 117 gm/sec (EGR off) |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Start the engine, turn off all accessory switches and warm up the engine until the engine coolant temperature stabilizes.
Enter the following menus: Powertrain / Engine / Data List / NOx Corrected Density B1S1
| Tester Display |
|---|
| NOx Corrected Density B1S1 |
Maintain the maximum possible engine speed under no load for 10 seconds and check the NOx Corrected Density B1S1 value.
50 ppm or more
When the No. 1 nitrogen oxides sensor output deviates toward the low side, the NOx purification rate decreases.
Normal output is approximately 100 ppm at the maximum possible engine speed under no load.
If the output does not exceed 50 ppm at the maximum possible engine speed under no load, the output of the No. 1 nitrogen oxides sensor is decreased.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
If there are deposits around the urea injector, injection may be inhibited, reducing purification performance.
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Enter the following menus: Powertrain / Engine / Active Test / Reductant Pump Check (Backward).
| Tester Display |
|---|
| Reductant Pump Check (Backward) |
Perform the Active Test.
Enter the following menus: Powertrain / Engine / Active Test / Reductant Purge.
| Tester Display |
|---|
| Reductant Purge |
Perform the Active Test.
Perform the Reductant Purge to draw the urea solution back into the urea tank sub-assembly from the urea injector set.
After performing the Active Test, remove the urea injector set from the front exhaust pipe assembly.
Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA INJECTOR>REMOVAL
Do not disconnect the urea injector from the urea tube with heater assembly.
| *1 | Front Exhaust Pipe Assembly |
| *a | Exhaust Pipe Connection Area to Check |
Check that there is no white matter deposited by urea solution on the connection area of the front exhaust pipe.
After checking for deposits, use a cover, etc., to prevent foreign matter from entering the front exhaust pipe.
| Result | Proceed to |
|---|---|
| No white matter is deposited by urea solution on connection area of front exhaust pipe | A |
| White matter is deposited by urea solution on connection area of front exhaust pipe | B |
A
B
If there is a malfunction in the urea injector set, NOx purification performance will be reduced.
Use a cover, etc., to prevent foreign matter from entering the front exhaust pipe where the urea injector set was removed.
Enter the following menus: Powertrain / Engine / Active Test / Reductant Injection Valve.
| Tester Display |
|---|
| Reductant Injection Valve |
Perform the Active Test and check that operation sounds can be heard from the urea injector set.
Sound of urea injector set operation can be heard (a ticking sound).
Even after checking is complete, do not install the urea injector removed from the front exhaust pipe yet.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Enter the following menus: Powertrain / Engine / Utility / Reductant Injection Valve Check.
| Tester Display |
|---|
| Reductant Injection Valve Check |
Execute the Reductant Injection Valve Check and check the injection condition of the urea injector set.
This test performs operations from urea solution refueling up to injection.
The pressure inside the pipe may increase during urea solution refueling, intermittently opening the urea injector set and causing urea solution to leak out.
If the urea injector set becomes stuck open during urea solution refueling, once this test starts, intermittent injections will not occur and urea solution will leak out.
Urea solution is intermittently injected by the urea injector set.
| *1 | Urea Injector Set | *2 | Spray Hole |
| *a | Urea injector set normal | *b | Urea injector set abnormal |
| Result | Proceed to |
|---|---|
| Urea injector set normal | A |
| Urea injector set abnormal | B |
Even after checking is complete, do not install the urea injector removed from the front exhaust pipe yet.
Wash off any matter deposited by the urea solution.
Do not damage the urea injector set when washing it.
Make sure to leave the connector connected when washing to prevent water from entering via the connector.
Sufficiently wipe the area so that no urea solution remains on the flange sealing surface.
After completing work, check that 3 streams of liquid are sprayed from the urea injector set.
A
B
When the No. 1 nitrogen oxides sensor output deviates toward the low side, the NOx purification rate decreases.
When the No. 2 nitrogen oxides sensor output deviates toward the high side, the NOx purification rate decreases.
Check that the ignition switch is off.
Use an air blow gun to blow air from the mounting hole of the urea injector set toward the No. 1 nitrogen oxides sensor and No. 2 nitrogen oxides sensor, expelling remaining NOx in the exhaust pipe.
Install the urea injector set.
Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA INJECTOR>INSTALLATION
Turn the ignition switch to ON and turn the GTS on.
Enter the following menus: Powertrain / Engine / Utility / NOx Sensor Check.
| Tester Display |
|---|
| NOx Sensor Check |
Perform the NOx Sensor Check.
Check the "NOx Density B1S1" and "NOx Density B1S2" output values.
Below approximately 20 ppm
Blowing air expels the NOx in the exhaust pipe. Therefore, if a large volume of NOx is detected, the sensor may be malfunctioning.
| Result | Proceed to |
|---|---|
| Both "NOx Density B1S1" and "NOx Density B1S2" values are normal. | A |
| "NOx Density B1S1" is abnormal. | B |
| "NOx Density B1S2" is abnormal. | C |
| Both "NOx Density B1S1" and "NOx Density B1S2" values are abnormal. | D |
A
B
C
D
Connect the GTS to the DLC3.
Clear the DTCs.
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON and turn the GTS on.
Start the engine and warm it up until the engine coolant temperature reaches 75°C (167°F) or higher.
Enter the following menus: Powertrain / Engine / Utility / PM Regenerate Mode.
| Tester Display |
|---|
| PM Regenerate Mode |
Enter PM Regenerate Mode.
Be careful of the exhaust pipe and surrounding areas, as they become extremely hot when performing PM forced regeneration control.
Before performing PM forced regeneration control, check that the atmospheric pressure is 94 kPa (705 mmHg, 27.8 in.Hg) or higher, and the ambient temperature is 0°C (32°F) or higher.
If PM forced regeneration control is stopped before it finishes, perform PM forced regeneration control again after repairing malfunctions to complete the procedure.
Enter the following menus: Powertrain / Engine / Data List / Diesel Exhaust / NOx Corrected Density B1S2 and SCR Temperature.
| Tester Display |
|---|
| NOx Corrected Density B1S2 |
| SCR Temperature |
After entering PM Regenerate Mode, press the snapshot button and record the data.
PM forced regeneration control takes 15 to 40 minutes to finish.
The time it takes to complete PM forced regeneration control changes depending on "PM Accumulation Ratio Bank 1" and vehicle operating conditions.
If the value of "Catalyst Differential Pressure Bank 1" increases too much during PM forced regeneration control, the fail-safe function activates and PM forced regeneration control is stopped.
Perform PM forced regeneration control until the display on the multi-information display turns off.
If actions such as depressing the accelerator pedal or clutch pedal or operating the DPF switch, etc. are performed during PM forced regeneration, PM forced regeneration stops. If PM forced regeneration stops, it is necessary to perform it again.
PM forced regeneration control is not complete until the display on the multi-information display turns off.
Check "NOx Corrected Density B1S2" when the "SCR Temperature" drops to approximately 340°C (644°F) according to the recorded data (snapshot).
50 ppm or less
If the value is above 50 ppm, replace the front exhaust pipe assembly, as it may be expelling ammonia.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Replace the front exhaust pipe assembly.
Click hereEngine / Hybrid System>1GD-FTV (INTAKE / EXHAUST)>EXHAUST PIPE>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Connect the GTS to the DLC3.
Clear the DTCs.
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON and turn the GTS on.
Start the engine and warm it up until the engine coolant temperature reaches 75°C (167°F) or higher.
Enter the following menus: Powertrain / Engine / Utility / PM Regenerate Mode.
| Tester Display |
|---|
| PM Regenerate Mode |
Enter PM Regenerate Mode.
Be careful of the exhaust pipe and surrounding areas, as they become extremely hot when performing PM forced regeneration control.
Before performing PM forced regeneration control, check that the atmospheric pressure is 94 kPa (705 mmHg, 27.8 in.Hg) or higher, and the ambient temperature is 0°C (32°F) or higher.
If PM forced regeneration control is stopped before it finishes, perform PM forced regeneration control again after repairing malfunctions to complete the procedure.
Enter the following menus: Powertrain / Engine / Data List / Diesel Exhaust / NOx Corrected Density B1S2 and SCR Temperature.
| Tester Display |
|---|
| NOx Corrected Density B1S2 |
| SCR Temperature |
After entering PM Regenerate Mode, press the snapshot button and record the data.
PM forced regeneration control takes 15 to 40 minutes to finish.
The time it takes to complete PM forced regeneration control changes depending on "PM Accumulation Ratio Bank 1" and vehicle operating conditions.
If the value of "Catalyst Differential Pressure Bank 1" increases too much during PM forced regeneration control, the fail-safe function activates and PM forced regeneration control is stopped.
Perform PM forced regeneration control until the display on the multi-information display turns off.
If actions such as depressing the accelerator pedal or clutch pedal or operating the DPF switch, etc. are performed during PM forced regeneration, PM forced regeneration stops. If PM forced regeneration stops, it is necessary to perform it again.
PM forced regeneration control is not complete until the display on the multi-information display turns off.
Check "NOx Corrected Density B1S2" when the "SCR Temperature" drops to approximately 340°C (644°F) according to the recorded data (snapshot).
50 ppm or less
| Proceed to |
|---|
| NEXT |
NEXT
Replace the No. 1 nitrogen oxides sensor.
Click hereEngine / Hybrid System>1GD-FTV (ENGINE CONTROL)>NITROGEN OXIDES SENSOR>REMOVAL
Perform "A/F Sensor Compensation Reset" after replacing the No. 1 nitrogen oxides sensor.
| Proceed to |
|---|
| NEXT |
NEXT
Replace the No. 2 nitrogen oxides sensor.
Click hereEngine / Hybrid System>1GD-FTV (ENGINE CONTROL)>NITROGEN OXIDES SENSOR>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Replace the urea injector set.
Click hereEngine / Hybrid System>1GD-FTV (EMISSION CONTROL)>UREA INJECTOR>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Replace the No. 1 nitrogen oxides sensor.
Click hereEngine / Hybrid System>1GD-FTV (ENGINE CONTROL)>NITROGEN OXIDES SENSOR>REMOVAL
Perform "A/F Sensor Compensation Reset" after replacing the No. 1 nitrogen oxides sensor.
Replace the No. 2 nitrogen oxides sensor.
Click hereEngine / Hybrid System>1GD-FTV (ENGINE CONTROL)>NITROGEN OXIDES SENSOR>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Clean any deposits from communicating portions of the front exhaust pipe.
After washing, make sure to wipe off the flange surface so that no urea solution remains.
| Proceed to |
|---|
| NEXT |
NEXT
Replace the No. 1 nitrogen oxides sensor.
Click hereEngine / Hybrid System>1GD-FTV (ENGINE CONTROL)>NITROGEN OXIDES SENSOR>REMOVAL
Perform "A/F Sensor Compensation Reset" after replacing the No. 1 nitrogen oxides sensor.
| Proceed to |
|---|
| NEXT |
NEXT
Replace the mass air flow meter sub-assembly.
Click hereEngine / Hybrid System>1GD-FTV (ENGINE CONTROL)>MASS AIR FLOW METER>REMOVAL
Before replacing the mass air flow meter sub-assembly, check the connections of the wire harness and connectors. If there is any abnormality, replace or repair the wire harness or connector.
| Proceed to |
|---|
| NEXT |
NEXT
Diagnose relevant DTCs.
Repair any malfunctioning parts indicated by related DTCs.
| Proceed to |
|---|
| NEXT |
NEXT