B2343 Position Initialization Incomplete
Diagnostic trouble codes · Vehicles built Aug 2008 – Jun 2010
Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010
DESCRIPTION
This DTC is output when the sliding roof drive gear sub-assembly (sliding roof control ECU) has not been initialized.| DTC No. |
DTC Detection Condition |
Trouble Area |
| B2343 |
Sliding roof drive gear sub-assembly (sliding roof control ECU) has not been initialized |
|
WIRING DIAGRAM
Refer to DTC B2341 (Click here).INSPECTION PROCEDURE
| 1. INITIALIZE SLIDING ROOF DRIVE GEAR SUB-ASSEMBLY (SLIDING ROOF CONTROL ECU) |
Check that the sliding roof drive gear sub-assembly (sliding roof control ECU) can be initialized (Click here).
- OK:
- Sliding roof drive gear sub-assembly (sliding roof control ECU) can be initialized.
|
|
||||
| OK | |
| 2. CHECK SLIDING ROOF FUNCTION |
Check the auto operation with the OPEN, CLOSE, UP and DOWN switches (Click here).
- OK:
- Auto operation operates normally with OPEN, CLOSE, UP and DOWN switches.
|
|
||||
| OK | |
| 3. RECHECK FOR DTC |
Delete the DTCs (Click here).
Recheck for DTCs (Click here).
- HINT:
- If DTCs are detected frequently, replace the ECU.
- OK:
- DTC is not output.
|
|
||||
| OK | ||
| ||
| 4. CHECK WIRE HARNESS (SLIDING ROOF CONTROL ECU - ROOF CONSOLE BOX ASSEMBLY) |
Disconnect the Q12 and Q1 connectors.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
Q12-2 (E) - Q1-2 (GND)
Always
Below 1 Ω
Q12-7 (OPN) - Q1-4 (OPN)
Always
Below 1 Ω
Q12-8 (DWN) - Q1-5 (DOWN)
Always
Below 1 Ω
Q12-9 (CLS) - Q1-3 (CLS)
Always
Below 1 Ω
Q12-10 (UP) - Q1-6 (UP)
Always
Below 1 Ω
Q1-3 (CLS) - Body ground
Always
10 kΩ or higher
Q1-4 (OPN) - Body ground
Always
10 kΩ or higher
Q1-2 (GND) - Body ground
Always
Below 1 Ω
Q1-5 (DOWN) - Body ground
Always
10 kΩ or higher
Q1-6 (UP) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | |
| 5. INSPECT ROOF CONSOLE BOX ASSEMBLY (SLIDING ROOF SWITCH ASSEMBLY) |
Remove the roof console box assembly.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Switch Position
Specified Condition
Q1-3 (CLS) - Q1-2 (GND)
CLOSE
Below 100 Ω
Q1-4 (OPN) - Q1-2 (GND)
OPEN
Below 100 Ω
Q1-5 (DOWN) - Q1-2 (GND)
DOWN
Below 100 Ω
Q1-6 (UP) - Q1-2 (GND)
UP
Below 100 Ω
Q1-3 (CLS) - Q1-2 (GND)
OPEN
1 kΩ or higher
Q1-4 (OPN) - Q1-2 (GND)
CLOSE
1 kΩ or higher
Q1-5 (DOWN) - Q1-2 (GND)
UP
1 kΩ or higher
Q1-6 (UP) - Q1-2 (GND)
DOWN
1 kΩ or higher
|
|
||||
| OK | ||
| ||