DTC Code
| INF Code
| DTC Detection Condition
| Trouble Area
|
C1241/41
| 81
| System 1 is under the following conditions when the power switch is on (IG):
- Linear solenoid cannot receive enough current (brake is applied).
- BS1 voltage is less than 8.9 V for at least 3 seconds (brake is not applied).
- 12 V power source voltage inside ECU is less than 8.5 V when main relay is opened or VCM voltage is less than 4.7 V or 5 V or more for at least 0.05 seconds.
| - Auxiliary battery
- ABS NO. 1 relay
- ABS NO. 1 relay circuit
- Brake control power supply (Capacitor)
- Hybrid control system (Charging circuit)
- Skid control ECU
|
↑
| 82
| System 2 is under the following conditions when the power switch is on (IG):
- Linear solenoid cannot receive enough current (brake is applied).
- BS2 voltage is less than 8.9 V for at least 3 seconds (brake is not applied).
- 12 V power source voltage inside ECU is less than 8.5 V when main relay is opened or VCM voltage is less than 4.7 V or 5.3 V or more for at least 0.05 seconds.
| - Auxiliary battery
- ABS NO. 2 relay
- ABS NO. 2 relay circuit
- Brake control power supply (Capacitor)
- Hybrid control system (Charging circuit)
- Skid control ECU
|
↑
| 83
| Capacitor mode signal is received from brake control power supply for 3 seconds or more when the power switch is on (IG).
| - Auxiliary battery
- Brake control power supply (Capacitor)
- Hybrid control system (Charging circuit)
|
↑
| 84
| ABS is requested to operate when the power source voltage of the main relay system is dropping.
| - ABS NO. 1 relay
- ABS NO. 1 relay circuit
- ABS NO. 2 relay
- ABS NO. 2 relay circuit
- Brake control power supply (Capacitor)
- Hybrid control system (Charging circuit)
- Skid control ECU
|
C1242/42
| 87
| The power supply voltage is not applied to the IG1 terminal, power supply voltage is applied to the IG2 terminal, and +BI1 terminal voltage is 9.5 V or more for 4 seconds or more.
| - Auxiliary battery
- IG1 power source circuit
- Hybrid control system (Charging circuit)
- Skid control ECU
|
↑
| 88
| The power supply voltage is applied to the IG1 terminal, power supply voltage is not applied to the IG2 terminal, and +BI1 terminal voltage is 9.5 V or more for 4 seconds or more.
| - Auxiliary battery
- IG2 power source circuit
- Hybrid control system (Charging circuit)
- Skid control ECU
|