DTC P0A78-284 Drive Motor "A" Inverter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A78 | 284 | Motor inverter fail signal detection (overheating) |
|
| Related DTCs | P0A78 (INF 284): Motor inverter / MFIV detection (overheat malfunction) |
| Required sensors / components | Motor inverter |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the DTCs listed are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| Motor inverter | Overheated |
| Motor inverter | DTC P0A78 (INF 284) is not detected |
| 1.CHECK DTC OUTPUT (HV) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P0A78-284 only is output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A05-776 | Motor Electronics Coolant Pump Control Circuit / Open |
| P0A1A (all INF codes) *1 | Generator Control Module |
| P0A1B (all INF codes) *1 | Drive Motor "A" Control Module |
| P0A1C (all INF codes) *1 | Drive Motor "B" Control Module |
| P0A1D (all INF codes) *1 | Hybrid Powertrain Control Module |
| P0A2B-248, 250 | Drive Motor "A" Temperature Sensor Circuit Range / Performance |
| P0A2C-247 | Drive Motor "A" Temperature Sensor Circuit Low |
| P0A2D-249 | Drive Motor "A" Temperature Sensor Circuit High |
| P0A37-258, 260 | Generator Temperature Sensor Circuit Range / Performance |
| P0A38-257 | Generator Temperature Sensor Circuit Low |
| P0A39-259 | Generator Temperature Sensor Circuit High |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A45-669 | Drive Motor "B" Position Sensor Circuit |
| P0A46-671 | Drive Motor "B" Position Sensor Circuit Range / Performance |
| P0A47-670 | Drive Motor "B" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A55-687 | Drive Motor "B" Current Sensor Circuit |
| P0A60 (all INF codes) *1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes) *1 | Drive Motor "A" Phase W Current |
| P0A69 (all INF codes) *1 | Drive Motor "B" Phase V Current |
| P0A6C (all INF codes) *1 | Drive Motor "B" Phase W Current |
| P0A72 (all INF codes) *1 | Generator Phase V Current |
| P0A75 (all INF codes) *1 | Generator Phase W Current |
| P0A78-266, 267, 272, 278, 279, 280, 282, 283, 285, 286, 287, 304, 305, 306, 503, 504, 505, 506, 508, 510, 523, 586 | Drive Motor "A" Inverter Performance |
| P0A79 (all INF codes) *1 | Drive Motor "B" Inverter Performance |
| P0A7A (all INF codes) *1 | Generator Inverter Performance |
| P0A90-251, 509 | Drive Motor "A" Performance |
| P0A92-261, 521 | Hybrid Generator Performance |
| P0A93-346, 347 | Inverter Cooling System Performance |
| P0A94 (all INF codes) *1 | DC / DC Converter Performance |
| P0AA6 (all INF codes) *1 | Hybrid Battery Voltage System Isolation Fault |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0AE6-225 | Hybrid Battery Positive Contactor Circuit Stuck Open |
| P0AE7-224 | Hybrid Battery Precharge Contactor Control Circuit High |
| P0AEE-276, 277 | Motor Inverter Temperature Sensor "A" Circuit Range / Performance |
| P0AEF-275 | Drive Motor Inverter Temperature Sensor "A" Circuit Low |
| P0AF0-274 | Drive Motor Inverter Temperature Sensor "A" Circuit High |
| P0AF3-675, 676 | Sensor of Rear Motor Inverter Temperature |
| P0AF4-673 | Open or Short to GND in Rear Motor Inverter Temperature Sensor |
| P0AF5-674 | Short to B+ in Rear Motor Inverter Temperature Sensor |
| P3000-388, 389, 603 | HV Battery Malfunction |
| P3004 (all INF codes) *1 | Power Cable Malfunction |
| P3221-314, 315 | Generator Inverter Temperature Sensor Circuit Range / Performance |
| P3226-562, 563 | Power Cable Malfunction |
|
| ||||
| A | |
| 2.CHECK QUANTITY OF HV COOLANT |
![]() |
Check the coolant level in the inverter reserve tank.
Check for coolant leaks.
| Result | Proceed to |
| Coolant leaks are not evident. A sufficient amount of coolant remains in the inverter reserve tank. | A |
| Coolant leaks are not evident. No coolant remains in the inverter reserve tank. | B |
| Coolant leaks are evident | C |
|
| ||||
|
| ||||
| A | |
| 3.CHECK COOLANT HOSE |
![]() |
Check if the hoses of the cooling system are kinked or clogged.
|
| ||||
| OK | |
| 4.CHECK CONNECTOR CONNECTION CONDITION (WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY CONNECTOR) |
![]() |
Check the connection of the water pump with motor and bracket assembly connector.
|
| ||||
| OK | |
| 5.PERFORM ACTIVE TEST USING TECHSTREAM (WATER PUMP) |
Turn the the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.
Perform the "Activate the Water Pump" active test for at least 1 minute.
![]() |
Check that there are ripples in the coolant in the inverter reserve tank.
|
| ||||
| OK | |
| 6.PERFORM ACTIVE TEST USING TECHSTREAM (COOLING FAN) |
Select the following menu items: Powertrain / Engine and ECT / Active Test / Control the Electric Cooling Fan.
Perform the "Control the Electric Cooling Fan" active test.
|
| ||||
| OK | |
| 7.CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR) |
![]() |
Check the connections of all hybrid vehicle control ECU connectors.
|
| ||||
| OK | |
| 8.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR) |
Turn the power switch off.
Remove the service plug grip (Click here).
Remove the inverter cover (Click here).
![]() |
Check the connections of the MG ECU connectors.
|
| ||||
| OK | |
| 9.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2) |
Check that the service plug grip is not installed.
![]() |
Disconnect the three-phase AC cable for MG2 from the inverter with converter assembly.
![]() |
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| U - V | Power switch off (68°F (20°C)) | 52.4 to 58.4mΩ |
| V - W | Power switch off (68°F (20°C)) | 50.5 to 56.5 mΩ |
| W - U | Power switch off (68°F (20°C)) | 50.5 to 56.5 mΩ |
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 68°F (20°C).
Calculate the difference between the maximum and minimum resistance.
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| MG2 U terminal - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| MG2 V terminal - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| MG2 W terminal - Body ground and shield ground | Power switch off | 100 MΩ or higher |
|
| ||||
| OK | |
| 10.CHECK HARNESS AND CONNECTOR (MG ECU - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
![]() |
Disconnect the B49 connector from the MG ECU.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B49-13 (MRF) - Body ground | Power switch on (IG) | Below 1 V |
| B49-23 (MRFG) - Body ground | Power switch on (IG) | Below 1 V |
| B49-21 (MSN) - Body ground | Power switch on (IG) | Below 1 V |
| B49-20 (MSNG) - Body ground | Power switch on (IG) | Below 1 V |
| B49-19 (MCS) - Body ground | Power switch on (IG) | Below 1 V |
| B49-18 (MCSG) - Body ground | Power switch on (IG) | Below 1 V |
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B49-13 (MRF) - B49-23 (MRFG) | Power switch off | 7.65 to 10.2 Ω |
| B49-21 (MSN) - B49-20 (MSNG) | Power switch off | 12.6 to 16.8 Ω |
| B49-19 (MCS) - B49-18 (MCSG) | Power switch off | 12.6 to 16.8 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B49-13 (MRF) or B49-23 (MRFG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| B49-21 (MSN) or B49-20 (MSNG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| B49-19 (MCS) or B49-18 (MCSG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
|
| ||||
| OK | |
| 11.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | ||
| ||
| 12.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | |
| 13.CHECK MOTOR RESOLVER |
![]() |
Disconnect the B54 motor resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B54-1 (MRF) - B54-4 (MRFG) | Power switch off | 7.65 to 10.2 Ω |
| B54-2 (MSN) - B54-5 (MSNG) | Power switch off | 12.6 to 16.8 Ω |
| B54-3 (MCS) - B54-6 (MCSG) | Power switch off | 12.6 to 16.8 Ω |
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B54-1 (MRF) - B54-2 (MSN) | Power switch off | 10 MΩ or higher |
| B54-1 (MRF) - B54-3 (MCS) | Power switch off | 10 MΩ or higher |
| B54-2 (MSN) - B54-3 (MCS) | Power switch off | 10 MΩ or higher |
| B54-4 (MRFG) - B54-5 (MSNG) | Power switch off | 10 MΩ or higher |
| B54-4 (MRFG) - B54-6 (MCSG) | Power switch off | 10 MΩ or higher |
| B54-5 (MSNG) - B54-6 (MCSG) | Power switch off | 10 MΩ or higher |
| Each terminal listed above - Transaxle housing | Power switch off | 10 MΩ or higher |
|
| ||||
| OK | ||
| ||
| 14.CHECK FUSE (INV-W/P) |
![]() |
Check if there is an open circuit in the fuse (INV-W/P) in the No. 2 engine room relay block.
|
| ||||
| OK | |
| 15.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - WATER PUMP) |
![]() |
Turn the power switch off.
Disconnect the D35 connector from the hybrid vehicle control ECU.
Disconnect the A52 water pump with motor and bracket assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D35-29 (NIWP) - A52-1 (NWP) | Power switch off | Below 1 Ω |
| D35-23 (IWP) - A52-2 (SWP) | Power switch off | Below 1 Ω |
| A52-3 (GND) - Body ground | Power switch off | Below 1 Ω |
| INV-W/P fuse terminal 2 - A52-4 (+BWP) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| D35-29 (NIWP) or A52-1 (NWP) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| D35-23 (IWP) or A52-2 (SWP) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| INV-W/P fuse terminal 2 or - A52-4 (+BWP) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||