Home › HYBRID SYSTEM · P310 › HYBRID VEHICLE CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A93-346    Inverter Cooling System Performance

DTC    P0A93-347    Inverter Cooling System Performance

for Preparation Click here


DESCRIPTION

The inverter converts the high-voltage direct current of the HV battery into the alternating current for MG2, MG1, and MGR. The inverter generates heat during the conversion process, and this heat could damage the inverter if the cooling system is malfunctioning. Therefore, similar to MG2 and MG1, the inverter is cooled by a special cooling system consisting of an electric water pump, the cooling fan, and a radiator. This cooling system is independent of the engine cooling system. The hybrid vehicle control ECU monitors the electric water pump, cooling fan, and cooling system, and detects the following malfunctions.

A174884


DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A93
346
Inverter cooling system malfunction (HV cooling malfunction)
  1. Wire harness or connector
  2. Inverter cooling system
  3. Water pump with motor and bracket assembly
  4. Cooling fan system
  5. Inverter with converter assembly (MG ECU)
  6. Hybrid vehicle control ECU
  7. INV-W/P fuse
347
Inverter cooling system malfunction (radiator fan malfunction)

MONITOR DESCRIPTION

If the hybrid vehicle control ECU detects a malfunction of the electric water pump, fan or radiator, the ECU will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P0A93 (INF 346): Inverter cooling system performance / HV coolant malfunction
P0A93 (INF 347): Inverter cooling system performance / Radiator FAN malfunction
Required sensors / components
Water pump, radiator fan, inverter, boost converter, DC/DC converter
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the DTCs listed are not present
TMC's intellectual property
Other conditions belong to TMC's intellectual property
-

TYPICAL MALFUNCTION THRESHOLDS


TMC's intellectual property
-

COMPONENT OPERATING RANGE


Water pump, radiator fan
DTC P0A93 (INF 346/347) is not detected

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals. After waiting for 5 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

HINT:
Waiting for at least 5 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

1.CHECK DTC OUTPUT (HV)
  1. Turn the power switch on (IG) and wait for 10 seconds or more.

  1. Turn the power switch off.

  1. Connect Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A93-346 or 347 only is output.
    A
    Any of the following DTCs are also output.
    B


    DTC No.
    Relevant Diagnosis
    P0A05-776
    Motor Electronics Coolant Pump Control Circuit / Open

    HINT:
    P0A93-346 and P0A93-347 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.



B
GO TO DTC CHART (Click here)
A


2.CHECK QUANTITY OF HV COOLANT


    A169560E01
  1. Check the coolant level in the inverter reserve tank.

  1. Check for coolant leaks.

    Result:
    Result
    Proceed to
    Coolant leaks are not evident. A sufficient amount of coolant remains in the inverter reserve tank.
    A
    Coolant leaks are not evident. No coolant remains in the inverter reserve tank.
    B
    Coolant leaks are evident
    C

    HINT:
    After repairing the coolant leaks and adding coolant, perform the "Activate the Water Pump" active test (HV ECU active test item) and the "Control the Electric Cooling Fan" active test (ENHANCED OBDII active test item) and make sure that there are no malfunctions.



B
ADD HV COOLANT

C
CHECK FOR COOLANT LEAKS AND ADD COOLANT
A


3.CHECK COOLANT HOSE


    A105138E03
  1. Check if the hoses of the cooling system are kinked or clogged.

    OK:
    The hoses of the cooling system are not kinked or clogged.



NG
CORRECT THE PROBLEM
OK


4.CHECK CONNECTOR CONNECTION CONDITION (WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY CONNECTOR)


    A174885
  1. Check the connection of the water pump with motor and bracket assembly connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


5.PERFORM ACTIVE TEST USING TECHSTREAM (WATER PUMP)
  1. Turn the the power switch on (IG).

  1. Select the following menu items: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.

  1. Perform the "Activate the Water Pump" active test for at least 1 minute.



    A169560E01
  1. Check that there are ripples in the coolant in the inverter reserve tank.

    OK:
    There are ripples in the coolant in the inverter reserve tank as long as the active test is being performed.

    NOTICE:
    In addition to the active test, the water pump with motor and bracket assembly will also operate with the power switch on (READY). However, the water pump with motor and bracket assembly will not operate for 20 seconds after the power switch is turned on (READY).

    HINT:
    The water pump with motor and bracket assembly will also operate in inspection mode.



NG
Go to step 7
OK


6.PERFORM ACTIVE TEST USING TECHSTREAM (COOLING FAN)
  1. Select the following menu items: Powertrain / Engine and ECT / Active Test / Control the Electric Cooling Fan.

  1. Perform the "Control the Electric Cooling Fan" active test.

    OK:
    The cooling fan rotates.



NG
CHECK COOLING FAN SYSTEM (Click here)
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

7.CHECK FUSE (INV-W/P)


    A174902E03
  1. Check if there is an open circuit in the fuse (INV-W/P) in the No. 2 engine room relay block.

    OK:
    There is no open circuit in the fuse (INV-W/P).

    HINT:
    If the result is NG, replace the fuse (INV-W/P) with a new one.



NG
REPLACE FUSE (INV-W/P)
OK


8.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - WATER PUMP)


    A184421E04
  1. Turn the power switch off.

  1. Disconnect the D35 connector from the hybrid vehicle control ECU.

  1. Disconnect the A52 water pump with motor and bracket assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Switch Condition
    Specified Condition
    D35-29 (NIWP) - A52-1 (NWP)
    Power switch off
    Below 1 Ω
    D35-23 (IWP) - A52-2 (SWP)
    Power switch off
    Below 1 Ω
    A52-3 (GND) - Body ground
    Power switch off
    Below 1 Ω
    INV-W/P fuse terminal 2 - A52-4 (+BWP)
    Power switch off
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Switch Condition
    Specified Condition
    D35-29 (NIWP) or A52-1 (NWP) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    D35-23 (IWP) or A52-2 (SWP) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    INV-W/P fuse terminal 2 or - A52-4 (+BWP) - Body ground and other terminals
    Power switch off
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9.CHECK HYBRID VEHICLE CONTROL ECU
  1. Connect the hybrid vehicle control ECU connector.

  1. Turn the power switch on (IG).



    A174222E24
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    D35-23 (IWP) - B3-5 (E1)
    Power switch on (IG)
    Below 3.5 V



NG
Go to step 11
OK


10.INSPECT HYBRID VEHICLE CONTROL ECU
  1. Turn the power switch on (READY).



    A174222E25
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    D35-23 (IWP) - B3-5 (E1)
    Power switch on (READY)
    9 to 15.5 V



NG
REPLACE HYBRID VEHICLE CONTROL ECU (Click here)
OK

REPLACE WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY (Click here)  

11.INSPECT WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY
  1. Turn the power switch off.



    A174231E06
  1. Disconnect the D35 hybrid vehicle control ECU connector.

  1. Turn the power switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    D35-23 (IWP) - B3-5 (E1)
    Power switch on (IG)
    9 to 14 V



NG
REPLACE WATER PUMP WITH MOTOR AND BRACKET ASSEMBLY (Click here)
OK

REPLACE HYBRID VEHICLE CONTROL ECU (Click here)